China Online Temperature And Pressure Flow Monitor Flow Integrated Monitor
China Online Temperature And Pressure Flow Monitor Flow Integrated Monitor

  1. China Online Temperature And Pressure Flow Monitor Flow Integrated Monitor
  2. China Online Temperature And Pressure Flow Monitor Flow Integrated Monitor
  3. China Online Temperature And Pressure Flow Monitor Flow Integrated Monitor

Online Temperature And Pressure Flow Monitor Flow Integrated Monitor

  1. MOQ: 1
  2. Price: Negotiate
  3. Get Latest Price
Delivery Time 5 working days after payment
Supply Ability 3000 Piece/Pieces per Month mini flow meter
Packaging Details carton or customers requests available
Payment Terms T/T, Western Union
Model Number BT590178
Place of Origin CHINA
Brand Name BEITE
Certification CE ISO

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote

Explore similar products

  1. Product Details
  2. Company Details

Product Specification

Delivery Time 5 working days after payment Supply Ability 3000 Piece/Pieces per Month mini flow meter
Packaging Details carton or customers requests available Payment Terms T/T, Western Union
Model Number BT590178 Place of Origin CHINA
Brand Name BEITE Certification CE ISO
High Light liquid flow monitorTemperature And Pressure Flow Monitorflow integrated monitor

BT-TPF-565 online temperature and pressure flow monitor (temperature and pressure flow integrated machine)

BT-TPF-565 online temperature and pressure flow monitor (temperature and pressure flow integrated machine) is an important measurement of flue gas temperature, pressure and flow rate in the continuous monitoring system of concentration and total emission of gaseous pollutants and particulate matter emitted by atmospheric pollution sources. The equipment uses a real-flow calibrated pitot tube to measure the flow rate of high-temperature gases. The equipment comes with an automatic purging function, which overcomes the shortcomings of traditional pitot tubes that are prone to clogging in humid and dusty flue gas. The basic principle of the Pitot tube is that the gas flowing in the pipe is affected by both static pressure and dynamic pressure. The static pressure is the potential energy of the gas per unit volume, which is expressed as the pressure of the gas acting on the pipe wall in all directions; the dynamic pressure is The kinetic energy per unit volume of gas is the pressure that causes the gas to flow. Since dynamic pressure only acts in the direction of gas flow, the dynamic pressure is positive, and the gas flow rate is proportional to the square root of the gas dynamic pressure. Therefore, the gas flow rate is calculated based on the measured dynamic pressure.

The BT-TPF-565 temperature and pressure flow integrated monitor (temperature and pressure flow integrated machine) has a high-precision differential pressure/static pressure sensor and is equipped with a backflush unit controlled by a solenoid valve. It is specially designed for continuous monitoring of flue gas emissions. The integrated temperature, pressure, and flow rate monitor developed for high dust, high temperature, and high humidity environments meets the requirements of relevant standards and can be used in flue gas emission monitoring systems (CEMS) for real-time monitoring of flue gas temperature, pressure, flow rate, and flow rate. Continuous measurement.


 Technical features of BT-TPF-565 online temperature, pressure and flow monitor:

One-piece structure that can be quickly assembled and disassembled, flange-type installation, simple structure;

Small size, simple and compact structure, low maintenance, and small installation space required.

Automatic timing or manual zero calibration of dynamic pressure and flow rate;

The LCD displays each measurement data and signal, which can be read directly for easy debugging (optional);

High measurement accuracy, good reliability, and can work continuously for a long time;

Equipped with an automatic backflush unit that can regularly clean particles in the pitot tube to prevent clogging, and the backflush time interval can be set;

 Basis for design standards

HJ 1012-2018 Ambient air and exhaust gas Technical requirements and detection methods for portable monitors of total hydrocarbons, methane and non-methane total hydrocarbons

HJ 38-2017 "Determination of stationary pollution source exhaust gas, non-methane total hydrocarbons, methane and non-methane non-methane total hydrocarbons - Gas chromatography method"

HJ 75-2017 "Technical Specifications for Continuous Monitoring of Flue Gas (SO2, NOX, Particulate Matter) Emissions from Stationary Pollution Sources"

HJ 76-2017 "Technical Requirements and Testing Methods for Continuous Monitoring System for Flue Gas (SO2, NOX, Particulate Matter) Emissions from Stationary Pollution Sources"


  Technical indicators of BT-TPF-565 online temperature, pressure and flow monitor:

Flue gas flow speed: 0~40m/s;

Flue gas dynamic pressure: 0~1000Pa;

Flue gas static pressure: 80~120kPa (absolute pressure);

Flue gas temperature range: -40~500℃; Ambient temperature: -40~85℃;

Signal output: 4~20mA square root proportional current, two-wire system;

Resolution output: 0.125%FS;

Flow rate accuracy: ±5%FS;

Dynamic pressure accuracy: ±2%FS;

Static pressure accuracy: ±1%FS;

Temperature accuracy: ±1%FS;

Differential pressure transmitter overpressure limit: 16MPa; Pitot tube material: 304, 316L stainless steel;

Backflush solenoid valve power supply: 220VAC, 50Hz; Pitot tube insertion length: 500mm~1700mm optional; purge time can be set.

Pressure transmitter range: -10~10kPa or other customized ranges; Temperature transmitter range: 0~600°C or other customized ranges;

Storage temperature: -40~80℃; Storage humidity: 0~85%RH.​Packing & Delivery
Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Verified Supplier

Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit... Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Beite Smart Instrument Co., Ltd
  • No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
  • https://www.meter-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement