China Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A
China Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A

  1. China Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A
  2. China Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A
  3. China Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A

Three phase test Bench Class 0.05,16 meter positions with Ct,HS-6303E,0.1~120A

  1. MOQ: 1 SET
  2. Price: USD$1~100000/SET
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 50 SET/PER MONTHS
Delivery Time 35~45Days
Packaging Details WOODEN CASE
Accuracy 0.05% Class
Voltage 57.7V,100V,220V,380V
Positions 16 Positions
Current Source 0.1A~120A
Brand Name SHENGDI TECHNOLOGY
Model Number HS-6303E
Certification CNAS,SGS.
Place of Origin ZHEJIANG.CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 50 SET/PER MONTHS
Delivery Time 35~45Days Packaging Details WOODEN CASE
Accuracy 0.05% Class Voltage 57.7V,100V,220V,380V
Positions 16 Positions Current Source 0.1A~120A
Brand Name SHENGDI TECHNOLOGY Model Number HS-6303E
Certification CNAS,SGS. Place of Origin ZHEJIANG.CHINA

HS-6303E THREE PHASE ENERGY METER TEST BENCH-16 Position

SUIT FOR "CT &DC METER" & Single-phase/Three-phase meter

 

1.OVERVIEW

 

HS-6303E three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by the customer.

This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

This series of the testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.

 

2. APPLICABLE STANDARDS

 

IEC 60736 Testing equipment for electrical energy meters.

 

3. GENERAL TECHNICAL SPECIFICATION

 

3.1 Power Source

 

 

Voltage amplifier

No. DESCRIPTION MEASURMENT
1 Electronic protection against Overload and Short Circuit
2 LED indication for faults like overload,short circuit and power supply failure will display
3 Efficiency Better than 85%.
4 Stability <0.05%/120s
5 Distortion factor < 0.5 %.
6 Provision for super-imposing of harmonics in the range of 2 nd to 21th harmonic
7 Test voltage range 30~300V
8 Output Power Not less than 1000VA
9 Accuracy of the test setting amplitude 0.05 %
10 Accuracy of the test setting phase adjustment 0.01 °

 

Current amplifier

No. DESCRIPTION MEASURMENT
1 Electronic protection against Overload and Short Circuit
2 LED indication for faults like overload,short circuit and power supply failure will display
3 Efficiency Better than 85%.
4 Stability <0.05%/120s
5 Distortion factor < 0.5 %.
6 Provision for super-imposing of harmonics in the range of 2 nd to 21th harmonic
7 Test current range 1mA~120A
8 Output Power Not less than 1500VA
9 Accuracy of the test setting amplitude 0.05 %
10 Accuracy of the test setting phase adjustment 0.01 °
 

 

 

3.2 Reference Meter(Standard Meter)-HS-5300 Three Phase Reference Meter

 

3.3 Isolated Current Transformer

 

ISOLATED CURRENT TRANSFORMER(ICT)

 

Isolated Current Transformer Equipment:(HS-9503B)

HS-9503B Isolated current inductance

Accuracy class: 0.01 (COSφ=0.5C-1-0.5L,0.1~120A)

Primary current: 3×0.025mA~120A secondary current: 3×0.025mA~120A

Output power: 60VA (MAX,120A)

 

 

3.4 CALIBRATION CERTIFICATION

 

As customer's requirement,we can supply 3rd part calibration certification. with CNAS mark.

 

16 position Three Phase Electric Meter Test Bench,Output Current: 4* 0-120A, one current circuit for neutral current

16 position Three Phase Electric Meter Test Bench,Output Current: 4* 0-120A, one current circuit for neutral current

16 position Three Phase Electric Meter Test Bench,Output Current: 4* 0-120A, one current circuit for neutral current16 position Three Phase Electric Meter Test Bench,Output Current: 4* 0-120A, one current circuit for neutral current

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2007

  • Total Annual:

    5,000,000-10,000,100

  • Employee Number:

    200~500

  • Ecer Certification:

    Active Member

We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench)                Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench       ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench)                Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench       ...

+ Read More

Get in touch with us

  • Reach Us
  • Zhejiang Shengdi Technology Inc.
  • #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County
  • http://metertesting-biz.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement