Model NO. | tail gas treatment plant generator |
Standard | Standard |
Modle | 6190, 12V190, 16V190 |
Rated Power | 200kw-1000kw |
Speed | 1000/1200 |
Frequency | 50Hz/60Hz |
Transport Package | Wood Case |
Trademark | Jinan Simeno |
Origin | Jinan, China |
HS Code | 8411810090 |
Supply Ability | 3200 Pieces/Year |
After-sales Service | Permanent Online Service |
Warranty | 1 Year |
Output Type | AC Three Phase |
Gas Source | Co, CO2, N2, H2 |
Power | 200-1000kw |
Customization | Available | Customized Request |
Packaging Details | Wooden box and carton packaging |
Delivery Time | 15 days |
Payment Terms | TT,western |
Certification | ISO9001 |
Place of Origin | china |
View Detail Information
Explore similar products
AC Three Phase Diesel Generator Z12V190b Jichai Chidong 800kw Distrobutor Energy
Customization 12V190 Cylinder Block Assembly for Jichai/Chidong Gas Generator
DC Output Type 1000kw Coal Gas Generator for Standard Coal Mine Operation
DC Output Type 1000kw Coal Mine Gas Generator for Customized Request and
Product Specification
Model NO. | tail gas treatment plant generator | Standard | Standard |
Modle | 6190, 12V190, 16V190 | Rated Power | 200kw-1000kw |
Speed | 1000/1200 | Frequency | 50Hz/60Hz |
Transport Package | Wood Case | Trademark | Jinan Simeno |
Origin | Jinan, China | HS Code | 8411810090 |
Supply Ability | 3200 Pieces/Year | After-sales Service | Permanent Online Service |
Warranty | 1 Year | Output Type | AC Three Phase |
Gas Source | Co, CO2, N2, H2 | Power | 200-1000kw |
Customization | Available | Customized Request | Packaging Details | Wooden box and carton packaging |
Delivery Time | 15 days | Payment Terms | TT,western |
Certification | ISO9001 | Place of Origin | china |
Gas composition and calorific value parameter table | |||||
Gas species | Composition (volume %) | Calorific value MJ/Nm3 | |||
Industrial tail gas | CO | H2 | CO2 | N2 | 11 |
84 | 5 | 5 | 6 |
The industrial exhaust generator set is mainly developed for the gas with high carbon monoxide content. It is developed by new optimization and design on the foundation machine. The unit as a whole adopts modular design, distributing three modules of motor, engine and supercharging and cooling. The engine is placed in the middle, which is convenient for daily maintenance. Inlet and exhaust, and cooling water are concentrated at the free end, which is convenient for installation and layout of the power station.
engine adopts the shunt inlet double pressurization technology, which is specially developed for hydrogen-containing units. The structure is reliable and the operation is safe. The twin supercharger has been optimized and matched to provide efficient pressurization pressure for the engine and improve the operation power and efficiency of the unit.
Modle | 6190 | 12V190 | 16V190 | |||
CP200GFJ13 | CP250GFJ13 | CP500GFJ11 | CP600GFJ11 | CP700GFJ11 | CP1000GFJ12 | |
Electric power kill, kW | 200 | 300 | 500 | 600 | 700 | 1000 |
Waste heat, kW | 253 | 366 | 597 | 713 | 828 | 1100 |
Electrical efficiency, % | 34 | 36 | 36 | 37 | 38 | 40 |
Thermal efficiency, % | 43 | 44 | 43 | 44 | 45 | 44 |
Total efficiency, % | 77 | 80 | 79 | 81 | 83 | 84 |
The product has the characteristics of high efficiency, low energy consumption and low emission. Unit core control system parts, including ECU, air-fuel ratio control system, speed control system, ignition system and other parts are all independent, reliable product quality, has been widely used in gas units. The unit adopts SE3 control system, which has good man-machine interaction and maneuverability. CR gas unit integrates the advantages of high-performance engine, core control parts and advanced gas unit control system, which has been recognized by customers in the market.
1. High Power |
The maximum power of the unit is 700kW under the condition that the air source and operating environment meet the requirements. |
2. Highly Efficient |
The twin supercharger matching technology has been optimized and verified for a long time, with reliable structure and high operation efficiency, which enables the unit to run at full load for a long time. |
3. Reliability is Good |
All the main components are optimized. The control system has comprehensive functions, complete parameter collection and many protection items. |
4. Good adaptability and Good adaptability |
The unit is specially optimized, and can adapt to the change of gas source on site. |
5. Easy operation and maintenance |
Unit three modular design, easy maintenance. High degree of automation of control system. Simple to operate. |
Modle | 6190 | 12V190 | 16V190 | |||
CP200GFJ13 | CP250GFJ13 | CP500GFJ11 | CP600GFJ11 | CP700GFJ11 | CP1000GFJ12 | |
Cylinder diameter/stroke,mm | 190/210 | 190/210 | 190/210 | 190/210 | 190/210 | 190/210 |
Number of cylinders | 6 | 6 | 12 | 12 | 12 | 16 |
Displacement | 35.7 | 35.7 | 71.4 | 71.4 | 71.4 | 95.2 |
Speed, r/min | 1,000/1,200 | |||||
Frequency, Hz | 50/60 | |||||
Long, mm | 4500 | 4500 | 6200 | 6200 | 6300 | 7000 |
Wide, mm | 1300 | 1300 | 1950 | 1950 | 1950 | 1900 |
High, mm | 2365 | 2365 | 2175 | 2175 | 2175 | 2600 |
Weight, kg | 7000 | 8400 | 11500 | 12000 | 12650 | 24000 |
1. Three-stage modular design |
The unit adopts three-stage modular design, gas engine, turbocharged intercooling and generator three-stage design, to improve the maintenance operation of the unit; |
The engine is in the middle of the unit, with less auxiliary equipment on both sides, which is convenient for daily maintenance. The air intake and exhaust are concentrated at the free end, which is convenient for the layout of the power station. The three modules are evenly distributed to make the unit more evenly distributed and easier to lift. |
2. Shunt air intake technology |
For the biomass gas containing hydrogen, methane value is low, the combustion speed is fast, the gas machine is easy to temper and detonation, the use of the branch inlet technology, reliable structure, compared with the multi-point electronic injection, mechanical injection, the control mechanism is simple and reliable; , completely avoid tempering |
3. Shunt pressurization technology |
Adopting the shunt pressurization technology, the unit has high operation safety, the gas does not need other auxiliary pressurization equipment, saves energy consumption, and realizes the low pressure gas inlet. |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2010
Total Annual:
3000000-4000000
Employee Number:
100~110
Ecer Certification:
Verified Supplier
Jinan Guohua Green Power Equipment Co, Ltd, established in 2010, is a professional high-tech enterprises specialized in power station integration and parts sales, assemble. We invest in chidong 190 diesel engines, gas engines and shengdong 190 diesel engine. With a wealth of professional project eng... Jinan Guohua Green Power Equipment Co, Ltd, established in 2010, is a professional high-tech enterprises specialized in power station integration and parts sales, assemble. We invest in chidong 190 diesel engines, gas engines and shengdong 190 diesel engine. With a wealth of professional project eng...
Get in touch with us
Leave a Message, we will call you back quickly!