Payment Terms | L/C, T/T |
Supply Ability | 20 million meters |
Delivery Time | in one month |
Packaging Details | plywood crates |
Sheath | Metal Sheathed |
Function | Easy Electrical Control |
Application | Gardening |
Diameter | up to project request |
Cable Length | in Meter |
Power | in Watt |
Voltage | Volt |
Unit Weight | Up to 184 kg/km |
Brand Name | MICH |
Model Number | CECMIHEG |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
8.2MM Sheathed Heating Element for Chemical Industry Heating
Power Plant Mineral Insulated Heating Elements
600V Double Cores High Temperature Heating Element
300V Mineral Insulated Heating Elements Corrosion Resistant
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 20 million meters |
Delivery Time | in one month | Packaging Details | plywood crates |
Sheath | Metal Sheathed | Function | Easy Electrical Control |
Application | Gardening | Diameter | up to project request |
Cable Length | in Meter | Power | in Watt |
Voltage | Volt | Unit Weight | Up to 184 kg/km |
Brand Name | MICH | Model Number | CECMIHEG |
Certification | ISO9001 | Place of Origin | China |
High Light | MI Heating Element Of Heater ,8.2mm Heating Element Of Heater ,MI insulated heating element |
Convenient Electrical Control Mineral Insulated Heating Element for Gardening
Convenient Electrical Control Mineral Insulated Heating Element for Gardening is for applications as below:
1. Winter Heating for the greenhouse crops;
2. Snow icing prevention for greenhouse;
3. Heating to promote seed growth;
4. Keep warm for favoring the lawn maintenance.
Mineral insulation Heating Element is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable. It can be widely used on heating or heat tracing of process conveying pipes and accessories, pumps, reactor, cracking furnace, carburetor, flash evaporator, storage tank, storage tank, other devices and vessels etc.
The CML IEC Ex and ATEX explosion-proof certificates have granted for the mineral insulated heating cable products
.
Storage and handling
1. The product shall be stored in a dry room, centralized and classified, and measures shall be taken to prevent the product from mechanical damage.
2. During the storage period, it shall be inspected every three months: the appearance of the package shall be complete; the marks complete, the sealing end shall be tight, and the metal sheath shall be free from rust.
3. The ambient temperature of product storage shall be no less than -15℃, and the relative humidity shall be no more than 85%.
4. Necessary measures should be taken to prevent rain, moisture, falling and other mechanical damage during handling to prevent the products and packaging from being damaged.
Table 1 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 2 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 3 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Table 4 terminal specifications
Model: A, D, E | Model: B | |||||
Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) |
600 | 15 | E2 | 20 | E1 | 15 | E1 |
600 | 20 | E2 | 25 | E2 | 20 | E1 |
600 | 30 | E3 | 40 | E2 | 30 | E2 |
600 | 50 | E3 | 70 | E2 | 50 | E2 |
600 | 70 | E3 | 100 | E3 | 70 | E2 |
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us
Leave a Message, we will call you back quickly!