China Stable and Accurate Stationary Meter Test Bench with Better Than 0.005%/h
China Stable and Accurate Stationary Meter Test Bench with Better Than 0.005%/h

  1. China Stable and Accurate Stationary Meter Test Bench with Better Than 0.005%/h

Stable and Accurate Stationary Meter Test Bench with Better Than 0.005%/h

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, D/P
Supply Ability 100/Year
Model NO. YC1891D
After-sales Service 3 Year
Warranty 1 Year
Application Electromagnetic Instrument
Power Electricity
Voltage Output 24V-300V(or Customized)
Current Output 1mA-120A/200A
Thermocouple (TC) No
Resistance-Temperature Detector (RTD) No
LCD Display With LCD Display
Customized Customized
Trademark GENY
Transport Package Plywood Case
Specification 10.7CBM
Origin China
HS Code 9030849000
Port Guangzhou, China
Brand Name GENY
Model Number YC1891D
Certification ISO, CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, D/P Supply Ability 100/Year
Model NO. YC1891D After-sales Service 3 Year
Warranty 1 Year Application Electromagnetic Instrument
Power Electricity Voltage Output 24V-300V(or Customized)
Current Output 1mA-120A/200A Thermocouple (TC) No
Resistance-Temperature Detector (RTD) No LCD Display With LCD Display
Customized Customized Trademark GENY
Transport Package Plywood Case Specification 10.7CBM
Origin China HS Code 9030849000
Port Guangzhou, China Brand Name GENY
Model Number YC1891D Certification ISO, CE
Place of Origin CHINA
High Light Stationary Meter Test BenchStable Stationary Meter Test BenchAccurate Stationary Meter Test Bench

Stable and Accurate Stationary Meter Test Bench with Better Than 0.005%/h Stability

Our sophisticated meter assessment system is engineered to evaluate a broad spectrum of meters, encompassing mechanical, electromechanical, and electronic types, with the flexibility for fully automated, semi-automated, or manual control. It is capable of assessing single-phase meters configured in 1P2W setups and provides an array of assessment methods such as active power, reactive power, and interlaced reactive power.

Specification :

 

  YC1891D-6 YC1891D-12 YC1891D-24 YC1891D-48
Number of meter positions 6 12 24 48
Accuracy 0.05
Power Source YCS-101-250 YCS-101-600 YCS-101-1200 YCS-101-2500
Standard Meter SZ01A-K3
MSVT HJ200GL-6 HJ200GL-12 HJ200GL-24 HJ200GL-48
QCD D5 series
Scanning Head YCG-2 series
Voltage
Test voltage output 24V – 288V or customized
Power of the voltage output 100VA 250VA 500VA 1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Current
Test current output 1mA – 100A or customized,Max.200A 1mA – 100A
Power of the current output 150VA 350VA 750VA 1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz – 65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits
 
Voltage Supply

220V±10% or customized

50/60Hz±2Hz

3x220/380V±10% or customized

50/60Hz±2Hz

Ambient temperature -10°C -- +40°C
Relative humidity 35% -- 85%

 

Key Features:

  • Single-phase meter evaluation with I-P connectivity through MSVT technology.
  • A current output selector for the optional calibration of dual-element meters.
  • Concurrent assessment of meters with similar specifications but different constants.
  • Automated alignment of mechanical meter rotor marks to boost operational efficiency.
  • Functions for initiating tests and performing incremental assessments.
  • Comprehensive safeguarding against excessive loads, electrical shorts, and broken current paths.
  • Streamlined operation with synchronized scanning mechanisms.
  • Robust aluminum alloy framework for a lightweight, sturdy, and corrosion-resistant structure.
  • Intuitive software compatible with Windows 2000/XP/7/8/10, featuring modules for error analysis, harmonic assessment, demand measurement, and influence measurement.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement