Supply Ability | 10 million meters per year |
Delivery Time | in one month |
Packaging Details | plywood crates |
Dimensions | 0.2"x0.3" (5mm x 8mm) 12 AWG |
Dielectric Strength | Over 2000 volts |
Property | As per project application |
Usage | Thermal Power Plant |
Flame Resistance | Good |
Wattage | 39Watt/meter |
Max. Exposure Temp. (°F) Power Off | 260 or Customized |
Voltages | Up to 480 |
Brand Name | MICH |
Model Number | EHTTSTPCP |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
380V MI Trace Heating Cables Hot Water Maintenance
Roll On To Roll Off Wharf Area Edible Oil Electric Heat Tracing 25KW
6X Heat Tracing On Pipe Liquefied Natural Gas Storage Plant
Mineral Insulated Heating Cable In Mine And Minerals
Product Specification
Supply Ability | 10 million meters per year | Delivery Time | in one month |
Packaging Details | plywood crates | Dimensions | 0.2"x0.3" (5mm x 8mm) 12 AWG |
Dielectric Strength | Over 2000 volts | Property | As per project application |
Usage | Thermal Power Plant | Flame Resistance | Good |
Wattage | 39Watt/meter | Max. Exposure Temp. (°F) Power Off | 260 or Customized |
Voltages | Up to 480 | Brand Name | MICH |
Model Number | EHTTSTPCP | Certification | ISO9001 |
Place of Origin | China | ||
High Light | 2 Core Pipe Tracing Heating Tape Cables ,antifreeze Pipe Tracing Heating Tape Cables ,2 Core electric pipe heaters |
Electric Heat Tracing Technical Solution for Thermal Power Combined Plant is mainly designed for freeze protection for pipelines, tanks, instrumentations etc for the thermal power plant. The principle used to build Combined-cycle Thermal Power Stations consists in an arrangement of heat engines working together from the same source of heat, turning it into mechanical energy that drives electrical generation.
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Selection Parameters:
Constant Wattage Heating Cable | High Temperature Heating cable | Polyamide/Fiberglass Heating Cable | Harsh Environment Heating Cable | General Purpose Heating Cable |
Available Voltages | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC |
Available Wattages
| 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m) |
Maximum Exposure Temperature | 500°F (260°C)
| 500°F (260°C)
| 500°F (260°C)
| 400°F (204°C)
|
Nominal Dimensions
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG |
Resistance to Moisture | Good | Good | Excellent
| Excellent
|
Resistance to Chemicals | Good | Good | Excellent
| Excellent
|
Resistance to Flame | Excellent | Outstanding | Excellent | Outstanding |
Dielectric Strength | Over 2000 volts | Over 2000 volts
| Over 2000 volts | Over 2000 volts |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us
Leave a Message, we will call you back quickly!