Sheath Metal Sheathed
Function Easy Electrical Control
Application Gardening
Diameter up to project request
Cable Length in Meter
Power in Watt
Voltage Volt
Unit Weight Up to 184 kg/km
Brand Name MICH
Model Number CECMIHEG
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 20 million meters
Delivery Time in one month Packaging Details plywood crates
Sheath Metal Sheathed Function Easy Electrical Control
Application Gardening Diameter up to project request
Cable Length in Meter Power in Watt
Voltage Volt Unit Weight Up to 184 kg/km
Brand Name MICH Model Number CECMIHEG
Certification ISO9001 Place of Origin China
High Light MI Heating Element Of Heater8.2mm Heating Element Of HeaterMI insulated heating element

Convenient Electrical Control Mineral Insulated Heating Element for Gardening

 

 

Convenient Electrical Control Mineral Insulated Heating Element for Gardening is for applications as below:

 

1. Winter Heating for the greenhouse crops;
2. Snow icing prevention for greenhouse;
3. Heating to promote seed growth;
4. Keep warm for favoring the lawn maintenance.

 

Mineral insulation Heating Element is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable. It can be widely used on heating or heat tracing of process conveying pipes and accessories, pumps, reactor, cracking furnace, carburetor, flash evaporator, storage tank, storage tank, other devices and vessels etc.

 

 

 

 

The CML IEC Ex and ATEX explosion-proof certificates have granted for the mineral insulated heating cable products

 

.

 

Storage and handling


1. The product shall be stored in a dry room, centralized and classified, and measures shall be taken to prevent the product from mechanical damage.
2. During the storage period, it shall be inspected every three months: the appearance of the package shall be complete; the marks complete, the sealing end shall be tight, and the metal sheath shall be free from rust.
3. The ambient temperature of product storage shall be no less than -15℃, and the relative humidity shall be no more than 85%.
4. Necessary measures should be taken to prevent rain, moisture, falling and other mechanical damage during handling to prevent the products and packaging from being damaged.

 

 

Table 1 Heating Cable Specification (600V Single Conductor)

Cable Code Diameter HDPE Diameter Standard resistance value at +20 Maximum Production Length Unit weight
mm mm Ω/m m kg/km
16C1.7 8.2 10 0.0017 350 366.54
16C2.2 7.6 9.4 0.0022 380 307.77
16C2.9 7.0 8.8 0.0029 400 264.45
16C4 5.9 7.7 0.004 600 190.88
16C7 5.3 7.1 0.007 600 154.08
16C11 4.9 6.7 0.011 600 132.25
16C13 4.6 6.4 0.013 600 (300)☆ 125.7
16C17 4.6 6.4 0.017 600 (300)☆ 117.16
16C21 4.6 6.4 0.021 600 (300)☆ 111.9
16C25 3.7 5.5 0.025 600 (480)☆ 68.83
16C33 3.7 5.5 0.033 600 (480)☆ 63.76
16C40 3.4 5.2 0.04 600 (560)☆ 58.87
16C63 3.2 5 0.063 600 51.47
16K80 6.8 8.6 0.08 370 (140)☆ 254.18
16K100 5.2 7 0.1 450 (240)☆ 162.11
16K140 4.9 6.7 0.14 600 (270)☆ 122.55
16K197 4.45 6.25 0.197 600 (330)☆ 111.32
16K220 4.5 6.3 0.22 600 (330)☆ 102.89
16K315 4.3 6.1 0.315 600 (350)☆ 91.44
16K345 4.2 6.0 0.345 600 (370)☆ 85.9
16K450 4.0 5.8 0.45 600 (400)☆ 80.73
16K630 4.0 5.8 0.63 600 (400)☆ 77.26
16K800 3.5 5.3 0.8 600 (530)☆ 61.48
16K1250 2.8 4.6 1.25 600 40.83
16K2000 2.8 4.6 2.0 600 38.96

 

 

Table 2 Heating Cable Specification (600V Double Cores)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26C3.4 12.9 0.0034 150 783.76
26C4.4 12.2 0.0044 160 701.56
26C5.8 11.3 0.0058 170 606.16
26C8.6 9.90 0.0086 180 451.43
26C11.4 9.30 0.0114 200 400.05
26C13.8 9.00 0.0138 210 375.20
26C17.2 8.60 0.0172 220 344.90
26C23 8.00 0.023 250 303.25
26C34.4 7.50 0.0344 280 269.20
26C49.2 7.10 0.0492 300 243.84
26K240 9.90 0.24 180 451.43
26K320 9.30 0.32 200 400.05
26K384 9.00 0.384 210 375.20
26K480 8.60 0.48 220 344.90
26K640 8.00 0.64 250 303.25
26K960 7.50 0.96 280 269.20

 

 

Table 3 Heating Cable Specification (300V Double Cores)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23C3.4 12.0 0.0034 200 708.10
23C4.4 11.3 0.0044 220 629.07
23C5.8 10.4 0.0058 240 537.73
23C8.6 9.00 0.0086 260 392.56
23C11.4 8.40 0.0114 280 343.89
23C13.8 8.00 0.0138 300 314.57
23C17.2 7.60 0.0172 320 286.27
23C23 7.10 0.023 340 252.98
23C34.4 6.60 0.0344 360 221.19
23C49.2 6.20 0.0492 380 197.64
23K160 10.4 0.16 220 508.37
23K240 9.00 0.24 240 392.56
23K320 8.40 0.32 265 343.89
23K384 8.00 0.384 280 314.57
23K480 7.70 0.48 300 291.91
23K640 7.10 0.64 320 252.98
23K960 6.50 0.96 350 216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH

 

Table 4 terminal specifications

 

  Model: A, D, E Model: B  
Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V)
       
600 15 E2 20 E1 15 E1
600 20 E2 25 E2 20 E1
600 30 E3 40 E2 30 E2
600 50 E3 70 E2 50 E2
600 70 E3 100 E3 70 E2

 

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Employee Number:

    150~200

  • Ecer Certification:

    Active Member

Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...

+ Read More

Get in touch with us

  • Reach Us
  • Pasia Industries Ltd
  • 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
  • https://www.miheatingcables.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement