Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 311/pcs/pre |
Delivery Time | 3-5work days |
Packaging Details | canned |
Typical Applications | Critical care anesthesia |
Operating Temperature Range | -20°C to +50°C |
Operating Pressure Range | 0.5 Bar to 2.0 Bar |
Operating Humidity Range | 0% to 99% RH non-condensing |
Long-Term Ouput Drift in 100% O2 | < 5% signal loss/year |
Recommended Storage Temperature | -10°C to +40°C |
Brand Name | CITY |
Model Number | MOX-3 MOX3 AA829-M10 |
Place of Origin | Britain |
View Detail Information
Explore similar products
2FO AA625-180 Air Oxygen Sensor Combustion Efficiency For Fixed Gas Detector
AO2 PTB-18.10 AA428-210 Gas Oxygen Sensor Partial Pressure Electrochemical O2
MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen
MAX250E R125P03-002 Electrochemical Dissolved Oxygen Sensor For Breathing
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 311/pcs/pre |
Delivery Time | 3-5work days | Packaging Details | canned |
Typical Applications | Critical care anesthesia | Operating Temperature Range | -20°C to +50°C |
Operating Pressure Range | 0.5 Bar to 2.0 Bar | Operating Humidity Range | 0% to 99% RH non-condensing |
Long-Term Ouput Drift in 100% O2 | < 5% signal loss/year | Recommended Storage Temperature | -10°C to +40°C |
Brand Name | CITY | Model Number | MOX-3 MOX3 AA829-M10 |
Place of Origin | Britain | ||
High Light | MOX3 Oxygen Gas Sensor ,Oxygen Gas Sensor AA829-M10 ,MOX-3 Oxygen Sensor |
Product Description:
MOX-3 MOX3 AA829-M10 Oxygen Gas sensor Oxygen Battery For Medical Devices
Features:
The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.
This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended Use
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.
Specifications:
Operating Principle | Partial pressure electrochemical |
Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 |
Response Time (T90)* | <15 s (air to 100% O2) |
Baseline Offset* | <200 μV |
Linearity | Linear 0% to 100% O2 |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States HONEYWELL pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV se...
Get in touch with us
Leave a Message, we will call you back quickly!