Payment Terms | L/C, T/T |
Supply Ability | 20 million meters |
Delivery Time | in one month |
Packaging Details | plywood crates |
Sheath | Stainless Steel |
Function | Heating or Heat Trace |
Application | Shipbuilding |
Diameter | up to project request |
Cable Length | in Meter |
Power | in Watt |
Property | High Strength |
Unit Weight | Up to 184 kg/km |
Brand Name | MICH |
Model Number | SSSMIHES |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
8.2MM Sheathed Heating Element for Chemical Industry Heating
Power Plant Mineral Insulated Heating Elements
Convenient Electrical Control MI Heating Element Of Heater
600V Double Cores High Temperature Heating Element
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 20 million meters |
Delivery Time | in one month | Packaging Details | plywood crates |
Sheath | Stainless Steel | Function | Heating or Heat Trace |
Application | Shipbuilding | Diameter | up to project request |
Cable Length | in Meter | Power | in Watt |
Property | High Strength | Unit Weight | Up to 184 kg/km |
Brand Name | MICH | Model Number | SSSMIHES |
Certification | ISO9001 | Place of Origin | China |
High Light | SS Mineral Insulated Heating Elements ,Mineral Insulated Heating Element Shipbuilding ,500v low voltage heating element |
Stainless Steel Sheathed Mineral Insulated Heating Element for Shipbuilding
Stainless Steel Sheathed Mineral Insulated Heating Element for Shipbuilding is a specially developed and designed heating element for commercial ship and warship building industries for the applications:
1. Heating and condensation prevention for ship deck and cabin;
2. Heating or tracing of water, steam pipelines and related devices.
Mineral Insulated Heating Element for Chemical Industry Heating or Heat Trace is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable.
Common structure of the heating cable for the heating element is of single core and two core, while the customization can be according to clients’ needs to design and provide MI heating cable of three core or more.
Specifications
Heating cable instruction code
NO. 1 2 3 4 5 6 7MI CN-B 16K239/60/2520/220/E1
NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | K,N,C |
4 | cold resistance ×1000 | 239=0.239Ω/m×1000 |
Cable Code
1 6 K 239
No. 1 2 3 4
No. | Instruction | |
1 | Sheath material | Cu-Ni |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Code description:
Serial number | Name | Code | Code name | Interpretation |
1 | Model | a | Product name | MI: Mineral insulated cold end cable |
b | Sheath material | HC: copper sheath + HDPE jacket HF: Copper sheath + flame retardant HDPE jacket SS: Stainless steel sheath AL: 825 alloy sheath | ||
2 | Specifications | c | Number of conductor cores | 1: Single core (1 core) 2: Double core (2 core |
d | Voltage level | L:500V H:750V | ||
e | Conductor section | Nominal section area of conductor (mm2) |
Note: the cold end cable of the model specifications of the bare copper sheathed mineral insulated can also be expressed in accordance with the method specified in GB/T 13033.1.
Table 2 Heating Cable Specification (600V Single Core)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
16C2.1 | 6.8 | 0.0021 | 130 | 220.7 |
16C3.4 | 5.9 | 0.0034 | 173 | 162.5 |
16C5.3 | 5.3 | 0.0053 | 214 | 125.6 |
16C8.5 | 4.8 | 0.0085 | 261 | 101.6 |
16C13 | 4.3 | 0.013 | 325 | 79.1 |
16C21 | 4.0 | 0.021 | 376 | 65.8 |
