China factories

China factory - ShenzhenYijiajie Electronic Co., Ltd.

ShenzhenYijiajie Electronic Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In
China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In

  1. China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In
  2. China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In
  3. China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In
  4. China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In
  5. China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor Electrochemical Gas Sensor Widely Used In

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time 3-5work days
Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Response Time (T90) <15 s (air to 100% O2)
Baseline Offset <200 μV
Linearity Linear 0% to 100% O2 (See Note1)
Model Number MOX1 MOX-1

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Delivery Time 3-5work days
Operating Principle Partial pressure electrochemical Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2 Response Time (T90) <15 s (air to 100% O2)
Baseline Offset <200 μV Linearity Linear 0% to 100% O2 (See Note1)
Model Number MOX1 MOX-1

                                                                                  MOX1 Oxygen Sensor

 

 

Document Purpose:
The purpose of this document is to present the performance specification of the MOX1 oxygen gas sensor.
This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

 

 

Important Note:

Connection should be made via recommended mating parts only. Soldering to the sensor will damage it and invalidate the warranty.
For further information on the external load resistance and connection to the recommended mating part, please see Operating Principle OP-04 or contact City Technology.
All performance data is based on measurements made with cylinder gases using a flow rate of 100 mls/min. Conditions at 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, contact City Technology.
Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.

 

Poisoning:
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

 

Intended Use:
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

 

Stabilisation Time:
Allow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturers instructions

 

 

Cleaning and Sterilisation:
In case of contamination the sensor may be cleaned with distilled water and allowed to dry naturally. The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or hydrogen peroxide.

 

Calibration Interval:
These sensors are designed to have minimal drift over their useful lifetime. For maximum accuracy however they should be calibrated before each use.

 

Temperature Compensation <2% O2 equivalent (0°C to 40°C)
External Load Resistor 10 kΩ minimum (See Important Note)
Connector 3-pin Molex Header: (Molex 22-29-2031)
Housing Material White ABS
Weight 39 g (nominal)

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement