Payment Terms | L/C, T/T |
Supply Ability | 50 SET/PER MONTHS |
Delivery Time | 35~45Days |
Packaging Details | WOODEN CASE |
Accuracy | 0.05% Class |
Voltage | 50~480V |
Positions | 6 Positions |
Current Source | 3* 1mA-200A |
Meter | Single Three Phase Meter |
Brand Name | SHENGDI TECHNOLOGY |
Model Number | HS-6303 |
Certification | CNAS,SGS. |
Place of Origin | ZHEJIANG.CHINA |
View Detail Information
Explore similar products
Three-phase DIN-rail KWh Energy Meter Test Bench,active & reactive,3P4W ,Max
16 Positions Three Phase Electric Electricity Energy Meter Test Bench,0.05%
HS6303C Three Phase Electrical Meter Test Equipment(Calibration Test Bench)
HS6303E Three Phase KWH Meter Testing Equipment With ICT(Close Link) 6 Position
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 50 SET/PER MONTHS |
Delivery Time | 35~45Days | Packaging Details | WOODEN CASE |
Accuracy | 0.05% Class | Voltage | 50~480V |
Positions | 6 Positions | Current Source | 3* 1mA-200A |
Meter | Single Three Phase Meter | Brand Name | SHENGDI TECHNOLOGY |
Model Number | HS-6303 | Certification | CNAS,SGS. |
Place of Origin | ZHEJIANG.CHINA |
HS-6303 three-phase energy meter testing bench
SUIT FOR "CT METER" & Single-phase/Three-phase meter
HS-6303 three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.
This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.
This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.
This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.
CLASS | 0.02 | 0.05 | 0.1 |
Reference standard energy meter | HS-5300H 0.02 | HS-5300 0.05 | HS-5300 0.1 |
Output range | Voltage:3×30~300V Current:3×1mA~120A | Voltage:3×30~300V Current:3×10mA~120A(200A Option) | |
Output phase shift | 0~360°,resolution:0.01° | ||
Output frequency | 45~65Hz ,resolution:0.01Hz | ||
Waveform distortion | Both Voltage and current<0.5%( relative liner load) | ||
Voltage ¤t power stability | <0.02%/120s | <0.05%/120s | <0.1%/120s |
Output capacity | Voltage:300VA(6 stations) Current:250VA(120A) | Voltage:300VA(16 stations)current:900VA(120A) | |
Load characteristics | Resistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF) | ||
Starting up current output | Min.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5% | ||
sampling pulse input | ≤1kHz | ||
Communication testing | RS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107 | ||
Number of energy meters to be tested | 6/16(standard),3-60 (optional) | ||
Environment condition | temperature:20℃±5℃;humility:<85% R.H. | ||
Power supply | AC220 ±10%,50/60Hz,AC120/240V(optional); |
Integration | stations | Number of rack | dimension:L×W×H | Fission | stations | Number of rack | dimension:L×W×H |
6 | 1 | 2000×800×1600 | 12 | 1 | 2000×700×1920 | ||
CUSTOM | 16 | 1 | 2200×700×1920 | ||||
12 | 1 | 2000×800×1920 | 24 | 2 | 2000×700×1920 | ||
16 | 1 | 2200×800×1920 | 32 | 2 | 2200×700×1920 | ||
24 | 2 | 2000×750×1920 | cabinet | 600×800×1920 |
Description | Range of application | |
HS-6303 | three-phase energy meter testing bench | Standard energy meter testing |
HS-6303B | three-phase multi-function energy meter testing bench | Multi-function energy meter testing |
HS-6303C | three-phase horizontal energy meter calibration bench | Energy meter error calibration |
HS-6303E | three-phase energy meter test bench with ICTS | 1P3W energy meter testing |
HS-6303F | three-phase intelligent energy meter testing bench | intelligent energy meter testing |
HS-6303G | three-phase energy meter (round meter) testing bench | Standard energy meter testing |
HS-6303M | three-phase din-rail energy meter testing bench | Multi-function energy meter testing |
HS-6303H | three-phase high precision energy meter testing bench | Energy meter error calibration |
Function item | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H | |
Base testing functions | Base error | ● | ● | ● | ● | ● | ● | ● | ● |
Creep testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Starting up testing | ● | ● | ● | ● | ● | ● | ● | ● | |
standard deviation | ● | ● | ● | ● | ● | ● | ● | ● | |
Constant calibration | ● | ● | ● | ● | ● | ● | ● | ● | |
Counting error | ● | ● | ● | ● | ● | ● | ● | ● | |
Influencing testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Multi-function testing | Daily timing error☆ | ● | 〇 | 〇 | ● | 〇 | |||
Period switching | ● | 〇 | ● | 〇 | |||||
Demand period error | ● | ● | |||||||
Demand display error | ● | ● | |||||||
Energy display error | ● | ● | |||||||
register checking | ● | ● | |||||||
GPS clock synchronization☆ | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
Communication testing☆ | ● | 〇 | 〇 | ● | 〇 | 〇 | 〇 |
For Item ☆ need special function parts
Type | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H |
Standard energy meter | ● | ● | ● | ● | ● | ● | ● | ● |
power source | ● | ● | ● | ● | ● | ● | ● | ● |
error processing system | ● | ● | ● | ● | ● | ● | ● | ● |
multi-path pulse input | ● | 〇 | ● | ● | 〇 | 〇 | ||
Auto searching mark | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
auto short circuit | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
ICT | ● | |||||||
parallel communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
carrier communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
IR communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
power consumption testing | 〇 | 〇 | ||||||
DC and even harmonic wave | 〇 | 〇 | ||||||
standard clock tester | ● | 〇 | 〇 | ● | 〇 | |||
GPS clock synchronization | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
collective turn over & optoelectronic sampling | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
PRODUCTS DETAILS:
Technical Specification: Kwh meter test bench with capacity to test at least 6 energy meter in one single batch comprising of following functions: 1.Ability to test single phase and three phase KWH meters for ★Constant test(Register test) ★ Error test ★No-load test ★Creep test ★Start Test ★ Variation tests for voltage,frequency and harmonics test 2. Manual control with tablet or Computer through a delicated software 3. Individual adjustment for voltage,current and phase angles 4.Range: ★ Voltage range: 3*30~300V ★ Current range:3*0.01~120A 5.Voltage and current adjustment limit:0%~120% if range. 6.Phase adjustament limit: 0~360° 7.Frequency adjustment limit: 45Hz~65Hz 8.Power Stability:≤0.05%/120s 9.Distortion:≤0.5% 10.Harmonic Setting: 2~21st Harmonic,Content:≤40% 11.Active power phase shift:0~360° 12.Power supply: AC220V +/-10%,50/60Hz. Ask for pirce: hysdsales@gmail.com ![]() ![]() |
CALIBRATION CERTIFICATION
As customer's requirement,we can supply 3rd part calibration certification. with CNAS mark.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2007
Total Annual:
5,000,000-10,000,100
Employee Number:
200~500
Ecer Certification:
Active Member
We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ...
Get in touch with us
Leave a Message, we will call you back quickly!