China factories

China factory - Chengdu Shuwei Communication Technology Co., Ltd.

Chengdu Shuwei Communication Technology Co., Ltd.

  • China,Chengdu ,Sichuan
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Network Switch Bypass Switch Ethernet TAP Detect Heartbeat Packet Respond With
China Network Switch Bypass Switch Ethernet TAP Detect Heartbeat Packet Respond With

  1. China Network Switch Bypass Switch Ethernet TAP Detect Heartbeat Packet Respond With

Network Switch Bypass Switch Ethernet TAP Detect Heartbeat Packet Respond With

  1. MOQ: 1 SET
  2. Price: Can Discuss
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100 sets per month
Delivery Time 1-3 Working Days
Packaging Details Outer Carton plus Inner Foam
BYPASS links 8*10/100/1000M GE ethernet port
BYPASS Detection Intelligent Heartbeat Technology
Line speed 8Gbps
Reliable Data Access up/down link heartbeat package respond
Applications: Data Center Physical Connection Protection
Bypass switch Anti-DDOS attack protection
Brand Name NetTAP®
Model Number NT-CBYP-L2G
Place of Origin China
Certification CCC, CE, RoHS

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100 sets per month
Delivery Time 1-3 Working Days Packaging Details Outer Carton plus Inner Foam
BYPASS links 8*10/100/1000M GE ethernet port BYPASS Detection Intelligent Heartbeat Technology
Line speed 8Gbps Reliable Data Access up/down link heartbeat package respond
Applications: Data Center Physical Connection Protection Bypass switch Anti-DDOS attack protection
Brand Name NetTAP® Model Number NT-CBYP-L2G
Place of Origin China Certification CCC, CE, RoHS
High Light network bypass switchdynamic network tapbalancing network tap

Inline Bypass Ethernet TAP Detect Heartbeat Packet Respond with Dynamic Load Balancing
 
1. Bypass Switch Bypass TAP Intelligent Heartbeat Message Detection Technology
Multi-link Load Balancing Intelligent Network Traffic Allocation
The NetTAP® Traffic Traction Protector has intelligent traffic load balancing capability. When the performance of a single monitoring device is not sufficient to cope with the peak traffic of the serial link, the port load balancing group can be configured to connect the link traffic Assigned to the N monitor group, the protection device will be based on VLAN tag, MAC information, IP information, port number, protocol and other information on the Hash load balancing output, so the serial link traffic distribution to multiple security devices for cluster processing. It effectively improves the overall throughput of the safety equipment to meet the high bandwidth requirements of the deployment environment.
 
Dynamic Load Balancing
NetTAP® Policy Traction Protector provides a powerful dynamic load balancing function. When multiple monitoring devices load balanced network link traffic, the link load can be assigned to the N monitor groups by configuring the port load balancing group when the group member in the port load balancing group fails, the port load balancing group is automatically removed. When the member fails to recover, the port load balancing group is automatically added and the traffic load balancing output of the serial link is not required.
 
 
2. Intelligent Bypass Swtich Application Solution​
Based on the dynamic strategy of traffic traction security detection protection
"Bypass Switch" Another advanced application scenario is based on the dynamic strategy of traffic traction security detection protection applications, the deployment of the way as shown below:
 
Take the "anti-DDoS attack protection and detection" security testing equipment, for example, through the front-end deployment of "bypass switch" and then anti-DDOS protection equipment and then connected to the "bypass switch", in the usual " Traction protector "to the full amount of traffic wire-speed forwarding at the same time the flow mirror output to the" anti-DDOS attack protection device ", once detected for a server IP (or IP network segment) after the attack," anti-DDOS attack protection device " will generate the target traffic flow matching rules and send them to the "bypass switch" through the dynamic policy delivery interface. The "bypass switch" can update the "traffic traction dynamic" after receiving the dynamic policy rules Rule pool "and immediately" rule hit the attack server traffic "traction to the" anti-DDoS attack protection and detection "equipment for processing, to be effective after the attack flow and then re-injected into the network.
The application scheme based on the "bypass switch" is easier to implement than the traditional BGP route injection or other traffic traction scheme, and the environment is less dependent on the network and the reliability is higher.
"Bypass Switch" has the following characteristics to support dynamic policy security detection protection:
1,"bypass switch" to provide outside the rules based on WEBSERIVCE interface, easy integration with third-party security devices.
2,"bypass switch" based on the hardware pure ASIC chip forwarding up to 10Gbps wire-speed packets without blocking switch forwarding, and "traffic traction dynamic rule library" regardless of the number.
 
3,"policy flow traction protector" built-in professional BYPASS function, even if the protector itself failure, can also bypass the original serial link immediately, does not affect the original link of normal communication.
 
3. Bypass Switch Bypass TAP Technical Specifications

Product model Specifications
NT-FBYP-L1X-SR 1U chassis, 1*10GE multimode optical protection link
NT-FBYP-L1X-LR 1U chassis, 1*10GE single-mode optical protection link
NT-FBYP-L1G-SX 1U chassis, 1*GE multi-mode optical protection link
NT-FBYP-L1G-LX 1U chassis, 1*GE single mode optical protection link
NT-CBYP-L1G 1U chassis, 1*GE electrical protection link
NT-CBYP-L2G 1U chassis, 2*GE electrical protection link
NT-FBYP-L2G-SX5 1U chassis, 2*GE multi-mode optical protection link
NT-FBYP-L2G-LX 1U chassis, 2*GE single-mode optical protection link
NT-FCBYP-L4XG-SR 1U chassis, 2*GE electrical protection link, 1*GE multi-mode optical protection link, 1*10GE multimode optical protection link
NT-FCBYP-L4XG-LR 1U chassis, 2*GE electrical protection link, 1*GE single mode optical protection link, 1*10GE single mode optical protection link
 

2*GE Electrical BYPASS Links(NT-CBYP-L2G)

 

Product Model NT-CBYP-L2G
Interface form GE electrical port 8*10/100/1000M GE electrical port
SFP slot -
SFP+ slot -
GE electrical BYPASS link 2 links

 
Deploy mode

Number of Series protection links Maximum support for 2*GE electrical BYPASS links
Monitor Maximum support 2*GE links monitoring
Functional performance Total number of interfaces 8
Line speed processing capacity 8Gbps
Cross - link protection based on IP / protocol / port quintuple specific traffic Total number of interfaces
Based on the total flow of the series protection Support Support
Multi - channel load balancing function Support
Custom heartbeat message function Support
Ethernet encapsulation support Support
BYPASS switching function Support
Bypass switch without flash Support
CONSOLE network management Support
IP/WEB network management Support
SNMP V1/V2C network management Support
TELNET/SSH network management Support
SYSLOG protocol Support
User authentication function Based on user name and password authentication
Electric Rated supply voltage AC-220V/DC-48V【Optional】
Rated power frequency 50HZ
Rated input current AC-3A / DC-10A
Rated Power 40W
Environment Working Temperature 0-50℃
Storage temperature -20-70℃
Working humidity 10%-95%, No condensation
User configuration console configuration RS232 interface,9600,8,N,1
Outside network management interface 1*10/100/1000M Ethernet interface
Password authentication Support
Dimension Chassis dimension (U) 1U 485mm*44.5mm*350mm
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2007

  • Total Annual:

    8000000-10000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

NetTAP® (Full named Chengdu Shuwei Communication Technology Co., Ltd.)was established in 2007. Focusing on the Research and Development of Network TAPs/NPBs Communication Equipment, Data Security Analysis Equipment, which provides products and solutions in Big Data Acquisition, Data Storage, Dat... NetTAP® (Full named Chengdu Shuwei Communication Technology Co., Ltd.)was established in 2007. Focusing on the Research and Development of Network TAPs/NPBs Communication Equipment, Data Security Analysis Equipment, which provides products and solutions in Big Data Acquisition, Data Storage, Dat...

+ Read More

Get in touch with us

  • Reach Us
  • Chengdu Shuwei Communication Technology Co., Ltd.
  • 2F, G4 of TianFu Software Park, Chengdu, China.
  • https://www.network-packet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement