Packaging Details | Wooden Case |
Delivery Time | 15 days |
Payment Terms | TT/LC |
Supply Ability | 300 |
Place of Origin | China |
Brand Name | Shengdi Electrical |
Certification | ISO9001:2008 |
Model Number | HS9503 |
View Detail Information
Explore similar products
Product Specification
Packaging Details | Wooden Case | Delivery Time | 15 days |
Payment Terms | TT/LC | Supply Ability | 300 |
Place of Origin | China | Brand Name | Shengdi Electrical |
Certification | ISO9001:2008 | Model Number | HS9503 |
HS-9503 Three Phase Isolated Current Transformer
Technical Specifications
Pic 1 the method of connection of isolated CT picture
When you test the return circle of three phase meter, the current and voltage are closed links, which you need to isolate them. As for the multi-position power meter auto-calibration system, it should add the three phase isolated current transformer: HS-9503.
At present, this kind of testing return circle current and voltage closed links power meter, and widely used in productive and application, even the numbers are still amplified. If the connection I-P of testing return circle can’t divided the current and voltage ,and through the circle it make the failed connection for every verified meters.
Therefore, the return current through the isolated transformer to separate , in order to improve the efficient of verifying and testing , as for the isolated connection energy meter, sometimes also hope testing them during the unisolated condition.
Phase should install the isolated transformer on each verified energy meter position.
The variable percentage of isolating transformer is 1:1, and phase place its error enough small range have in the whole range, can bring the obvious additional error in measuring.
Main Characteristics
• Wide electric current range:0.05A… 120A;
• Maximum transmission power: max. 60VA;
•Adopt the electronic error to compensate, guarantee accuracy;
•Overload indication.
Range of Application
• At multi-position check-up device , measure electric current and voltage return circuit can separating or electric energy meter not separated;
• Carry on the transformation to the existing check-up device.
Ordinary Index
• Auxiliary voltage:220V±15% 50/60Hz±5%, max. 10VA.
• Machine case: The metal case body assembles three and isolates the transformer of electric current.
• Weight: 14.5kg.
• Working environment tempreture:+10℃~+40℃.
• Function environment tempreture:-10℃~+50℃.
• Store tempreture:-40℃~+80℃.
Transformational Index
• Nominal frequency:50Hz/60Hz±5%
• Elementary current:0.05~120A
• Secondary current:0.05~120A
Output load
• Output power: max. 60VA.
• Output load:
Output range:0.05~1A 0.5Ω.
Outputrage:1~120A 0.5V divided by the present current value.
• Output load voltage: max 0.5V.
Error
• transformation ratio error :≤0.05%.
• Angular Error :≤1min.
• Active power error :≤0.10%(COSφ=0.5C~1~0.5L).
• P1,P2,P3:
Radiation the indicator lamp is shine: this circle is normal; otherwise the light is dim: it means that the circle is abnormal .
• PRO: warning the output outlet, I1, I2, I3 relevant current return circle output the warning signal (Lead the notice to export alertly) I1-I,I2-I,I3-I: isolated CT current input the terminal for one time.
• I1-COM,I2-COM,I3-COM isolated CT current input the terminal for primary.
• I1-o, I2-o, I3-o: isolated Ct current output the terminal for second time.
• COM1, COM2, COM3 isolated CT current output the terminal for second time.
• Several isolated CT connect the first time connect each other,and at second time to solo test the return circuit of power supply
• Dimension:200mm×220mm×220mm.
Contact: Yeli
Email: hysdsales@gmail.com
Skype: lily19850618
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2007
Total Annual:
5,000,000-10,000,100
Employee Number:
200~500
Ecer Certification:
Active Member
We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ...
Get in touch with us