China factories

China factory - HUATEC  GROUP  CORPORATION

HUATEC GROUP CORPORATION

  • China,Beijing ,Beijing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China HG-5031L- Low Frequency Vibration Calibration System
China HG-5031L- Low Frequency Vibration Calibration System

  1. China HG-5031L- Low Frequency Vibration Calibration System

HG-5031L- Low Frequency Vibration Calibration System

  1. MOQ:
  2. Price:
  3. Get Latest Price
Frequency range 0.01 ~ 100 Hz (extensible)
Stroke 400 mm (optional 100 mm ~ 2m)
Max acceleration 20 m/s2 (extensible)
distortion degree < 5%
Brand Name HUATEC
Model Number HG-5031L
Certification ISO, CE, GOST
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Frequency range 0.01 ~ 100 Hz (extensible) Stroke 400 mm (optional 100 mm ~ 2m)
Max acceleration 20 m/s2 (extensible) distortion degree < 5%
Brand Name HUATEC Model Number HG-5031L
Certification ISO, CE, GOST Place of Origin China
High Light Low frequency vibration calibration systemVibration Calibration System Low frequency

HG-5031L- Low frequency vibration calibration system

 

The low frequency vibration calibration system uses unique photoelectric coding technology to control and generate low frequency vibration signals, which can complete the comparison method calibration of low frequency sensors with high precision and high efficiency. The laser interferometer can also be used for absolute calibration of low frequency sensors. The low frequency vibration calibration system can also generate dynamic deflection signals, and the laser interference deflection measurement interface can be extended to realize dynamic deflection calibration.

 

Specific technical index

Low frequency vibration calibration device (shaking table part)
Rated sinusoidal excitation force 200N
Frequency range 0.01~100 Hz (expandable)
Frequency indication error The error of the indicating value shall not be greater than 0.25% of the full scale
Signal-to-noise ratio Vibration table acceleration signal to noise ratio should be greater than 60dB
Work trip (Deflection measurement range) 400 mm(Expandable range 100 mm~2m)
Displacement range 1 μm ~ 400 mm(Scalable up to 2m)
Rated speed 1.2 m/s
Maximum acceleration @1Hz Not less than 0.5g
Acceleration range (10-4~20)m/s2
Maximum load sensor mass >10kg
Table size >240mm×240mm
Equivalent mass of moving parts 8 kg
Table screw M5(It can be customized according to requirements)
Overall dimensionL×W×H About 1200mm×300mm×300mm
Platform weight About 90 kg
Gas supply pressure 0.4~0.6MPa
Maximum gas flow 10L/min
Waveform distortion In the working frequency response range, the distortion of the center acceleration waveform of the mesa is not more than 5%
Lateral vibration ratio In the working frequency response range, the transverse vibration acceleration amplitude of the center of the mesa is not greater than 5% of the vibration acceleration amplitude of the main vibration direction.
stability The vibration table continuously vibrates at the reference frequency point of 16Hz with the maximum acceleration amplitude for 20min. Within any 2min interval, the maximum change in frequency is not more than 0.3%, and the maximum change in acceleration amplitude is not more than 0.5%.
Standard acceleration sensor
sensitivity Not less than 1000mV/g
Frequency response range DC-200Hz (±5%)
Measuring range 2 g
Resolution Less than 10 μg
nonlinearity 0.1%FS
Photoelectric encoder can also be used below 10Hz, resolution Not greater than 10nm
Vibration control system and control calibration software
channels ≥4 channels, each channel using independent A/D
digit 24bit
Sampling rate Each channel is greater than 20k
Laser interferometer interface Expandable laser interferometer interface with deflection function
All hardware is driven by software, and the test of all parameters of the complete system is controlled by the program.
It can perform step sine and sweep sine, amplitude frequency calibration, phase frequency calibration and amplitude linearity calibration of the measured sensor
The amplitude linearity, amplitude frequency error and phase error of the sensor can be calculated
User-defined test report, all test parameters and calculation results can be displayed in the report
System working environment requirements
Operating ambient temperature 5℃~+35℃
Relative humidity 10% to 85%
Power supply 220V±10V AC,50Hz±1 Hz,3.5kW
Compressed air requirement Not higher than 0.6Mpa
Laboratory grounding resistance(Ω) ≤4
     
 

 

Low frequency vibration calibration system

No Part name Main technical index Qty
1

Low frequency standard shaker and low frequency controller

IM-LF01

Meet JJG 298-2005 intermediate frequency standard vibration table (comparative method) verification regulations

1. Frequency range: 0.1Hz ~ 100Hz;

2. Acceleration range: ≥20 m/s2;

3, standard vibration table maximum load: ≥10Kg;

4. Distortion degree: ≤5%;

5. Lateral movement ratio: ≤10%;

6. Acceleration stability: 0.1%, frequency stability: 0.1%.

1
2

Standard acceleration sensor

MSV-3001

1. Sensitivity: ≥1000mV/g;

2. Frequency range: 0.1Hz~200Hz

1
3

Vibration control system (including software)

NIM-DA01

1. Number of acquisition channels: ≥2;

2, AD bits: 24 bit;

3, sampling rate: ≥50 kHz;

4, voltage measurement range: ±5V.

5, voltage measurement error: better than 0.2%;

6, voltage ratio measurement error: better than 0.1%;

7, including automatic and manual calibration two modes;

8, can automatically generate reports.

1
4

Conditioning amplifier

YMC-8102

1 charge /IEPE/TEDS channel, support charge sensor signal amplification and conditioning, IEPE sensor constant current source power supply and signal conditioning, TEDS sensor signal conditioning; Support channel integration, RS-232 interface and PC communication, multiple can be cascaded, CE certification; 1 set
5 Air compressor system Supply of compressed air 1 set
6 Computer i7 processor, 8g memory, 1T hard disk, including multiple USB ports and PCI slots, two network ports, including optical drive 1 set
7 meterage First measurement charge 1
 

 

Characteristic

 Unique low frequency vibration generator for plane motion

 Precise and efficient zero control function

 Large work schedule

 drifts regardless of gravity

 Deflection calibration is also possible

 multi-channel 24-bit high-precision dynamic signal analysis system

 Multiple sensors can be calibrated simultaneously

 uses unique digital control technology

 

Main technical index

 Frequency range: 0.01 ~ 100 Hz (extensible)

 Stroke: 400 mm (optional 100 mm ~ 2m)

 Max acceleration: 20 m/s2 (extensible)

 distortion degree: < 5%

 lateral motion ratio: < 10%

 Load: > 10 kg

 Measurement uncertainty: 2% (k=2)

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2007

  • Total Annual:

    500000-1000000

  • Employee Number:

    35~50

  • Ecer Certification:

    Verified Supplier

HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified... HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified...

+ Read More

Get in touch with us

  • Reach Us
  • HUATEC GROUP CORPORATION
  • 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
  • https://www.ndttester.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement