China Withdrawable Solid Sealed Pole VCB Circuit Breaker 20KA Breaking
China Withdrawable Solid Sealed Pole VCB Circuit Breaker 20KA Breaking

  1. China Withdrawable Solid Sealed Pole VCB Circuit Breaker 20KA Breaking

Withdrawable Solid Sealed Pole VCB Circuit Breaker 20KA Breaking

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 1000 Unit per month
Delivery Time 15 working days
Packaging Details Standard export packaging
Using Voltage 12-24KV
Running Current 630A 1250A 2000A
Breaking capacity max 20KA
Type withdrawable
Original China
Manufactory KNKONG-ELECTRIC
Brand Name KNKONG
Model Number VS1-12
Certification CB,ISO,IEC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 1000 Unit per month
Delivery Time 15 working days Packaging Details Standard export packaging
Using Voltage 12-24KV Running Current 630A 1250A 2000A
Breaking capacity max 20KA Type withdrawable
Original China Manufactory KNKONG-ELECTRIC
Brand Name KNKONG Model Number VS1-12
Certification CB,ISO,IEC Place of Origin China
High Light Withdrawable Modular VCB Circuit Breaker20KA Breaking VCB Circuit BreakerISO VCB Circuit Breaker

20KA Breaking alternating withdrawable solid-sealed pole VCB 12KV VS1 series

Voltage: 12-24 KV

Current: 630-1250A-2000A

Breaking current: max 20KA

Type: withdrawable

 

 

Product overview

 

Secondary circuit

The secondary control circuit board of Knkong-electric's VS1 series vacuum circuit breaker uses a modular design. The electrical connection of the machine uses high-grade self-buckle plugs, which are convenient for replacement and ensures reliable operation of the electrical connection.

 

High-performance oil buffer

The high-performance breaking buffer can significantly reduce the amplitude of overshoot and spring back generated by the moving contact of the VS1 vacuum circuit breaker during breaking, and avoid the overshoot of the moving contact leading to partial fatigue of the vacuum interrupter bellows Loss of mechanical durability. With the decrease of the rebound amplitude of the moving contact, the reignition phenomenon has not been found in the test of the switched capacitor bank.

 

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

 

Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

 

 

4

 

 

Rated current

 

 

A

630 630 1250 1600
1250 1250 1600 2000
    2000 2500
    2500 3150
      4000
5 Rated short-circuit breaking current

 

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit     s 4
10 Rated operating sequence   O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

 

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

 

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

 

≤100
24 Breaking time ≤50

 

 

25

 

Resistance of each phase main circuit

 

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

 

27

Rated operating voltage Rated operating voltage(V)AC/DC

 

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220,DC110/220
29 Energy storage time S ≤15

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2012

  • Total Annual:

    1000000-9000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import.   Relying on a h... Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import.   Relying on a h...

+ Read More

Get in touch with us

  • Reach Us
  • Knkong Electric Co.,Ltd
  • No. 25 Street , Hanghai Road, Zhengzhou,Henan,China
  • https://www.mvlvswitchgear.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement