Payment Terms | L/C, D/P, D/A, T/T |
Packaging Details | paper carton |
Product name | Portable Gas Analyzer |
Gas unit | PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l. |
Color | Black |
Protection level | IP66 |
Weight | 350g |
Size | 180*78*33mm |
Warranty | 12 Months |
Brand Name | Zetron |
Model Number | MS500 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
MS500 5 In 1 Gas Detector , Portable Toxic And Combustible Gas Leak Detector
Portable Ammonia Gas Detector NO2 HCN CLO2 O3 Audible Visual Vibrating Alarms
5 In 1 Portable Toxic Gas Detector Combustible Cooling Filter MS500
Black Handheld Multi Gas Detector , Five In One Gas Flow Detector MS500 IP66
Product Specification
Payment Terms | L/C, D/P, D/A, T/T | Packaging Details | paper carton |
Product name | Portable Gas Analyzer | Gas unit | PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l. |
Color | Black | Protection level | IP66 |
Weight | 350g | Size | 180*78*33mm |
Warranty | 12 Months | Brand Name | Zetron |
Model Number | MS500 | Certification | CE |
Place of Origin | China | ||
High Light | ip66 outdoor air quality monitor ,5in1 outdoor air quality monitor ,zetron portable lpg gas leak detector |
MS500- 5 in 1 Toxic and Harmful Portable Gas Detector
MS500 portable toxic and hazardous gas detector can detect gas concentrations in pipelines or confined spaces, atmospheric environments, gas leaks, or various background gases such as ammonia or oxygen with high concentrations of single gas purity, and more than 500 types of gases. It adopts a 2.5-inch HD color screen to display the concentration in real-time. The main detection principles are electrochemical, infrared, catalytic combustion, thermal conductivity, PID light ion.
· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose and the standard length is 1 meter)
· 0.4-meter stainless steel sampling handle (with a dust filter, not retractable)
· High-temperature sampling and cooling filter handle
· High-temperature humidity pretreatment system
· CD-ROM (upper-level computer communication software)
· External mini wireless infrared printer
Gases to be detected | Arbitrary combination of 1 ~ 5 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. | ||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. | ||||
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol | ||||
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. | ||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. | ||||
Allowable error | ≤±2% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. | ||||
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 800 ℃ or higher. | ||||
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH | ||||
Power supply | 3.6VDC, 5500mA high capacity rechargeable polymer battery | ||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, Turning off the alarm. | ||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | ||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries | ||||
Protection level | IP66 | ||||
Explosion-proof mark | Exia II CT6 | ||||
Exterior dimensions | 180×78×33mm (L×W×H) | ||||
Weight | 350g | ||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter |
All the cases require the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, smoke gas analysis, air governance, and so on.
Company Details
Business Type:
Distributor/Wholesaler,Agent,Seller
Year Established:
2001
Total Annual:
10000000-15000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Zetron Technology is a professional company committed to developing the gas detection industry. It has more than 18-year experience specializing in the research, development, manufacture, and sale of gas detectors. With its strong technical force and economic strength, the company i... Zetron Technology is a professional company committed to developing the gas detection industry. It has more than 18-year experience specializing in the research, development, manufacture, and sale of gas detectors. With its strong technical force and economic strength, the company i...
Get in touch with us
Leave a Message, we will call you back quickly!