Payment Terms | T/T, L/C, D/P, T/T |
Supply Ability | 2 sets/ 3 months |
Delivery Time | 6~8weeks |
Packaging Details | Plywood cases |
Communication Protocol | Modbus RTU, Modbus TCP, DNP3.0 |
Control Software | Graphical user interface (GUI) |
Dimensions | Customizable based on customer's requirements |
Test Frequency | 50Hz/60Hz |
Accuracy Level | 0.05%, 0.1%, 0.2% |
Testing Standards | IEC 62053-21, IEC 62053-22, IEC 62053-23 |
Power Supply | 220V/110V, 50Hz/60Hz |
Application | Energy meter testing |
Operating System | Windows |
Test Voltage Range | 0-500V |
Test Current Range | 0-200A |
Function | Automatically test energy meters for accuracy and functionality |
Brand Name | GENY |
Model Number | YCATS II |
Certification | ISO, CE |
Place of Origin | China |
View Detail Information
Explore similar products
High-Capacity Automated Metering CT Test System with Safe and Reliable Block
Single Phase Energy Meter Calibration Equipment For Single Energy Meter
Maximize Efficiency And Reliability Of EV Charging With Our Comprehensive Test
YCSS-101 Single Phase Automatic Test & Calibration Power Source Line
Product Specification
Payment Terms | T/T, L/C, D/P, T/T | Supply Ability | 2 sets/ 3 months |
Delivery Time | 6~8weeks | Packaging Details | Plywood cases |
Communication Protocol | Modbus RTU, Modbus TCP, DNP3.0 | Control Software | Graphical user interface (GUI) |
Dimensions | Customizable based on customer's requirements | Test Frequency | 50Hz/60Hz |
Accuracy Level | 0.05%, 0.1%, 0.2% | Testing Standards | IEC 62053-21, IEC 62053-22, IEC 62053-23 |
Power Supply | 220V/110V, 50Hz/60Hz | Application | Energy meter testing |
Operating System | Windows | Test Voltage Range | 0-500V |
Test Current Range | 0-200A | Function | Automatically test energy meters for accuracy and functionality |
Brand Name | GENY | Model Number | YCATS II |
Certification | ISO, CE | Place of Origin | China |
High Light | Polyphase Energy Meter Automatic Test Pipeline ,Accuracy Energy Meter Automatic Test Pipeline |
This is a 3-phase automatic test line featuring a power cabinet (model: YC1893D) and 20 test stations. Each station is equipped with an Isolated Current Transformer (ICT model: TICT-100) for independent operation. The automated system utilizes pneumatic drive and includes a robotic arm.
Application Conditions and Requirements | |||||
Environment | Power Requirement | Safety | |||
Operation Temperature | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
-10°C--+40ºC | 35%--85% | <2500m | 3x220/380V±10% (or customized) 50/60Hz±2Hz | IP30 | CE conform |
Type | YCS-103-250 | YCS-103-800 | YCS-103-1200 | YCS-203-2500 |
Voltage | ||||
Test voltage output(Phase-Neutral) | 3x(24V-300V)(or customized) | |||
Power of the voltage output | Max.3x100VA | Max.3x250VA | Max.3x500VA | Max.3x1000VA |
Resolution | Better than 0.01%of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h(integration time 150 s) | |||
Load regulation from 0-max.load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd-41st free programmable | |||
Current | ||||
Test current output | 3x(1mA-120A/200A) | |||
Power of the current output | Max.3x250VA | Max.3x500VA | Max.3x1000VA | Max.3x2000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05%at the final range value | |||
Stability | Better than 0.005%/h(integration time 150 s) | |||
Load regulation from 0-max.load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd-41st free programmable | |||
Phase angle | ||||
Range | 0-360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz-65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of the error displays | 8 digits |
*If you want to know more please check our official website:http://www.genymetertestequipment.com/
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!