China factories

China factory - Suzhou Beite Smart Instrument Co., Ltd

Suzhou Beite Smart Instrument Co., Ltd

  • China,Suzhou ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Electromagnetic Flowmeter Manual
China Electromagnetic Flowmeter Manual

  1. China Electromagnetic Flowmeter Manual
  2. China Electromagnetic Flowmeter Manual
  3. China Electromagnetic Flowmeter Manual
  4. China Electromagnetic Flowmeter Manual
  5. China Electromagnetic Flowmeter Manual
  6. China Electromagnetic Flowmeter Manual

Electromagnetic Flowmeter Manual

  1. MOQ: 1 Piece/Pieces
  2. Price: Negotiate
  3. Get Latest Price
Delivery Time 5 working days after payment
Supply Ability sufficient goods
Packaging Details carton or customers requests available
Payment Terms T/T, Western Union
Range ratio 1:30(0.5m/s~15m/s)
Applicable medium liquid
Display mode Liquid crystal display
Maximum velocity 15m/s
Nominal pressure 0.6~4 Mpa
Nominal diameter 3~3000
Place of Origin CHINA
Brand Name BEITE
Certification CE ISO

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 5 working days after payment Supply Ability sufficient goods
Packaging Details carton or customers requests available Payment Terms T/T, Western Union
Range ratio 1:30(0.5m/s~15m/s) Applicable medium liquid
Display mode Liquid crystal display Maximum velocity 15m/s
Nominal pressure 0.6~4 Mpa Nominal diameter 3~3000
Place of Origin CHINA Brand Name BEITE
Certification CE ISO
High Light electro magnetic flowmetermag sus metermag flow meter

Pulse Output
Two types of pulse output are available to choose from: frequency output mode and pulse output mode. The meter outputs continuous square wave pulse under frequency mode, while pulse series under pulse mode. Frequency output is usually used for flow rate measurement and short period of time totalization. Pulse output can be connected to an external counter directly and is often used for long period of time totalization.
As mentioned hereinbefore, transistor open collector circuit is used for frequency and pulse output. Therefore, the external DC power supply and load are necessary.

 

Features
1. Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
2. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
3. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
4. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
5. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
6. High definition LCD display with backlight.
7. RS485 or RS232 interface supports digital communication.
8. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
9. SMD component and surface mount technology (SMT) are implemented to improve the reliability.

 

Main Applications

TQMF electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry. 1.3Ambient Conditions Ambient temperature: sensor: -25℃ to + 60℃; converter: -25℃ to + 60℃. Relative humidity: 5% to 90%; 1.4Working Conditions Maximum fluid temperature: Compact type: 60℃ Remote type: Teflon 150℃ Neoprene 80℃; 120℃ Polyurethane 70℃ Fluid conductivity: ≥ 5S/cm

 

Measuring Principles

The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 0

Converter Circuit Schematic

The converters supplies a stable exciting current to the coil in the sensor of electronetic flowmeters to get B constant and amplifies the electromotive force and convert it into standard signals of current or frequency so that the signals can be used for displaying, controlling and processing. The schematic of converter circuit is shown in Fig. 2.1.

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 1

 

Table of Parameter Setting Menu

The converter setting menu consists of 45 items. Many of them are set up by manufacturer before shipping. It is not necessary to change them when applying. There are only a few of them to be set by user according to the application. The menu items are listed in the table below:

Item No. Menu Display Setting Method Password Level Value Range
1 Language Option 1 Chinese/English
2 Sensor Size Option 1 3 - 3000mm
3 Flow Range Modify 1 0 - 99999
4 Auto Rng Chg Option 1 ON / OFF
5 Damping Option 1 0 - 100 s
6 Flow Dir. Option 1 Fwd/ Res
7 Flow Zero Modify 1 +/-0.000
8 L.F. Cutoff Modify 1 0 - 99%
9 Cutoff Enble Option 1 ON / OFF
10 Rate-Of-Chng Modify 1 0 - 30%
11 Limit Time Modify 1 0 - 20 s
12 Total Unit Option 1 0.0001L - 1 m3
13 Flow Density Modify 1 0.0000 - 3.9999
14 Current Type Option 1 4-20mA/0-10mA
15 Pulse Output Option 1 Frq/ Pulse
16 Pulse Factor Option 1 0.001L - 1 m3
17 Freq Max Modify 1 1 - 5999 Hz
18 Comm Address Modify 1 0 - 99
19 Baudrate Option 1 600 - 14400
20 EmpPipe Det. Option 1 ON / OFF
21 EmpPipe Alm Modify 1 200.0 KΩ
22 Hi ALM Enble Option 1 ON / OFF
23 Hi Alm Limit Modify 1 000.0 - 199.9%
24 Lo Alm Enble Option 1 ON / OFF
25 Lo Alm Limit Modify 1 000.0 - 199.9%
26 RevMeas.Enbl Option 1 ON/OFF
27 Sensor S/N Modify 2 000000000000-999999999999
28 Sensor Fact. Modify 2 0.0000 - 3.9999
29 Field Mode Option 2 Mode 1,2,3
30 Multiplying Modify 2 0.0000 - 3.9999
31 F. Total Set Modify 3 0000000000 - 9999999999
32 R.Total Set Modify 3 0000000000 - 9999999999
33 Input Contrl Option 3 Disable/Stop Tot/Reset Tot
34 Clr Totalizr Password 3 00000 - 59999
35 Clr Tot. Key Modify 3 00000 - 59999
36 Date –y/m/d * Modify 3 99/12/31
37 Time-h/m/s * Modify 3 23/59/59
38 Password L1 Modify 3 0000 - 9999
39 Password L2 Modify 3 0000 - 9999
40 Password L3 Modify 3 0000 - 9999
41 Current Zero Modify 4 0.0000 - 1.9999
42 Current Max Modify 4 0.0000 - 3.9999
43 Meter Factor Modify 4 0.0000 - 3.9999
44 Convtr S/N Modify 4 0000000000-9999999999
45 Sys Reset Password 4  

 

Scenario application:

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 2Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 3Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 4Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 5Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 6

 

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Verified Supplier

Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit... Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Beite Smart Instrument Co., Ltd
  • No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
  • https://www.meter-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement