Payment Terms | L/C, T/T |
Supply Ability | 50 SET/PER MONTHS |
Delivery Time | 35~45Days |
Packaging Details | WOODEN CASE |
Accuracy | 0.05 Class |
RSM | 0.05% Class |
Positions | 16 meterss |
Current Source | 1mA~120A |
Brand Name | SHENGDI TECHNOLOGY |
Model Number | HS-6303 |
Certification | CNAS,SGS. |
Place of Origin | ZHEJIANG.CHINA |
View Detail Information
Explore similar products
Three-phase DIN-rail KWh Energy Meter Test Bench,active & reactive,3P4W ,Max
16 Positions Three Phase Electric Electricity Energy Meter Test Bench,0.05%
HS6303C Three Phase Electrical Meter Test Equipment(Calibration Test Bench)
HS6303E Three Phase KWH Meter Testing Equipment With ICT(Close Link) 6 Position
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 50 SET/PER MONTHS |
Delivery Time | 35~45Days | Packaging Details | WOODEN CASE |
Accuracy | 0.05 Class | RSM | 0.05% Class |
Positions | 16 meterss | Current Source | 1mA~120A |
Brand Name | SHENGDI TECHNOLOGY | Model Number | HS-6303 |
Certification | CNAS,SGS. | Place of Origin | ZHEJIANG.CHINA |
Test Bench Three Phase Energy Meter (HS6303)
General
1) The bench accords with the standard of "IEC 60736: 1982 testing equipment for electrical energy meters", "IEC 62053"
2) The bench can be used to test both single/three phase active energy meter and reactive energy meter (up to 0.2 Class), it is also suitable for four quadrant energy meter testing.
3) The bench can do warm up test, starting test, no load test(creep test), error test (accuracy test), dial test, tests of the influence quantities(reverse phase, voltage unbalance, harmonic wave and so on) and test of repeatability of the measurements.
4) The bench is using the PWM to amplify voltage/current output, the high efficiency at >85%, and lower the heat. The PWM can check the malfunction checking, preset, alarm, and protection
5) The signal source is using the newest digital controlled sine wave technology for frequency, amplitude and phase adjust. The signal source can repeatedly add 2-21 harmonics on the first sine wave, or cause sub-harmonic wave and odd subharmonic wave.
6) The bench is using the HS 5300 reference standard energy meter with comparison technology to offer the accuracy of energy meters.
7) The bench is using the error processor system to calculate the error of each energy meter by the sub-error system, which can be connected by the internal RS485.
8) The same specification but different constant energy meter can be tested at one time.
9) The test bench can be installed scanning head, it can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
10) The test bench has the auto-search black marker function which can precisely locate the black marker during the no load test and starting test.
11) The bench can choose to operate by keyboard or PC which is very convenient. The working status of bench can be seen very clear and easy operation.
12) The bench is using the testing software complied with WINDOWS98/2000/XP which can auto-testing different energy meters.
13) The software can realize the data from energy meter for statistics, search and management.
14) The energy meter hanging rack is made by Aluminum compound. The whole device configuration is a reasonable design and nice outfit
Technical Specification
1) The test bench accuracy class: 0.05/0.1
2) Reference standard energy meter:
HS5300 Three Phase Reference Standard Meter
Accuracy class: 0.05 /0.1
3) Voltage amplifier:
Output voltage range: 0-300V(phase-neutral);
Output maximum power: 800VA
Resolution: 0.01%;
Stability: Better than 0.05%/3 min(time base 5S);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: More than 85%;
Ambient temperature: 10C~50C
Electronic overload and short-circuit protection.
4) Current amplifier:
Output current: Range: 1mA~120A (option for 1mA~200A);
Output maximum power: 1500VA
Resolution: 0.01%;
Stability: Better than 0.05%/3 min (time base 5S);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: Greater than 85%;
Ambient temperature: 10C~50C
Electronic overload protection and security for open current circuit.
5) Phase Angle: 0° ~360° , resolution of phase angle setting: 0.1° ;
6) Output frequency range: 45Hz~65Hz; Resolution: 0.01Hz
7) Harmonic wave output: 2-21 sub-harmonic wave contents≤ 40%
3, 5, 7 sub-harmonic wave coupling, total content≤ 40%
Phase angle control (odd sub-harmonic wave)
Wave group control (sub-harmonic wave)
8) Output stability of power: <0.05% (180S)
9) Numbers of calibrated energy meter: 16 (6/8/12/16/20/24/32 on requested)
10) Input power: 3× 220V/380V (Y) 15%, 50/60Hz; Max. Power consumption: 6000VA
Dimensions(unit:mm)
Integration | stations | Number of rack | dimension:L×W×H | Fission | stations | Number of rack | dimension:L×W×H |
6 | 1 | 2000×800×1600 | 12 | 1 | 2000×700×1920 | ||
CUSTOM | 16 | 1 | 2200×700×1920 | ||||
12 | 1 | 2000×800×1920 | 24 | 2 | 2000×700×1920 | ||
16 | 1 | 2200×800×1920 | 32 | 2 | 2200×700×1920 | ||
24 | 2 | 2000×750×1920 | cabinet | 600×800×1920 |
Products Details:
REFERENCE METER(HS-5300)
SIGNAL SOURCE:(HS-6633)
QUICK CONNECTOR
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2007
Total Annual:
5,000,000-10,000,100
Employee Number:
200~500
Ecer Certification:
Active Member
We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ...
Get in touch with us
Leave a Message, we will call you back quickly!