Payment Terms | T/T, L/C, D/P, T/T |
Supply Ability | 5 sets / 1 months |
Delivery Time | 6~8weeks |
Packaging Details | Plywood cases |
Test voltage output | 3×(24V – 288V) or customized |
Power of the voltage output | 3×100VA/3×250VA/3×500VA/3×1000VA |
Test current output | 3×(1mA – 100A) |
Phase angle range | 0 -- 360° |
Relative humidity | 35% -- 85% |
Ambient temperature | -10°C -- +40°C |
Voltage Supply | 3×220/380V±10% or customized 50/60Hz±2Hz |
Brand Name | GENY |
Model Number | YCS-103 |
Certification | ISO, CE |
Place of Origin | China |
View Detail Information
Explore similar products
Stationary Power Source Three Phase Power Systems GENY YCSS-103
Electronic Meter 3 Phase Power Source Variable Frequency Customized
Stationary Single Phase Power Source Electric Equipment YCS-101-250
Customized YCS-103-250 Three Phase Power Source with Direct Connected Installati
Product Specification
Payment Terms | T/T, L/C, D/P, T/T | Supply Ability | 5 sets / 1 months |
Delivery Time | 6~8weeks | Packaging Details | Plywood cases |
Test voltage output | 3×(24V – 288V) or customized | Power of the voltage output | 3×100VA/3×250VA/3×500VA/3×1000VA |
Test current output | 3×(1mA – 100A) | Phase angle range | 0 -- 360° |
Relative humidity | 35% -- 85% | Ambient temperature | -10°C -- +40°C |
Voltage Supply | 3×220/380V±10% or customized 50/60Hz±2Hz | Brand Name | GENY |
Model Number | YCS-103 | Certification | ISO, CE |
Place of Origin | China | ||
High Light | High-Precision Harmonic Power Equipment ,YCS-103/101 Harmonic Power Equipment ,Harmonic Power Equipment |
YCS—103
YCS-101
Parameter | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Voltage | ||||
Test Voltage Output (Phase-Neutral) | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized | 3×(24V – 288V) or customized |
Power of the Voltage Output | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Current | ||||
Test Current Output | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) | 3×(1mA – 100A) |
Power of the Current Output | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range | Better than 0.01% of full scale value of range |
Setting Accuracy | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) | Better than 0.005%/h (integration time 150 s) |
Load Regulation from 0-max. Load | < 0.01% | < 0.01% | < 0.01% | < 0.01% |
Distortion Factor | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load | < 0.3% for linear resistance load |
Harmonics (2nd – 21st) | Free programmable | Free programmable | Free programmable | Free programmable |
Phase Angle | ||||
Range | 0 -- 360° | 0 -- 360° | 0 -- 360° | 0 -- 360° |
Resolution | 0.01° | 0.01° | 0.01° | 0.01° |
Setting Accuracy | 0.1° | 0.1° | 0.1° | 0.1° |
Frequency | ||||
Range | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz | 45Hz – 65Hz |
Resolution | 0.01Hz | 0.01Hz | 0.01Hz | 0.01Hz |
Voltage Supply | ||||
Voltage Supply | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized | 3×220/380V±10% or customized |
Frequency | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz | 50/60Hz±2Hz |
Operating Conditions | ||||
Ambient Temperature | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C | -10°C -- +40°C |
Relative Humidity | 35-- 85% | 35% -- 85% | 35% -- 85% | 35% -- 85% |
YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 | |
Voltage Source | ||||
Test voltage output (Phase-Neutral) | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current Source | ||||
Test current output | 1mA – 100A | |||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 220V±10% or 50/60Hz±2Hz or customized | |||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 90% |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!