China Antifreeze Mineral Insulated Copper Sheathed Cable
China Antifreeze Mineral Insulated Copper Sheathed Cable

  1. China Antifreeze Mineral Insulated Copper Sheathed Cable
  2. China Antifreeze Mineral Insulated Copper Sheathed Cable

Antifreeze Mineral Insulated Copper Sheathed Cable

  1. MOQ: 1 meter
  2. Price: USD0.5-USD5 per meter
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 20 million meters
Delivery Time in one month
Packaging Details plywood crates
Sheath Copper
Function Freeze Prevention
Application Metal Gutters and Downpipes
Diameter up to project request
Cable Length in Meter
Power in Watt
Vottage Volt
Unit Weight Up to 184 kg/km
Brand Name MICH
Model Number MIHCCSLD
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 20 million meters
Delivery Time in one month Packaging Details plywood crates
Sheath Copper Function Freeze Prevention
Application Metal Gutters and Downpipes Diameter up to project request
Cable Length in Meter Power in Watt
Vottage Volt Unit Weight Up to 184 kg/km
Brand Name MICH Model Number MIHCCSLD
Certification ISO9001 Place of Origin China
High Light Antifreeze Mineral Insulated Copper Sheathed Cable250 ℃ Mineral Insulated Copper Sheathed Cable600V mi heating cable

Copper Sheathed MI Heating Cable for Freeze Prevention for Metal Gutters and Downpipes can meet the needs of high temperature condition and heat tracing of long-distance transportation pipeline. The maximum withstand temperature of the copper sheathed heating cable (MICU) provided by MICH can reach up to 250℃. Conductor resistance value ranges from 1.7-2000Ω/km. For the occasion of anti-corrosion or buried application, high density polyethylene (HDPE) outer sheath ( cable known as MIHC) is needed to be added. MIHC’s withstanding maximum temperature can be up to 90℃. Mineral insulated heating cable possesses excellent mechanical strength. The heating cable of series resistance provided by MICH can meet the requirements of different power levels.

 

 

Cable Structure

Application

Copper sheathed heating cable (MICU) Maximum output power(W/m)
Freezing Prevention for metal gutters and downpipes 49
Freezing Prevention for non-metal gutters and downpipes 16
Vessel and piping process temperature maintaining 59
Freezing Prevention for metal containers and pipes 59
Metal roof snow-melting 49
High-density polyethylene outer sheathed copper sheathed heating cable (MIHC)  
Freezing Prevention for metal containers and pipes 26
Freezing Prevention non-metallic containers and pipes 13
Snow melting on asphalt slopes 82
Non-metallic roof ice or snow melting 26
Freezing Prevention for metal gutters and downpipes 26
Freezing Prevention for non - metallic gutters and downpipes 16
Concrete floor heating 33
Rising or defrosting prevention for cold storage ground 23
Freezing Prevention for metal containers and pipes 99

Note: when heating cables are used for heat tracing of vessels and pipes, the maximum output power must be controlled to ensure that the sheath temperature does not exceed its maximum allowable temperature or the spontaneous combustion temperature of the area (for hazardous areas).

 

Specification

Heating cable instruction code

 

MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

No. Instruction  
1 Sheath material CU
2 structure of cable components shown in table 1
3 cable codes shown in table 2, 3 and 4
4 length of heating cable In meter
5 Heating cable power In Watt
6 heating cable voltage In Volt
7 heating cable voltage See table 5

 

 

 

 

 

 

 

 

 

 

 

Cable Code

1 6 K 320

No. 1 2 3 4

Serial NO. Instruction  
1 core number 1 or 2
2 Voltage grade 3=300V, 6=600V
3 conductor materials C,K
4 cold resistance ×1000 320=0.32Ω/m×1000

 

 

 

 

 

 

 

Table 1 Structure of Cable Element

Note: Model C, F and G are suitable for being used at temperature under 65

 

表格 2 加热电缆规格 (600V 单芯)

