Payment Terms | L/C, D/A, D/P, , T/T, Western Union |
Supply Ability | 20,000 sets per month |
Delivery Time | 7-10 working days |
Packaging Details | carton/wooden case |
Input Frequency | 45~65Hz |
Max. Input Current | 20A |
Input Voltage | AC220V |
Application | outdoor telecom cabinet |
Output Voltage | DC48V |
Output Power | 6400W |
Brand Name | ESTEL |
Model Number | GPE48120C |
Certification | ISO9001, CE, 3C, FCC, TLC |
Place of Origin | Shenzhen, China (Mainland) |
View Detail Information
Explore similar products
19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module
6U Height Power Supply System ET4830000W Telecom Rectifier System
ET48300-005 Telecom Rectifier Module With Power Distribution And Battery
Microwave Communication GPE4890A Telecom Rectifier System / High Efficiency
Product Specification
Payment Terms | L/C, D/A, D/P, , T/T, Western Union | Supply Ability | 20,000 sets per month |
Delivery Time | 7-10 working days | Packaging Details | carton/wooden case |
Input Frequency | 45~65Hz | Max. Input Current | 20A |
Input Voltage | AC220V | Application | outdoor telecom cabinet |
Output Voltage | DC48V | Output Power | 6400W |
Brand Name | ESTEL | Model Number | GPE48120C |
Certification | ISO9001, CE, 3C, FCC, TLC | Place of Origin | Shenzhen, China (Mainland) |
High Light | dc rectifier system , rack mount rectifier |
120A DC Telecom Rectifier System , Single Phase / Three Phase Rectifier
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE48120C | Output Power: 6400W |
Product Name: Telecom Power System | Input Frequency 50Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 20A |
Installation Mode: 19” cabinet | Power Factor: 0.99 |
Application: outdoor telecom cabinet | Components: 4×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. System Configuration
The system consists of power distribution unit, rectifier module (from 1 set, up to 5 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution | Remark |
Standard | GPR4830A1 | GPM48R (With Ethernet Port) | AC power distribution: AC input is wire connection terminal; DC power distribution: battery MCB 100A×2; LVLD: 63A×2 32A×4 (MCB capacity optional) LVBD: 16A×2 (MCB capacity optional) | For details, please refer to the specifications of modules. |
2. Operating Principle
AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.
Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retains power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.
Environment | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Operating temperature | -25 | 55 | °C | When ≥55°C, decreased power output | |
Storage temperature | -40 | 80 | °C | ||
Humidity | 10 | 90 | % | Relative humidity without condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling | Forced cooling with fan |
Input | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 280 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Max. Input current | 20 | A | |||
Power factor | 0.99 | Rated load | |||
Input over voltage protection point | 285 | Vac | Automatically recoverable | ||
Input over voltage recovery point | 280 | Vac | Return difference ≥5V | ||
Input under voltage protection point | 85 | Vac | Automatically recoverable | ||
Input under voltage recovery point | 90 | Vac | Return difference ≥5V | ||
Input over current protection |
Output (Table 1) | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Output voltage | 42 | 53.5 | 58 | Vdc | Adjustable by monitor, tested in no load |
Output power | 6400 | W | 176~280VAC (rated power includes battery charging power plus load power) | ||
3200 | W | 90~175VAC input | |||
Output over voltage protection point | 58.5 | 61.5 | Vdc | Lock up | |
Output current limiting protection point | Output current limiting protection | ||||
Output short circuit protection | Long-term short circuit protection, automatically recoverable | ||||
Over temperature protection | Automatically recoverable in ambient temperature lower than 65°C | ||||
Battery power-down protection | Battery power-down protection | ||||
Battery polarities reversal connection protection | No damage on battery and power system | ||||
Voltage regulation accuracy | ±1 | % |
Output (Table 2) | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Temperature coefficient | ±0.2 | ‰/℃ | |||
Current sharing unbalance | ±5 | % | Within 50~100% load range | ||
Start-up/shut-down overshoot range | ±5 | % | Any module is removed when operating, (the load current should be less than total output current of working rectifier modules), the system output voltage fluctuates | ||
Dynamic response recovery time | 200 | uS | 25%~50%~25% load variation 50%~75%~50% load variation | ||
Dynamic response overshoot | ±5 | % | Rated output voltage, rated load current | ||
Efficiency | 90 | 91 | % | 220Vac input, rated output voltage, rated load current | |
83 | % | 110Vac input, rated output voltage, rated load current | |||
Start-up time | 3 | 8 | S | pre-current limiting is fitted with start-up output between rated start up input voltage and rated output voltage established period | |
Peak-peak noise voltage | 200 | mV |
Other Parameters | |
Item | Requirement |
Acoustic noise | ≤55dB(A) |
Smelling | any abnormal and poisonous smelling is not allowed |
Components | rated temperature of the electrolytic capacitor ≥105℃ |
Hot swappable | the rectifier module meets the hot-swappable requirement |
Mixed insertion | rectifier modules can be mixed insertion |
Ineffective separation | rectifier module can separate with system when it is ineffective |
Cooling | forced cooling by fan mounted on rectifier, face in, back out. The fan is mounted on rectifier front panel; can be disassembled. Fans include temperature control speed adjusting function. |
Insulation Rating | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Input-chassis | 4242 | Vdc | |||
Input-output | 2121 | Vdc | |||
Output-chassis | 750 | Vdc | |||
Insulating Resistance | In normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ |
4. Dimension
Mechanical specifications | |
Dimensions (mm) | as the following diagram |
Weight(kg) | ≤18kg (Inclusive of module) ≤10kg (Frame + Distribution, exclusive of module) |
Chassis connects with external electric through system interface board. As shown in figure below:
Power Distribution Instruction:
6. GPE48120C Distribution Frame
7. Application
(1) Small scale program controlled exchanger
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
(1) Adoption of active power factor compensation technology with factor >0.98
(2) Wide operating range of AC input voltage: 90~290Vac
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥91%
(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel output
(12) Embedded mounting
9. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
10. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
2002
Total Annual:
15 Million-20 Million
Employee Number:
101~200
Ecer Certification:
Verified Supplier
Introduction Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech... Introduction Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech...
Get in touch with us
Leave a Message, we will call you back quickly!