16K40 | 5.8 | 0.04 | 179 | 157.1 |
16K50 | 5.4 | 0.05 | 206 | 135.6 |
16K60 | 5.2 | 0.06 | 222 | 122.8 |
16K80 | 4.8 | 0.08 | 261 | 101.2 |
16K100 | 4.7 | 0.1 | 200 | 99.5 |
16K120 | 4.5 | 0.12 | 200 | 88.8 |
16K160 | 6.5 | 0.16 | 200 | 202.2 |
16K200 | 5.9 | 0.2 | 200 | 166.5 |
16K250 | 5.3 | 0.25 | 215 | 131.7 |
16K400 | 4.7 | 0.4 | 280 | 96.7 |
16K500 | 4.5 | 0.5 | 300 | 87.7 |
16N630 | 4.3 | 0.63 | 185 | 82.2 |
16N1000 | 3.9 | 1.0 | 230 | 62.8 |
16N1600 | 3.6 | 1.6 | 270 | 52.4 |
16N2500 | 3.4 | 2.5 | 300 | 45.6 |
16N2800 | 3.4 | 2.8 | 300 | 45.2 |
16N3300 | 3.4 | 3.3 | 300 | 44.7 |
16N4000 | 3.2 | 4.0 | 350 | 38.1 |
16N5200 | 3.2 | 5.2 | 350 | 37.7 |
16N6300 | 3.2 | 6.3 | 350 | 38.4 |
16N10000 | 3.2 | 10 | 350 | 38.9 |
Table 3 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26K8.4 | 11.8 | 0.0084 | 43 | 632.9 |
26K13.4 | 9.8 | 0.0134 | 63 | 431.5 |
26K21 | 8.8 | 0.021 | 78 | 339.0 |
26K34 | 8.0 | 0.034 | 94 | 273.7 |
26K54 | 7.1 | 0.054 | 119 | 212.4 |
26K85 | 6.4 | 0.085 | 147 | 170.2 |
26K130 | 6.0 | 0.13 | 167 | 147.8 |
26K180 | 7.9 | 0.18 | 96 | 271.9 |
26K260 | 7.4 | 0.26 | 110 | 234.2 |
26K360 | 6.8 | 0.36 | 130 | 195.5 |
26K500 | 6.4 | 0.5 | 100 | 171.2 |
26K650 | 5.9 | 0.65 | 100 | 144.8 |
26K1000 | 5.7 | 1.0 | 100 | 133.3 |
26K1300 | 6.2 | 1.3 | 100 | 160.6 |
26K2000 | 5.8 | 2.0 | 100 | 139.1 |
26K3300 | 5.4 | 3.3 | 100 | 118.8 |
26N4600 | 5.8 | 4.6 | 100 | 138.3 |
26N8000 | 5.4 | 8.0 | 100 | 118.6 |
26N13000 | 5.0 | 13.0 | 100 | 100.8 |
26N27000 | 4.8 | 27.0 | 100 | 92.1 |
26N40000 | 4.6 | 40.0 | 100 | 84.4 |
26N60000 | 4.4 | 60.0 | 100 | 77.1 |
26N72000 | 4.2 | 72.0 | 100 | 70.2 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23K210 | 5.2 | 0.21 | 222 | 117.9 |
23K300 | 4.8 | 0.3 | 261 | 98.9 |
23K400 | 4.8 | 0.4 | 261 | 97.2 |
23K480 | 4.8 | 0.48 | 261 | 96.0 |
23K650 | 4.6 | 0.65 | 284 | 87.3 |
23K1000 | 4.1 | 1.0 | 100 | 68.9 |
23K1300 | 3.8 | 1.3 | 100 | 58.9 |
23K2000 | 5.0 | 2.0 | 100 | 104.7 |
23K2400 | 4.8 | 2.4 | 100 | 95.7 |
23K3000 | 4.6 | 3.0 | 100 | 87.3 |
23N4600 | 4.8 | 4.6 | 100 | 96.3 |
23N7500 | 4.6 | 7.5 | 100 | 86.9 |
23N11200 | 4.4 | 11.2 | 100 | 78.7 |
23N14000 | 4.2 | 14.0 | 100 | 71.6 |
23N18000 | 3.6 | 18.0 | 100 | 52.6 |
23N26000 | 3.6 | 26.0 | 100 | 52.2 |
23N40000 | 3.4 | 40.0 | 100 | 46.4 |
23N50000 | 4.0 | 50.0 | 100 | 63.8 |
23N60000 | 3.6 | 60.0 | 100 | 51.7 |
23N72000 | 3.4 | 72.0 | 100 | 46.1 |
Note: the resistance value of 2-core cable in the above table is the measured value after the end is twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals.
Table 5 terminal specifications
Model: A, D, E | Model: B | |||
Maximum Voltage (V) | Maximum Current (A) | Terminal Specification | Maximum Current (A) | Terminal Specification |
600 | 15 | E2 | 20 | E1 |
600 | 20 | E2 | 25 | E2 |
600 | 30 | E3 | 40 | E2 |
600 | 50 | E3 | 70 | E2 |
600 | 70 | E3 | 100 | E3 |
Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Anticorrosive specification
Material | ||
Sulfate | Not recommend | |
Hydrochloric acid | Data checking required | |
Hydrofluoric acid | Data checking required | |
Phosphate | Data checking required | |
Carbonate | Data checking required | |
Organic acid | Data checking required | |
Alkali metal | Data checking required | |
Sea water | Excellent | |
Chloride | Excellent |
Explosion-proof instructions
MICN series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us
Leave a Message, we will call you back quickly!