Cable Code Diameter HDPE Diameter Standard resistance value at +20 Maximum Production Length Unit weight
mm mm Ω/m m kg/km
16C1.7 8.2 10 0.0017 350 366.54
16C2.2 7.6 9.4 0.0022 380 307.77
16C2.9 7.0 8.8 0.0029 400 264.45
16C4 5.9 7.7 0.004 600 190.88
16C7 5.3 7.1 0.007 600 154.08
16C11 4.9 6.7 0.011 600 132.25
16C13 4.6 6.4 0.013 600 (300)☆ 125.7
16C17 4.6 6.4 0.017 600 (300)☆ 117.16
16C21 4.6 6.4 0.021 600 (300)☆ 111.9
16C25 3.7 5.5 0.025 600 (480)☆ 68.83
16C33 3.7 5.5 0.033 600 (480)☆ 63.76
16C40 3.4 5.2 0.04 600 (560)☆ 58.87
16C63 3.2 5 0.063 600 51.47
16K80 6.8 8.6 0.08 370 (140)☆ 254.18
16K100 5.2 7 0.1 450 (240)☆ 162.11
16K140 4.9 6.7 0.14 600 (270)☆ 122.55
16K197 4.45 6.25 0.197 600 (330)☆ 111.32
16K220 4.5 6.3 0.22 600 (330)☆ 102.89
16K315 4.3 6.1 0.315 600 (350)☆ 91.44
16K345 4.2 6.0 0.345 600 (370)☆ 85.9
16K450 4.0 5.8 0.45 600 (400)☆ 80.73
16K630 4.0 5.8 0.63 600 (400)☆ 77.26
16K800 3.5 5.3 0.8 600 (530)☆ 61.48
16K1250 2.8 4.6 1.25 600 40.83
16K2000 2.8 4.6 2.0 600 38.96

 

 

Table 3 Heating Cable Specification (600V Double Cores)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26C3.4 12.9 0.0034 150 783.76
26C4.4 12.2 0.0044 160 701.56
26C5.8 11.3 0.0058 170 606.16
26C8.6 9.90 0.0086 180 451.43
26C11.4 9.30 0.0114 200 400.05
26C13.8 9.00 0.0138 210 375.20
26C17.2 8.60 0.0172 220 344.90
26C23 8.00 0.023 250 303.25
26C34.4 7.50 0.0344 280 269.20
26C49.2 7.10 0.0492 300 243.84
26K240 9.90 0.24 180 451.43
26K320 9.30 0.32 200 400.05
26K384 9.00 0.384 210 375.20
26K480 8.60 0.48 220 344.90
26K640 8.00 0.64 250 303.25
26K960 7.50 0.96 280 269.20

 

 

Table 4 Heating Cable Specification (300V Double Cores)

 

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23C3.4 12.0 0.0034 200 708.10
23C4.4 11.3 0.0044 220 629.07
23C5.8 10.4 0.0058 240 537.73
23C8.6 9.00 0.0086 260 392.56
23C11.4 8.40 0.0114 280 343.89
23C13.8 8.00 0.0138 300 314.57
23C17.2 7.60 0.0172 320 286.27
23C23 7.10 0.023 340 252.98
23C34.4 6.60 0.0344 360 221.19
23C49.2 6.20 0.0492 380 197.64
23K160 10.4 0.16 220 508.37
23K240 9.00 0.24 240 392.56
23K320 8.40 0.32 265 343.89
23K384 8.00 0.384 280 314.57
23K480 7.70 0.48 300 291.91
23K640 7.10 0.64 320 252.98
23K960 6.50 0.96 350 216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH

 

Table 5 terminal specifications

 

  Model: A, D, E Model: B  
Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V)
       
600 15 E2 20 E1 15 E1
600 20 E2 25 E2 20 E1
600 30 E3 40 E2 30 E2
600 50 E3 70 E2 50 E2
600 70 E3 100 E3 70 E2

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

 

Corresponding reference table between the output power and sheath temperature

 

 

Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.

 

Anticorrosive specification

 

Material

MICU

MIHC
Sulfate Not recommend Excellent
Hydrochloric acid Not recommend Excellent
Hydrofluoric acid Acceptable Acceptable
Phosphate Acceptable Acceptable
Carbonate Not recommend Acceptable
Organic acid Acceptable Not recommend
Alkali metal Acceptable Acceptable
Sea water Not recommend Acceptable
Chloride Data checking required Acceptable

 

Explosion-proof instructions

 

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.

 

 

 

MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Employee Number:

    150~200

  • Ecer Certification:

    Active Member

Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...

+ Read More

Get in touch with us

  • Reach Us
  • Pasia Industries Ltd
  • 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
  • https://www.miheatingcables.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement