China YC-1893R High-grade Three-phase Energy Meter Calibration Device
China YC-1893R High-grade Three-phase Energy Meter Calibration Device

  1. China YC-1893R High-grade Three-phase Energy Meter Calibration Device

YC-1893R High-grade Three-phase Energy Meter Calibration Device

  1. MOQ: 1
  2. Price: Negotiate rates
  3. Get Latest Price
Payment Terms T/T, L/C, D/P, T/T
Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks
Packaging Details Plywood cases
Structure All-in-one
Usage Energy Meter Calibration, Lab Research
Ambient Temperature -10℃ to +40℃
Power Supply 3P4W 3×380V±10%, 50Hz±2Hz
Ambient Humidity 35% to 85% R.H.
Voltage Resolution 0.001%
Brand Name GENY
Model Number YC-1893R
Certification ISO, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/P, T/T Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks Packaging Details Plywood cases
Structure All-in-one Usage Energy Meter Calibration, Lab Research
Ambient Temperature -10℃ to +40℃ Power Supply 3P4W 3×380V±10%, 50Hz±2Hz
Ambient Humidity 35% to 85% R.H. Voltage Resolution 0.001%
Brand Name GENY Model Number YC-1893R
Certification ISO, CE Place of Origin China
High Light High-grade Energy Meter Calibration DeviceThree-phase Energy Meter Calibration DeviceYC-1893R Energy Meter Calibration Device

YC-1893R High-grade Three-phase Energy Meter Calibration Device

The YC-1893R series of three-phase energy standard verification devices is a high-grade three-phase standard device developed by our company, reaching an international advanced level. The overall accuracy class reaches 0.01, and it is tailored for national-level and provincial and municipal metrological institutes, electric science institutes, and energy meter manufacturing factories. It is mainly used to establish primary standards or to verify the working standards of standard meters.

Specifications

Device Accuracy Class 0.01% or 0.02%
Power Supply 3P4W 3×380V±10%, 50Hz±2Hz
Ambient Temperature -10℃ ... +40℃ (Standard Operating Temperature: 20℃±1℃)
Ambient Humidity 35% ... 95% (Standard Operating Humidity: 50%R.H±15%R.H)
Output Voltage Range (L-N) 3×40V ... 450V
Output Voltage Power 3×200VA
Voltage Resolution 0.001%
Voltage Stability 0.002%/120s
Load Change Rate 0.01%
Voltage Distortion 0.05% (Across the Entire Linear Load Range)
Output Current Range 3×1mA ... 120A (Up to 230A Current as Per Customer Request)
Output Current Power 3×300VA
Current Resolution 0.001%
Current Stability 0.002%/120s
Current Distortion 0.05% (Across the Entire Linear Load Range)
Phase Adjustment Range 0° ... 360°
Phase Resolution 0.01°
Frequency Adjustment Range 45Hz ... 65Hz
Frequency Resolution 0.001Hz
Power Output Stability 0.002%/120s
Continuous Current 100A
Maximum Continuous Current for 20 Minutes 120A
Frequency Response 2MHz
Error Display Method LED Display (One Display Window per Meter Position)

 

Regular Features

  • Active Power, Reactive Power, Active Energy, and Reactive Energy measurement capabilities.

  • Start-up and inrush current testing features.
  • Automatic color marking for efficient inrush and start-up testing procedures.
  • Measurement of basic error, average error, standard deviation, and 24-hour variation.
  • Assessment of voltage influence, frequency influence, harmonic impact (2nd to 21st order), and phase sequence impact.
  • Simultaneous measurement of standard energy meters with identical current and voltage but different constants.
  • Protection against open-circuit current and short-circuit voltage.
  • Dual operation modes: automatic and manual.
  • Automatic error data processing and organization by computer software, with data storage and online output capabilities.
  • Advanced data management and statistical functions, with the ability to print reports in various formats based on user requirements.
  • Support for barcode input to streamline operations.
  • Special power supply treatment to eliminate beat frequency phenomena within the device's operational frequency range.
  • Customizable device appearance and structure tailored to customer site specifications.

Special Features

  • Bidirectional active and reactive error testing.
  • SW-5D precision time base source for measuring energy meter daily timing errors.
  • Communication testing and broadcast synchronization.
  • Verification of constants (three methods: pulse count, time, and start/end energy).
  • Time-of-use switching, demand period, and demand value error testing.
  • Meter reading and meter combination error testing.
  • Four-quadrant reactive power testing.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement