China factories

China factory - Tianjin Estel Electronic Science and Technology Co.,Ltd

Tianjin Estel Electronic Science and Technology Co.,Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 220VAC 400W Cooling Kiosk Air Conditioner 300W Heating Capacity With Remote
China 220VAC 400W Cooling Kiosk Air Conditioner 300W Heating Capacity With Remote

  1. China 220VAC 400W Cooling Kiosk Air Conditioner 300W Heating Capacity With Remote
  2. China 220VAC 400W Cooling Kiosk Air Conditioner 300W Heating Capacity With Remote

220VAC 400W Cooling Kiosk Air Conditioner 300W Heating Capacity With Remote

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, L/C,D/A, Western Union, Paypal, etc
Supply Ability 8,000 sets per month
Delivery Time 15-20 working days
Packaging Details Wooden case with pallets
Ingress Protection IP55
Input voltage AC220V±15% 50Hz
Cooling capacity L35/L35 400W
Heating capacity 300W
Weight 11kg
Refrigerant R134A
Brand Name ESTEL
Model Number EGA0400/A1
Certification ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin Shenzhen, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C,D/A, Western Union, Paypal, etc Supply Ability 8,000 sets per month
Delivery Time 15-20 working days Packaging Details Wooden case with pallets
Ingress Protection IP55 Input voltage AC220V±15% 50Hz
Cooling capacity L35/L35 400W Heating capacity 300W
Weight 11kg Refrigerant R134A
Brand Name ESTEL Model Number EGA0400/A1
Certification ISO9001, CE, 3C, FCC, TLC, IP55 Place of Origin Shenzhen, China (Mainland)
High Light electrical enclosure air conditioneroutdoor enclosure air conditionerRemote Monitor Kiosk Air Conditioner

 

Kiosk Air Conditioner 220VAC 400W Cooling Capacity With 300W Heating Capacity

 

 

1. Product Parameters

 

Type Parameters
Dimensions(Without flange) HWD 470*450*158mm
Weight 11 kg
Mounting method Door mounted
Working temperature -40℃ -55 ℃
Input voltage 220 VAC±15% ~/50Hz
Cooling capacity L35/L35 400 W

Rated Refrigerating input

power(L35/L35)

250W
Rated Refrigerating current (L35/L35) 1.1A
Heating capacity 300W
Airflow 240 m3/h
IP grade IP 55
Refrigerant R134A
Noise 60 dB(A)

 

2. Preparation And Installation

 

2.1 Removing package and checking

1. Please prepare installation tools: knife and scissors, and wear protective gloves.

2. Please remove wrapping film and packing belt, then remove the carton, take out the air

conditioner.

3. Please check the attachment list and accessory bags in the carton, check whether the air conditioner model is right .

2.2 Mechanical installation

Installation tool: Phillips screwdriver

Installation Steps:

1) Choose cut location on the cabinet according to the holing diagram, remove the shadow area and make the installation hole.

2) Make air conditioner flange close to cabinet door, Fix the air conditioner on the installation surface of the cabinet firmly with M5 screws.

3) Check whether air conditioner is installed levelly and firmly.

 

3 Product function

 

3.1 Cooling

When the temperature inside cabinet is higher than refrigeration starting temperature, it starts

refrigerating; when the temperature inside cabinet is lower than refrigeration stopping temperature, it

stops refrigerating.

 

3.2 Heating(Optional)

When the temperature inside cabinet is lower than heating starting temperature, it starts heating;when the temperature inside cabinet is higher than heating stopping temperature, it stops heating.

 

3.3 Remote monitor

Air conditioner has an RS485 communication interface, supporting MODBUS- RTU communication protocol.The air conditioner communicates with the upper monitor through the RS485 communication interface. Or users can check the air conditioner’s running state by viewing the display screen directly and change its running parameters.

 

3.4 The control of external fan (Optional)

According to the optional requirement, the external fan (Hydrogen discharge / emergency fan) automatically realizes cycle hydrogen discharging and emergency ventilation function.

Hydrogen discharge function(Optional):When hydrogen discharge cycle comes, air conditioner start the hydrogen discharge fan, the control switch closes.

Emergency ventilation function (Optional): When the temperature inside cabinet is higher than Emergency ventilation starting temperature, emergency ventilation fans run; when the temperature inside cabinet is lower than Emergency ventilation stopping temperature, emergency ventilation fans stop.

 

4. Product Pictures

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2002

  • Total Annual:

    15 Million-20 Million

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech... Introduction    Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and tech...

+ Read More

Get in touch with us

  • Reach Us
  • Tianjin Estel Electronic Science and Technology Co.,Ltd
  • 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
  • https://www.outdoortelecomcabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement