Packaging Details | CONTAINER ,WOODEN CASE |
Delivery Time | Negotiate |
Payment Terms | T/T, L/C |
Supply Ability | 20SETS |
Fuel | diesel oil ,heavy fuel oil,gas |
speed | 550-750rpm |
designing capacity | 1-20MW |
power plant experience | 6 months engineering for 10MW power plant except in Africa |
output voltage | depend on the enduser |
fuel consumption | 201g/kwh |
contral system | SCADA DCS |
Place of Origin | QINGDAO , CHINA |
Brand Name | KANGWEI |
Certification | CCS,BV, IEC |
Model Number | According to the design and technical demand |
View Detail Information
Explore similar products
Water and air Cooling HFO heavy fuel oil Natural gas Fired Power Plant , Diesel
Customized HFO fired generator Power Plant Water Cooled Diesel Generator 0.4KV -
6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication
High Efficiency HFO Fired Power Plant Open Type 3 Phase Generator Set
Product Specification
Packaging Details | CONTAINER ,WOODEN CASE | Delivery Time | Negotiate |
Payment Terms | T/T, L/C | Supply Ability | 20SETS |
Fuel | diesel oil ,heavy fuel oil,gas | speed | 550-750rpm |
designing capacity | 1-20MW | power plant experience | 6 months engineering for 10MW power plant except in Africa |
output voltage | depend on the enduser | fuel consumption | 201g/kwh |
contral system | SCADA DCS | Place of Origin | QINGDAO , CHINA |
Brand Name | KANGWEI | Certification | CCS,BV, IEC |
Model Number | According to the design and technical demand | ||
High Light | heavy fuel oil power plant ,hfo based power plant |
10 X 2000kW Heavy Fuel Oil Power Plant 500 Rpm 600 Rpm With Generating Sets
Applications:
cement, textile, mining or oil and gas industries etc.
Competitive Advantage:
Our experts in application engineering and project management are the key to achieving very short construction times , builds turn-key power plant with an output up to 60MW as base load power plant, peaking power plant or industrial self-captive power plant in cement, textile, mining or oil and gas industries etc.
The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO)
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification |
||||||||||
Model |
2400GF |
2500GF |
||||||||
Rated power, KW |
2400 |
2500 |
||||||||
Overload , KW |
2640 |
2750 |
||||||||
Rated voltage, V |
400 |
415 |
3300 |
6300 |
10500 |
400 |
415 |
3300 |
6300 |
10500 |
Rated current , A |
4330 |
4174 |
525 |
275 |
165 |
4511 |
4348 |
547 |
172 |
286 |
Frequency , Hz |
50 |
50 |
||||||||
Power factor |
0.8 Lagging |
0.8 Lagging |
||||||||
Phase |
3 |
3 |
||||||||
Diesel engine |
GN832000ZD |
GN8320ZD |
||||||||
Rated power, KW |
2648 |
2795 |
||||||||
Rated rev, rpm |
750 |
750 |
||||||||
Alternator |
3 phase alternator |
|||||||||
voltage fluctuation rate% |
±1.0 |
|||||||||
Frequency fluctuation rate, % |
+12, -10 |
|||||||||
Stable voltage regulating rate, % |
3 |
|||||||||
Transient voltage regulating rate, % |
+12, -10 |
|||||||||
Stable Frequency fluctuation rate, % |
4
|
|||||||||
Transient frequency regulating rate, % |
5 |
|||||||||
Stabilizing time, voltage , S |
+1 |
|||||||||
Stabilizing time, frequency , S |
+12, -10 |
|||||||||
voltage regulating method |
automatic and manual |
|||||||||
Frequency regulating method |
manual |
|||||||||
starting method |
compressed air |
|||||||||
Lubricating method |
pressure lubricating |
|||||||||
Cooking method |
water cooling |
|||||||||
coupling |
flexible |
|||||||||
Overdimension, mm |
8950*2570*6050 |
|||||||||
Weight, Kg |
45000 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
Company Details
Business Type:
Manufacturer,Importer,Exporter,Seller
Year Established:
1995
Total Annual:
18,000,000-18,500,000
Employee Number:
175~450
Ecer Certification:
Site Member
KANGWEI ENVIRONMENT ENERGY UNITED GROUP KWEE has engaged in design and production for more than 20 years, With the many years accumulated mature development, the business range had included the large power diesel engine generator set and relevant auxiliary fuel oil system equi... KANGWEI ENVIRONMENT ENERGY UNITED GROUP KWEE has engaged in design and production for more than 20 years, With the many years accumulated mature development, the business range had included the large power diesel engine generator set and relevant auxiliary fuel oil system equi...
Get in touch with us
Leave a Message, we will call you back quickly!