Packaging Details | CONTAINER ,WOODEN CASE |
Delivery Time | Negotiate |
Payment Terms | T/T, L/C |
Supply Ability | depend on the designing capacity |
fuel | oil and gas |
fuel oil consumption | 201g/kwh |
Place of Origin | WUXI , CHINA |
Brand Name | KANGWEI |
Certification | ISO IEC ASTM |
Model Number | According to the design and technical demand |
View Detail Information
Explore similar products
Light Fuel Oil / Heavy Fuel Oil Containerized Power Plant 20MW 400V 11KV 23KV
11000V Stationary / Land Diesel Gas Engine Power Plant CCS BV Certification
High Performance Genset Power Plant , HFO Fired Power Plant Environmentally
Customized HFO and diesel oil Genset Power Plant Water and air Cooling Generator
Product Specification
Packaging Details | CONTAINER ,WOODEN CASE | Delivery Time | Negotiate |
Payment Terms | T/T, L/C | Supply Ability | depend on the designing capacity |
fuel | oil and gas | fuel oil consumption | 201g/kwh |
Place of Origin | WUXI , CHINA | Brand Name | KANGWEI |
Certification | ISO IEC ASTM | Model Number | According to the design and technical demand |
High Light | Generator Power Plant ,Diesel Engine Power Plants |
1000KW-5000KW 400V - 11KV 650RPM 1000RPM MAN Engine Generator
HFO and diesel oil Genset Power Plant
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
GN8320 Stationary Generating Sets Main Specification |
||||||||||
Model |
2400GF |
2500GF |
||||||||
Rated power, KW |
2400 |
2500 |
||||||||
Overload , KW |
2640 |
2750 |
||||||||
Rated voltage, V |
400 |
415 |
3300 |
6300 |
10500 |
400 |
415 |
3300 |
6300 |
10500 |
Rated current , A |
4330 |
4174 |
525 |
275 |
165 |
4511 |
4348 |
547 |
172 |
286 |
Frequency , Hz |
50 |
50 |
||||||||
Power factor |
0.8 Lagging |
0.8 Lagging |
||||||||
Phase |
3 |
3 |
||||||||
Diesel engine |
GN832000ZD |
GN8320ZD |
||||||||
Rated power, KW |
2648 |
2795 |
||||||||
Rated rev, rpm |
750 |
750 |
||||||||
Alternator |
3 phase alternator |
|||||||||
voltage fluctuation rate% |
±1.0 |
|||||||||
Frequency fluctuation rate, % |
+12, -10 |
|||||||||
Stable voltage regulating rate, % |
3 |
|||||||||
Transient voltage regulating rate, % |
+12, -10 |
|||||||||
Stable Frequency fluctuation rate, % |
4
|
|||||||||
Transient frequency regulating rate, % |
5 |
|||||||||
Stabilizing time, voltage , S |
+1 |
|||||||||
Stabilizing time, frequency , S |
+12, -10 |
|||||||||
voltage regulating method |
automatic and manual |
|||||||||
Frequency regulating method |
manual |
|||||||||
starting method |
compressed air |
|||||||||
Lubricating method |
pressure lubricating |
|||||||||
Cooking method |
water cooling |
|||||||||
coupling |
flexible |
|||||||||
Overdimension, mm |
8950*2570*6050 |
|||||||||
Weight, Kg |
45000 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
Company Details
Business Type:
Manufacturer,Importer,Exporter,Seller
Year Established:
1995
Total Annual:
18,000,000-18,500,000
Employee Number:
175~450
Ecer Certification:
Site Member
KANGWEI ENVIRONMENT ENERGY UNITED GROUP KWEE has engaged in design and production for more than 20 years, With the many years accumulated mature development, the business range had included the large power diesel engine generator set and relevant auxiliary fuel oil system equi... KANGWEI ENVIRONMENT ENERGY UNITED GROUP KWEE has engaged in design and production for more than 20 years, With the many years accumulated mature development, the business range had included the large power diesel engine generator set and relevant auxiliary fuel oil system equi...
Get in touch with us
Leave a Message, we will call you back quickly!