Payment Terms | TT,LC |
Supply Ability | 30 SET/45 DAYS |
Delivery Time | 35~45days |
Packaging Details | WOODEN CASE |
POSITION | 24 meters |
Current MAX | 200A & 100A |
Accuracy | 0.05% |
RSM | HS-5302H Three-phase |
Brand Name | SHENGDI TECHNOLOGY |
Model Number | HS-6303E |
Certification | GS,CNAS |
Place of Origin | ZHEJIANG,CHINA |
View Detail Information
Explore similar products
ANSI SOCKET FORM2S Meter Test Bench,24 Position 1mA~120A current output,30~300V
ANSI SOCKET FORM 1S,2S,9S,12S,16S Three-phase electric meter test equipment 24
Single phase kwh Meter test bench with 24 meters capable to test with 12 IEC and
HS-6103G ANSI Single Phase Watt-hour Meter Testing Device(1P2W) Manually
Product Specification
Payment Terms | TT,LC | Supply Ability | 30 SET/45 DAYS |
Delivery Time | 35~45days | Packaging Details | WOODEN CASE |
POSITION | 24 meters | Current MAX | 200A & 100A |
Accuracy | 0.05% | RSM | HS-5302H Three-phase |
Brand Name | SHENGDI TECHNOLOGY | Model Number | HS-6303E |
Certification | GS,CNAS | Place of Origin | ZHEJIANG,CHINA |
HS-6303 THREE-PHASE ENERGY METER TEST BENCH
Overview:
HS-6303 three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.
This testing bench configurations humanized PC processing software, can provide an integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.
This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.
This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.
Functional advantage:
Technical Parameters:
Parameter Item | 0.02 | 0.05 | 0.1 |
Reference standard energy meter | HS-5300H 0.02 | HS-5300 0.05 | HS-5300 0.1 |
Output range | Voltage: 3×30~300V Current: 3×1mA~120A | Voltage: 3×30~300V Current: 3×10mA~120A(200A) | |
Output phase shift | 0~360°,resolution:0.01° | ||
Output frequency | 45~65Hz ,resolution:0.01Hz | ||
Waveform distortion | Both Voltage and current<0.5%( relative liner load) | ||
Voltage ¤t power stability | <0.02%/120s | <0.05%/120s | <0.1%/120s |
Output capacity | Voltage:200VA(6 stations)Current: 250VA(120A) | Voltage:300VA(16 stations) current:900VA(120A) Max. voltage: 1200VA | |
Load characteristics | Resistive, inductive and capacitive(less than 1uF/station,Max. less than 48uF) | ||
Starting up current output | Min.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5% | ||
sampling pulse input | ≤1kHz | ||
Communication testing | RS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107 | ||
Number of energy meters to be tested | 6/16(standard),3-60 (optional) | ||
Environment condition | temperature:20℃±5℃;humility:<85% R.H. | ||
Power supply | AC220V ±10%,50/60Hz,AC120/240V(optional); |
Dimensions(unit:mm)
integration | stations | Number of rack | dimension:L×W×H | fission | stations | Number of rack | dimension:L×W×H |
6 | 1 | 2000×800×1600 | 12 | 1 | 2000×700×1920 | ||
CUSTOMIZED | 16 | 1 | 2200×700×1920 | ||||
12 | 1 | 2000×800×1920 | 24 | 2 | 2000×700×1920 | ||
16 | 1 | 2200×800×1920 | 32 | 2 | 2200×700×1920 | ||
24 | 2 | 2000×750×1920 | cabinet | 600×800×1920 |
Type & specification
type | description | Range of application |
HS-6303 | three-phase energy meter testing bench | Standard energy meter testing |
HS-6303B | three-phase multi-function energy meter testing bench | Multi-function energy meter testing |
HS-6303C | three-phasehorizontal energy meter calibration bench | Energy meter error calibration |
HS-6303E | three-phase energy meter test bench with ICTS | 1P3W energy meter testing |
HS-6303F | three-phase intelligent energy meter testing bench | intelligent energy meter testing |
HS-6303G | three-phase energy meter (round meter) testing bench | Standard energy meter testing |
HS-6303M | three-phase din-rail energy meter testing bench | Multi-function energy meter testing |
HS-6303H | three-phase high precision energy meter testing bench | Energy meter error calibration |
Function parameters:
Function item | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H | |
Base testing functions | Base error | ● | ● | ● | ● | ● | ● | ● | ● |
Creep testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Starting up testing | ● | ● | ● | ● | ● | ● | ● | ● | |
standard deviation | ● | ● | ● | ● | ● | ● | ● | ● | |
Constant calibration | ● | ● | ● | ● | ● | ● | ● | ● | |
Counting error | ● | ● | ● | ● | ● | ● | ● | ● | |
Influencing testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Multi-function testing | Daily timing error☆ | ● | 〇 | 〇 | ● | 〇 | |||
Period switching | ● | 〇 | ● | 〇 | |||||
Demand period error | ● | ● | |||||||
Demand display error | ● | ● | |||||||
Energy display error | ● | ● | |||||||
register checking | ● | ● | |||||||
GPS clock synchronization☆ | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
Communication testing☆ | ● | 〇 | 〇 | ● | 〇 | 〇 | 〇 |
For Item ☆ need special function parts
Bench configuration
Type | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H |
Standard energy meter | ● | ● | ● | ● | ● | ● | ● | ● |
power source | ● | ● | ● | ● | ● | ● | ● | ● |
error processing system | ● | ● | ● | ● | ● | ● | ● | ● |
multi-path pulse input | ● | 〇 | ● | ● | 〇 | 〇 | ||
Auto searching mark | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
auto short circuit | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
ICT | ● | |||||||
parallel communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
carrier communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
IR communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
power consumption testing | 〇 | 〇 | ||||||
DC and even harmonic wave | 〇 | 〇 | ||||||
standard clock tester | ● | 〇 | 〇 | ● | 〇 | |||
GPS clock synchronization | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
collective turn over & optoelectronic sampling | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
PACKING DETAILS: WOODEN CASE
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2007
Total Annual:
5,000,000-10,000,100
Employee Number:
200~500
Ecer Certification:
Active Member
We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ...
Get in touch with us
Leave a Message, we will call you back quickly!