China factories

China factory - Knkong Electric Co.,Ltd

Knkong Electric Co.,Ltd

  • China,Zhengzhou ,Henan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China KNKONG JP-400 LV Meter Distribution Box IEC439-1
China KNKONG JP-400 LV Meter Distribution Box IEC439-1

  1. China KNKONG JP-400 LV Meter Distribution Box IEC439-1

KNKONG JP-400 LV Meter Distribution Box IEC439-1

  1. MOQ: 1
  2. Price: USD 2000-10000
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 100 Unit per month
Delivery Time 15 days
Packaging Details Standard export packaging
Voltage 400V
Frequency 50Hz
Capacity 30/50/63 80/100/125/160/200/250/315/400/500/630
Manufactory KNKONG
Standards ISO IEC GB
OEM/ODM Inquiry by email
Brand Name Knkong
Model Number JP400
Certification ISO IEC CB
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 100 Unit per month
Delivery Time 15 days Packaging Details Standard export packaging
Voltage 400V Frequency 50Hz
Capacity 30/50/63 80/100/125/160/200/250/315/400/500/630 Manufactory KNKONG
Standards ISO IEC GB OEM/ODM Inquiry by email
Brand Name Knkong Model Number JP400
Certification ISO IEC CB Place of Origin China
High Light JP-400 LV Meter Distribution BoxIEC439-1 Meter Distribution BoxLV meter distribution board

KNKONG JP-400 LV Meter Distribution Box IEC439-1

 

Product Introduction

JP low-voltage integrated distribution box shall comply with IEC439-1 "Low-voltage switchgear and control equipment", GB7251.12-2013 "Low-voltage switchgear and control equipment Part 2: Complete power switch and control equipment", GB/T15576- 2008 "Low-Voltage Complete Reactive Power Compensation Device" related standard requirements.

 

Service environment
1. Air temperature: -25℃---+40℃
2. Humidity: Monthly average humidity 95%; Daily average humidity 90%.
3. Altitude: ≤ 2500m
4. Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
5. No frequent violent shake

 

Installation requirements
1. The switchboard (box) should be made of non-combustible materials;
2. In production sites and offices with low risk of electric shock, open-type power distribution boards can be installed;
3. Closed cabinets should be installed in processing workshops, casting, forging, heat treatment, boiler rooms, wood workshops and other places where the risk of electric shock is high or the working environment is poor;
4. Airtight or explosion-proof electrical facilities must be installed in hazardous workplaces with conductive dust or flammable and explosive gases;
5. The electrical components, meters, switches and circuits of the distribution board (box) should be neatly arranged, firmly installed and easy to operate. The bottom surface of the floor-mounted board (box) should be 5~10 mm above the ground;
6. The center height of the operating handle is generally 1.2~1.5m; there is no obstacle within the range of 0.8~1.2m in front of the board (box);
7. The connection of the protection wire is reliable; no bare live body shall be exposed outside the board (box);
8. The electrical components that must be installed on the outer surface of the board (box) or on the distribution board must have reliable shielding

 

Main Parameter

NO. Description Unit Parameter
1 Rated voltage V 400
2 Rated frequency HZ 50
3 Capacity KVA 30 50 63 80 100 125 160 200 250 315 400 500 630
4 Capacitor grouping   2 3 4 5 levels (according to user requirements )
5 Bus bar Rating A 630
6 The metal used for busbars   Copper
7 Type of protection used on busbars against corrosion (e.g. heavily tinned)   Tinned Plating
8

Dimens ions of busbars

(length x width x thickness)

mm 660 x 50x 5
9 Method of connection between busbars and cable lugs (cable lugs not to be provided)  

Bolted Typ e

 

10 Fixing center of HRC fuse mm 90
11 Ar e-safety barriers fitted between phases of the same incoming or outgoing unit?   Yes
12 Are insulating shields fitted between adjacent units?   No
13 Minimum clearance between the lowes t cable connection and ground level mm 300
14 Material used for housing  

Ho t Dipped

Galvanized Sheet

15 Treatment of housing against atmospheric corrosion   7 Tank Process
16 Padlocking facility on housing door  

Yes

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2012

  • Total Annual:

    1000000-9000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import.   Relying on a h... Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import.   Relying on a h...

+ Read More

Get in touch with us

  • Reach Us
  • Knkong Electric Co.,Ltd
  • No. 25 Street , Hanghai Road, Zhengzhou,Henan,China
  • https://www.mvlvswitchgear.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!