China factories

China factory - Guangzhou GENY Electric Co., Ltd

Guangzhou GENY Electric Co., Ltd

  • China,Guangzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services
China YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services

  1. China YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM / ODM Services

  1. MOQ: 1
  2. Price: Negotiate rates
  3. Get Latest Price
Payment Terms T/T, L/C, D/P, T/T
Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks
Packaging Details Plywood cases
Test voltage output 3×(24V – 288V) or customized
Power of the voltage output 3×100VA/3×250VA/3×500VA/3×1000VA
Test current output 3×(1mA – 100A)
Phase angle range 0 -- 360°
Relative humidity 35% -- 85%
Ambient temperature -10°C -- +40°C
Voltage Supply 3×220/380V±10% or customized 50/60Hz±2Hz
Brand Name GENY
Model Number YCS-103
Certification ISO, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/P, T/T Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks Packaging Details Plywood cases
Test voltage output 3×(24V – 288V) or customized Power of the voltage output 3×100VA/3×250VA/3×500VA/3×1000VA
Test current output 3×(1mA – 100A) Phase angle range 0 -- 360°
Relative humidity 35% -- 85% Ambient temperature -10°C -- +40°C
Voltage Supply 3×220/380V±10% or customized 50/60Hz±2Hz Brand Name GENY
Model Number YCS-103 Certification ISO, CE
Place of Origin China
High Light High-Precision Harmonic Power EquipmentYCS-103/101 Harmonic Power EquipmentHarmonic Power Equipment

YCS-103/101 Series High-Precision Harmonic Power Equipment OEM/ODM Services

Description:

YCS—103

  • Constructed from aluminum alloy materials, this device boasts a combination of lightweight properties and robustness, effectively preventing corrosion while ensuring high accuracy and stability in output.
  • Equipped with an optional keyboard, facilitating manual operation as needed.
  • Capable of outputting from the 2nd to the 21st harmonic, with programmable amplitudes and degrees.
  • Easily operable via PC control software suite, streamlining operation processes.
  • Features an RS232 interface, enabling automatic operation and integration with external systems.
  • Incorporates protective measures against overload, short voltage circuits, and open current circuits, ensuring safety and reliability during operation.

YCS-101

  • High accuracy and high stability source output
  • With RS232 interface for automatic operation
  • With keyboard for manual operation (optional).
  • 2nd – 21st harmonic, output amplitude and degree can be programmed.
  • Aluminum alloy materials, light and strong, prevent corrosion.
  • With the protect function of overload, short voltage circuit and open current circuit.
  • PC control software suit, easy operation and support secondary software development

 

Technical Specifications:

 

ParameterYCS-103-250YCS-103-600YCS-103-1200YCS-103-2500
Voltage    
Test Voltage Output (Phase-Neutral)3×(24V – 288V) or customized3×(24V – 288V) or customized3×(24V – 288V) or customized3×(24V – 288V) or customized
Power of the Voltage Output3×100VA3×250VA3×500VA3×1000VA
ResolutionBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of range
Setting AccuracyBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load< 0.01%< 0.01%< 0.01%< 0.01%
Distortion Factor< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load
Harmonics (2nd – 21st)Free programmableFree programmableFree programmableFree programmable
Current    
Test Current Output3×(1mA – 100A)3×(1mA – 100A)3×(1mA – 100A)3×(1mA – 100A)
Power of the Current Output3×150VA3×350VA3×750VA3×1500VA
ResolutionBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of rangeBetter than 0.01% of full scale value of range
Setting AccuracyBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range valueBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)Better than 0.005%/h (integration time 150 s)
Load Regulation from 0-max. Load< 0.01%< 0.01%< 0.01%< 0.01%
Distortion Factor< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load< 0.3% for linear resistance load
Harmonics (2nd – 21st)Free programmableFree programmableFree programmableFree programmable
Phase Angle    
Range0 -- 360°0 -- 360°0 -- 360°0 -- 360°
Resolution0.01°0.01°0.01°0.01°
Setting Accuracy0.1°0.1°0.1°0.1°
Frequency    
Range45Hz – 65Hz45Hz – 65Hz45Hz – 65Hz45Hz – 65Hz
Resolution0.01Hz0.01Hz0.01Hz0.01Hz
Voltage Supply    
Voltage Supply3×220/380V±10% or customized3×220/380V±10% or customized3×220/380V±10% or customized3×220/380V±10% or customized
Frequency50/60Hz±2Hz50/60Hz±2Hz50/60Hz±2Hz50/60Hz±2Hz
Operating Conditions    
Ambient Temperature-10°C -- +40°C-10°C -- +40°C-10°C -- +40°C-10°C -- +40°C
Relative Humidity35-- 85%35% -- 85%35% -- 85%35% -- 85%

 

 YCS-101-250YCS-101-600YCS-101-1200YCS-101-2500
Voltage Source
Test voltage output (Phase-Neutral)24V – 288V or customized
Power of the voltage output100VA250VA500VA1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Current Source
Test current output1mA – 100A
Power of the current output150VA350VA750VA1500VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Phase angle
Range0 -- 360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45Hz – 65Hz
Resolution0.01Hz
 
Voltage Supply220V±10% or 50/60Hz±2Hz or customized
Ambient temperature-10°C -- +40°C
Relative humidity35% -- 90%

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement