China Wastewater Pipe Sewage Flow Meter
China Wastewater Pipe Sewage Flow Meter

  1. China Wastewater Pipe Sewage Flow Meter
  2. China Wastewater Pipe Sewage Flow Meter

Wastewater Pipe Sewage Flow Meter

  1. MOQ: 1 Piece/Pieces
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 3000 Piece/Pieces per Month mini flow meter
Delivery Time 5 working days after payment
Packaging Details carton or customers requests available
Range ratio 1:30(0.5m/s~15m/s)
Applicable medium liquid
Display mode Liquid crystal display
Maximum velocity 15m/s
Nominal pressure 0.6~4 Mpa
Nominal diameter 3~3000
Brand Name BEITE
Certification CE ISO
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 3000 Piece/Pieces per Month mini flow meter
Delivery Time 5 working days after payment Packaging Details carton or customers requests available
Range ratio 1:30(0.5m/s~15m/s) Applicable medium liquid
Display mode Liquid crystal display Maximum velocity 15m/s
Nominal pressure 0.6~4 Mpa Nominal diameter 3~3000
Brand Name BEITE Certification CE ISO
Place of Origin CHINA
High Light Wastewater Flow MetersSewage flowmeterflow meter pipe

The display mode of electromagnetic flowmeter is divided into: split type electromagnetic flowmeter, integrated type electromagnetic flowmeter

According to the display mode, electromagnetic flowmeters are divided into: split type electromagnetic flowmeter and integrated type electromagnetic flowmeter. Series nominal diameter DN15 ~ DN3000.
The split-type electromagnetic flowmeter is an inductive instrument that measures the volume flow of conductive media in a pipe based on Faraday's law of electromagnetic induction. It uses microcontroller embedded technology to realize digital excitation. At the same time, it uses CAN fieldbus on the electromagnetic flowmeter, which is the first in China. The technology has reached the domestic leading level.
The split-type electromagnetic flowmeter not only meets the needs of on-site display, but also can output 4-20mA current signals for recording, adjustment and control. It is now widely used in chemical industry, environmental protection, metallurgy, medicine, papermaking, water supply and drainage and other industrial technology and management department.
In addition to measuring the flow of general conductive liquids, the split-type electromagnetic flowmeter can also measure the volume flow of liquid-solid two-phase flow, high-viscosity liquid flow, and salt, strong acid, and strong alkali liquids.
The integrated electromagnetic flowmeter is formulated based on Faraday's law of electromagnetic induction and is used to measure the volume flow of conductive fluids. Due to its unique characteristics, it has been widely used in the measurement of various conductive liquids in industry. It is mainly used in chemical industry, papermaking, food, textile, metallurgy, environmental protection, water supply and drainage and other industries. It can realize system control when matched with computers.

 

Electromagnetic flowmeter installation requirements
1. For horizontal and vertical flow directions, the electromagnetic flowmeter should be installed at the lower part of the horizontal pipe and the vertical upward part, and avoid installing it at the highest point and vertical downward part of the pipe;

2. When the flow direction is inclined, the electromagnetic flowmeter should be installed at the rising point of the pipe;

3. When opening the discharge pipe, the electromagnetic flowmeter should be installed at the lower part of the pipe;

4. When the pipeline drop exceeds 5 meters, an exhaust valve should be installed downstream of the electromagnetic flowmeter;

5. The control valve and cut-off valve on the pipeline should be installed downstream of the electromagnetic flowmeter and should not be installed upstream of the sensor;

6. The electromagnetic flowmeter cannot be installed at the inlet of the pump, but should be installed at the outlet;

7. How to install electromagnetic flowmeter in the measuring well;

 

Features
1. Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
2. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
3. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
4. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
5. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
6. High definition LCD display with backlight.
7. RS485 or RS232 interface supports digital communication.
8. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
9. SMD component and surface mount technology (SMT) are implemented to improve the reliability.

 

Main Applications

TQMF electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry. 1.3Ambient Conditions Ambient temperature: sensor: -25℃ to + 60℃; converter: -25℃ to + 60℃. Relative humidity: 5% to 90%; 1.4Working Conditions Maximum fluid temperature: Compact type: 60℃ Remote type: Teflon 150℃ Neoprene 80℃; 120℃ Polyurethane 70℃ Fluid conductivity: ≥ 5S/cm

 

L.F. Cutoff and Cutoff Enble
Low flow cutoff is set in percentage relative to flow range. If Cutoff is enabled and flow is lower than the set value, the display of flow rate, speed and percentage and signal outputs are forced to nil. If the item is disabled, no action is taken.

 

Measuring Principles

The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 0

Converter Circuit Schematic

The converters supplies a stable exciting current to the coil in the sensor of electronetic flowmeters to get B constant and amplifies the electromotive force and convert it into standard signals of current or frequency so that the signals can be used for displaying, controlling and processing. The schematic of converter circuit is shown in Fig. 2.1.

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 1

 

Table of Parameter Setting Menu

The converter setting menu consists of 45 items. Many of them are set up by manufacturer before shipping. It is not necessary to change them when applying. There are only a few of them to be set by user according to the application. The menu items are listed in the table below:

Item No. Menu Display Setting Method Password Level Value Range
1 Language Option 1 Chinese/English
2 Sensor Size Option 1 3 - 3000mm
3 Flow Range Modify 1 0 - 99999
4 Auto Rng Chg Option 1 ON / OFF
5 Damping Option 1 0 - 100 s
6 Flow Dir. Option 1 Fwd/ Res
7 Flow Zero Modify 1 +/-0.000
8 L.F. Cutoff Modify 1 0 - 99%
9 Cutoff Enble Option 1 ON / OFF
10 Rate-Of-Chng Modify 1 0 - 30%
11 Limit Time Modify 1 0 - 20 s
12 Total Unit Option 1 0.0001L - 1 m3
13 Flow Density Modify 1 0.0000 - 3.9999
14 Current Type Option 1 4-20mA/0-10mA
15 Pulse Output Option 1 Frq/ Pulse
16 Pulse Factor Option 1 0.001L - 1 m3
17 Freq Max Modify 1 1 - 5999 Hz
18 Comm Address Modify 1 0 - 99
19 Baudrate Option 1 600 - 14400
20 EmpPipe Det. Option 1 ON / OFF
21 EmpPipe Alm Modify 1 200.0 KΩ
22 Hi ALM Enble Option 1 ON / OFF
23 Hi Alm Limit Modify 1 000.0 - 199.9%
24 Lo Alm Enble Option 1 ON / OFF
25 Lo Alm Limit Modify 1 000.0 - 199.9%
26 RevMeas.Enbl Option 1 ON/OFF
27 Sensor S/N Modify 2 000000000000-999999999999
28 Sensor Fact. Modify 2 0.0000 - 3.9999
29 Field Mode Option 2 Mode 1,2,3
30 Multiplying Modify 2 0.0000 - 3.9999
31 F. Total Set Modify 3 0000000000 - 9999999999
32 R.Total Set Modify 3 0000000000 - 9999999999
33 Input Contrl Option 3 Disable/Stop Tot/Reset Tot
34 Clr Totalizr Password 3 00000 - 59999
35 Clr Tot. Key Modify 3 00000 - 59999
36 Date –y/m/d * Modify 3 99/12/31
37 Time-h/m/s * Modify 3 23/59/59
38 Password L1 Modify 3 0000 - 9999
39 Password L2 Modify 3 0000 - 9999
40 Password L3 Modify 3 0000 - 9999
41 Current Zero Modify 4 0.0000 - 1.9999
42 Current Max Modify 4 0.0000 - 3.9999
43 Meter Factor Modify 4 0.0000 - 3.9999
44 Convtr S/N Modify 4 0000000000-9999999999
45 Sys Reset Password 4  

 

Scenario application:

Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 2Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 3Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 4Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 5Intelligent electromagnetic flow meter pipeline measurement sewage slurry measurement 4-20  mA display 6

 

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Verified Supplier

Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit... Suzhou Beite Smart Instrument Co., Ltd. was established in 2007.It is an automated instrument manufacturer integrating R&D, design, manufacturing, sales and system complete services.   After years of development, the company's new factory covers an area of ​​15 acres, wit...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Beite Smart Instrument Co., Ltd
  • No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
  • https://www.meter-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement