Supply Ability | 10 million meters per year |
Delivery Time | in one month |
Packaging Details | plywood crates |
Conductor | Copper |
Sheath | Copper-Nickel |
Components | Connected with power cable |
Function | Heating or Heat Trace |
Diameter | 3.2-11.8 mm |
Nominal resistance at +20℃ | 0.0021-10 |
Maximum Length | Up to 375 meters |
Terminal Maximum Voltage | 600 V |
Brand Name | MICH |
Model Number | MIHCE |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
8.2MM Sheathed Heating Element for Chemical Industry Heating
Power Plant Mineral Insulated Heating Elements
Convenient Electrical Control MI Heating Element Of Heater
600V Double Cores High Temperature Heating Element
Product Specification
Supply Ability | 10 million meters per year | Delivery Time | in one month |
Packaging Details | plywood crates | Conductor | Copper |
Sheath | Copper-Nickel | Components | Connected with power cable |
Function | Heating or Heat Trace | Diameter | 3.2-11.8 mm |
Nominal resistance at +20℃ | 0.0021-10 | Maximum Length | Up to 375 meters |
Terminal Maximum Voltage | 600 V | Brand Name | MICH |
Model Number | MIHCE | Certification | ISO9001 |
Place of Origin | China | ||
High Light | Alloy Sheath Mineral Insulated Heating Elements ,11.8mm Mineral Insulated Heating Elements ,11.8mm heating element of heater |
Copper-Nickel Alloy Sheath Mineral Insulated Heating Element for Industries
Mineral Insulated Heating Cables of Cu-Ni alloy sheathed series can meet the requirements of high temperature conditions and long-distance pipelines. The maximum temperature of copper-nickel alloy sheathed heating cable provided by MICH can reach a temperature up to 400℃. Conductor resistance value ranges from 4 Ω/km to 28000 Ω/km. Mineral insulated cable has excellent mechanical strength and corrosion resistance. The heating cable of series resistance provided by MICH can meet the requirements of different powers.
Cable Structure
Application
Cu-Ni Alloy Sheathed Mineral Insulated Heating Cable series are mainly used on petrochemical plant, chemical plant, power plant, natural gas storage, pharmaceutical plant, etc.
Specifications
Heating cable instruction code
MI CN-B 16K239/60/2520/220/E1
NO. 1 2 3 4 5 6 7
No. | Instruction | |
1 | Sheath material | Cu-Ni |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Cable Code
1 6 K 239
No. 1 2 3 4
NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | K,N,C |
4 | cold resistance ×1000 | 239=0.239Ω/m×1000 |
Table 1 Structure of Cable Element
Table 2 Heating Cable Specification (600V Single Core)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
16C2.1 | 6.8 | 0.0021 | 130 | 220.7 |
16C3.4 | 5.9 | 0.0034 | 173 | 162.5 |
16C5.3 | 5.3 | 0.0053 | 214 | 125.6 |
16C8.5 | 4.8 | 0.0085 | 261 | 101.6 |
16C13 | 4.3 | 0.013 | 325 | 79.1 |
16C21 | 4.0 | 0.021 | 376 | 65.8 |
16K40 | 5.8 | 0.04 | 179 | 157.1 |
16K50 | 5.4 | 0.05 | 206 | 135.6 |
16K60 | 5.2 | 0.06 | 222 | 122.8 |
16K80 | 4.8 | 0.08 | 261 | 101.2 |
16K100 | 4.7 | 0.1 | 200 | 99.5 |
16K120 | 4.5 | 0.12 | 200 | 88.8 |
16K160 | 6.5 | 0.16 | 200 | 202.2 |
16K200 | 5.9 | 0.2 | 200 | 166.5 |
16K250 | 5.3 | 0.25 | 215 | 131.7 |
16K400 | 4.7 | 0.4 | 280 | 96.7 |
16K500 | 4.5 | 0.5 | 300 | 87.7 |
16N630 | 4.3 | 0.63 | 185 | 82.2 |
16N1000 | 3.9 | 1.0 | 230 | 62.8 |
16N1600 | 3.6 | 1.6 | 270 | 52.4 |
16N2500 | 3.4 | 2.5 | 300 | 45.6 |
16N2800 | 3.4 | 2.8 | 300 | 45.2 |
16N3300 | 3.4 | 3.3 | 300 | 44.7 |
16N4000 | 3.2 | 4.0 | 350 | 38.1 |
16N5200 | 3.2 | 5.2 | 350 | 37.7 |
16N6300 | 3.2 | 6.3 | 350 | 38.4 |
16N10000 | 3.2 | 10 | 350 | 38.9 |
Table 3 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26K8.4 | 11.8 | 0.0084 | 43 | 632.9 |
26K13.4 | 9.8 | 0.0134 | 63 | 431.5 |
26K21 | 8.8 | 0.021 | 78 | 339.0 |
26K34 | 8.0 | 0.034 | 94 | 273.7 |
26K54 | 7.1 | 0.054 | 119 | 212.4 |
26K85 | 6.4 | 0.085 | 147 | 170.2 |
26K130 | 6.0 | 0.13 | 167 | 147.8 |
26K180 | 7.9 | 0.18 | 96 | 271.9 |
26K260 | 7.4 | 0.26 | 110 | 234.2 |
26K360 | 6.8 | 0.36 | 130 | 195.5 |
26K500 | 6.4 | 0.5 | 100 | 171.2 |
26K650 | 5.9 | 0.65 | 100 | 144.8 |
26K1000 | 5.7 | 1.0 | 100 | 133.3 |
26K1300 | 6.2 | 1.3 | 100 | 160.6 |
26K2000 | 5.8 | 2.0 | 100 | 139.1 |
26K3300 | 5.4 | 3.3 | 100 | 118.8 |
26N4600 | 5.8 | 4.6 | 100 | 138.3 |
26N8000 | 5.4 | 8.0 | 100 | 118.6 |
26N13000 | 5.0 | 13.0 | 100 | 100.8 |
26N27000 | 4.8 | 27.0 | 100 | 92.1 |
26N40000 | 4.6 | 40.0 | 100 | 84.4 |
26N60000 | 4.4 | 60.0 | 100 | 77.1 |
26N72000 | 4.2 | 72.0 | 100 | 70.2 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23K210 | 5.2 | 0.21 | 222 | 117.9 |
23K300 | 4.8 | 0.3 | 261 | 98.9 |
23K400 | 4.8 | 0.4 | 261 | 97.2 |
23K480 | 4.8 | 0.48 | 261 | 96.0 |
23K650 | 4.6 | 0.65 | 284 | 87.3 |
23K1000 | 4.1 | 1.0 | 100 | 68.9 |
23K1300 | 3.8 | 1.3 | 100 | 58.9 |
23K2000 | 5.0 | 2.0 | 100 | 104.7 |
23K2400 | 4.8 | 2.4 | 100 | 95.7 |
23K3000 | 4.6 | 3.0 | 100 | 87.3 |
23N4600 | 4.8 | 4.6 | 100 | 96.3 |
23N7500 | 4.6 | 7.5 | 100 | 86.9 |
23N11200 | 4.4 | 11.2 | 100 | 78.7 |
23N14000 | 4.2 | 14.0 | 100 | 71.6 |
23N18000 | 3.6 | 18.0 | 100 | 52.6 |
23N26000 | 3.6 | 26.0 | 100 | 52.2 |
23N40000 | 3.4 | 40.0 | 100 | 46.4 |
23N50000 | 4.0 | 50.0 | 100 | 63.8 |
23N60000 | 3.6 | 60.0 | 100 | 51.7 |
23N72000 | 3.4 | 72.0 | 100 | 46.1 |
Note: the resistance value of 2-core cable in the above table is the measured value after the end is twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals.
Table 5 terminal specifications
Model: A, D, E | Model: B | |||
Maximum Voltage (V) | Maximum Current (A) | Terminal Specification | Maximum Current (A) | Terminal Specification |
600 | 15 | E2 | 20 | E1 |
600 | 20 | E2 | 25 | E2 |
600 | 30 | E3 | 40 | E2 |
600 | 50 | E3 | 70 | E2 |
600 | 70 | E3 | 100 | E3 |
Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Anticorrosive specification
Material | ||
Sulfate | Not recommend | |
Hydrochloric acid | Data checking required | |
Hydrofluoric acid | Data checking required | |
Phosphate | Data checking required | |
Carbonate | Data checking required | |
Organic acid | Data checking required | |
Alkali metal | Data checking required | |
Sea water | Excellent | |
Chloride | Excellent |
Explosion-proof instructions
MICN series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us