Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time | 3-5work days |
Measurement Range | 0.5 ppm H2S to 200 ppm H2S |
Maximum Overload | 500 ppm |
Onboard Filter | None |
Sensitivity* | 175 nA/ppm ±35 nA/ppm |
T90 Response Time* | Typically < 30 seconds |
Recovery Time* (from 200 ppm to <4 ppm) | < 180 seconds |
Model Number | AC400-R00A-CIT |
View Detail Information
Explore similar products
H2S-AH Hydrogen Sulfide Sensor (High Current H2S Sensor) Is Used In Hydrogen
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 3-5work days |
Measurement Range | 0.5 ppm H2S to 200 ppm H2S | Maximum Overload | 500 ppm |
Onboard Filter | None | Sensitivity* | 175 nA/ppm ±35 nA/ppm |
T90 Response Time* | Typically < 30 seconds | Recovery Time* (from 200 ppm to <4 ppm) | < 180 seconds |
Model Number | AC400-R00A-CIT |
AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer
Document Purpose
The purpose of this document is to present the performance specification of the 1series 1H2S hydrogen sulfide gas sensor.
This document should be used in conjunction with the 1H2S Characterisation Note, the Operating Principles (OP08), and the Product Safety Datasheet (PSDS 5).
For guidance on sensor performance outside of these limits, please refer to the 1H2S Characterisation Note.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP08).
Poisoning
Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is
important that exposure to high concentrations of solvent vapours is avoided during 1) storage, 2) fitting into
instruments and 3) operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted.
Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic.
Baseline Offset* (in clean air) | < ±0.5 ppm H2S equivalent |
Baseline Shift (-40°C to 60°C) | < ±3 ppm H2S equivalent |
Repeatability* | < ±5% of measured value |
Linearity* (0 ppm H2S to 200 ppm H2S) | Linear ±5% |
Recommended Load Resistor | 5 Ω to 10 Ω |
Weight | < 5 g |
Outer Plastic Body Material | Modified PPO |
O-ring Material | FKM75 ±5 shore A |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se...
Get in touch with us
Leave a Message, we will call you back quickly!