China factories

China factory - Pasia Industries Ltd

Pasia Industries Ltd

  • China ,Zhejiang
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 600V Electric Heat Tracing
China 600V Electric Heat Tracing

  1. China 600V Electric Heat Tracing
  2. China 600V Electric Heat Tracing

600V Electric Heat Tracing

  1. MOQ: 1 meter
  2. Price: USD0.5-USD5 per meter
  3. Get Latest Price
Supply Ability 10 million meters per year
Delivery Time in one month
Packaging Details plywood crates
Conductor Copper or alloy
Sheath Metal
Insulation High Purity Magnesium Oxide
Usage Vessels and Tanks
Min. Bend Radius 6 X Cable Diameter
Max. Maintenance Temp. (°F) 900
Max. Exposure Temp. (°F) Power Off 1100
Property Highest Temperature and Cut-to-Length
Brand Name MICH
Model Number HTCTLHTMIHC
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 million meters per year Delivery Time in one month
Packaging Details plywood crates Conductor Copper or alloy
Sheath Metal Insulation High Purity Magnesium Oxide
Usage Vessels and Tanks Min. Bend Radius 6 X Cable Diameter
Max. Maintenance Temp. (°F) 900 Max. Exposure Temp. (°F) Power Off 1100
Property Highest Temperature and Cut-to-Length Brand Name MICH
Model Number HTCTLHTMIHC Certification ISO9001
Place of Origin China
High Light 600V Electric Heat Tracing200W/m Electric Heat Tracing600V electric heat cable

Highest Temperature Cut-to-Length Heat Trace Mineral Insulated Heating Cable is used on heat trace solutions for the extreme working conditions with the trace temperature higher up to 425ºC then there is only mineral insulated heating cable workable. The cable is with metal sheath so the real installed length should be pre-calculated and cut into length in workshop for proper installation at field.


Patented mineral insulated, metal sheathed, electric heating cable can withstand 425ºC continuously, and deliver up to 200W/m. It can cater for virtually all applications outside the capability of the self-regulating tracer range.

 

 

Cable Structure

 

 

Specification

Heating cable instruction code

 

 

MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

 

No. Instruction  
1 Sheath material CU
2 structure of cable components shown in table 1
3 cable codes shown in table 2, 3 and 4
4 length of heating cable In meter
5 Heating cable power In Watt
6 heating cable voltage In Volt
7 heating cable voltage See table 5

 

 

 

 

 

 

 

 

 

 

Cable Code

 

1 6 K 320

No. 1 2 3 4

 

Serial NO. Instruction  
1 core number 1 or 2
2 Voltage grade 3=300V, 6=600V
3 conductor materials C,K
4 cold resistance ×1000 320=0.32Ω/m×1000

 

 

 

 

 

 

 

Table 1 Structure of Cable Element

 

 

Note: Model C, F and G are suitable for being used at temperature under 65

 

Table 2 Heating Cable Specification (600V Single Conductor)

 

Cable Code Diameter HDPE Diameter Standard resistance value at +20 Maximum Production Length Unit weight
mm mm Ω/m m kg/km
16C1.7 8.2 10 0.0017 350 366.54
16C2.2 7.6 9.4 0.0022 380 307.77
16C2.9 7.0 8.8 0.0029 400 264.45
16C4 5.9 7.7 0.004 600 190.88
16C7 5.3 7.1 0.007 600 154.08
16C11 4.9 6.7 0.011 600 132.25
16C13 4.6 6.4 0.013 600 (300)☆ 125.7
16C17 4.6 6.4 0.017 600 (300)☆ 117.16
16C21 4.6 6.4 0.021 600 (300)☆ 111.9
16C25 3.7 5.5 0.025 600 (480)☆ 68.83
16C33 3.7 5.5 0.033 600 (480)☆ 63.76
16C40 3.4 5.2 0.04 600 (560)☆ 58.87
16C63 3.2 5 0.063 600 51.47
16K80 6.8 8.6 0.08 370 (140)☆ 254.18
16K100 5.2 7 0.1 450 (240)☆ 162.11
16K140 4.9 6.7 0.14 600 (270)☆ 122.55
16K197 4.45 6.25 0.197 600 (330)☆ 111.32
16K220 4.5 6.3 0.22 600 (330)☆ 102.89
16K315 4.3 6.1 0.315 600 (350)☆ 91.44
16K345 4.2 6.0 0.345 600 (370)☆ 85.9
16K450 4.0 5.8 0.45 600 (400)☆ 80.73
16K630 4.0 5.8 0.63 600 (400)☆ 77.26
16K800 3.5 5.3 0.8 600 (530)☆ 61.48
16K1250 2.8 4.6 1.25 600 40.83
16K2000 2.8 4.6 2.0 600 38.96

 

 

Table 3 Heating Cable Specification (600V Double Conductors)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26C3.4 12.9 0.0034 150 783.76
26C4.4 12.2 0.0044 160 701.56
26C5.8 11.3 0.0058 170 606.16
26C8.6 9.90 0.0086 180 451.43
26C11.4 9.30 0.0114 200 400.05
26C13.8 9.00 0.0138 210 375.20
26C17.2 8.60 0.0172 220 344.90
26C23 8.00 0.023 250 303.25
26C34.4 7.50 0.0344 280 269.20
26C49.2 7.10 0.0492 300 243.84
26K240 9.90 0.24 180 451.43
26K320 9.30 0.32 200 400.05
26K384 9.00 0.384 210 375.20
26K480 8.60 0.48 220 344.90
26K640 8.00 0.64 250 303.25
26K960 7.50 0.96 280 269.20

 

 

Table 4 Heating Cable Specification (300V Double Cores)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23C3.4 12.0 0.0034 200 708.10
23C4.4 11.3 0.0044 220 629.07
23C5.8 10.4 0.0058 240 537.73
23C8.6 9.00 0.0086 260 392.56
23C11.4 8.40 0.0114 280 343.89
23C13.8 8.00 0.0138 300 314.57
23C17.2 7.60 0.0172 320 286.27
23C23 7.10 0.023 340 252.98
23C34.4 6.60 0.0344 360 221.19
23C49.2 6.20 0.0492 380 197.64
23K160 10.4 0.16 220 508.37
23K240 9.00 0.24 240 392.56
23K320 8.40 0.32 265 343.89
23K384 8.00 0.384 280 314.57
23K480 7.70 0.48 300 291.91
23K640 7.10 0.64 320 252.98
23K960 6.50 0.96 350 216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH

 

 

Table 5 terminal specifications

 

  Model: A, D, E Model: B  
Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V)
       
600 15 E2 20 E1 15 E1
600 20 E2 25 E2 20 E1
600 30 E3 40 E2 30 E2
600 50 E3 70 E2 50 E2
600 70 E3 100 E3 70 E2

 

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

 

Corresponding reference table between the output power and sheath temperature

 

 

Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.

 

Anticorrosive specification

 

Material

MICU

MIHC
Sulfate Not recommend Excellent
Hydrochloric acid Not recommend Excellent
Hydrofluoric acid Acceptable Acceptable
Phosphate Acceptable Acceptable
Carbonate Not recommend Acceptable
Organic acid Acceptable Not recommend
Alkali metal Acceptable Acceptable
Sea water Not recommend Acceptable
Chloride Data checking required Acceptable

 

Explosion-proof instructions

 

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Employee Number:

    150~200

  • Ecer Certification:

    Active Member

Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...

+ Read More

Get in touch with us

  • Reach Us
  • Pasia Industries Ltd
  • 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
  • https://www.miheatingcables.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement