Payment Terms | L/C,T/T,D/P |
Supply Ability | 50/Year |
Model NO. | YC99T-3C/5C |
Meter Position / Accuracy | 3 / 0.05 |
Brand Name | GENY |
Model Number | YC99T |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Portable Meter Test System For AC Voltage Current Power Phase And Frequency
Portable Meter Test System with High Accuracy Current and Voltage Source
Portable Meter Test System For Three Phase Energy Meters With Automatic
0.05 Accuracy Portable Meter Test Equipment Three Phase Test Meter Calibration
Product Specification
Payment Terms | L/C,T/T,D/P | Supply Ability | 50/Year |
Model NO. | YC99T-3C/5C | Meter Position / Accuracy | 3 / 0.05 |
Brand Name | GENY | Model Number | YC99T |
Certification | ISO, CE | Place of Origin | CHINA |
The product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. Additionally, it is utilised by manufacturers of energy meters, encompassing their production, research and development, and testing departments, as well as in academic institutions and associated research bodies.
This product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. It is also used by manufacturers of energy meters, including their production, research and development, and testing departments, as well as in universities and related research institutions, and specialised laboratories.
The meters user can calibrate the following meters: single-phase active energy meter, three-phase three-wire active energy meter, three-phase three-wire composite meter, three-phase four-wire active energy meter, three-phase four-wire composite meter, three-phase three-wire sine reactive energy meter, three-phase four-wire sine reactive energy meter, two elements 60° reactive energy meter, two elements 90° reactive energy meter, and three elements 90° reactive energy meter.
Model No. | YC99T-3C |
Meter Position / Accuracy | 3 / 0.05 |
AC Voltage output | |
Range | 57.7V,100V, 220V, 380V 660 |
Adjustment Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 20VA/phase |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
AC Current output | |
Range | 0.05A 0.2A 1A 5A 16.67A 50A |
Adjust Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 50VA(50A range) |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
Power output | |
Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) |
Active, Reactive power accuracy | %0.05%RG |
Phase output | |
Output adjusting range | 0 ~ 359.99 |
Output adjusting power | 10°,1°,0.1°,0.01°optional |
Resolution | 0.01 |
Measurement accuracy | %0.05 |
Power factor output | |
Adjusting range | -1~0~+1 |
Measuring resolution | 0.0001 |
Measurement accuracy | %0.0005 |
Frequency output | |
Adjusting range | 40Hz – 70Hz |
Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional |
Resolution | 0.001Hz |
Accuracy | %0.002Hz |
Harmonic setting | |
Harmonic order | 2nd~63rd |
Harmonic amplitude | 0~40% |
Harmonic angle | 0 ~359.00 |
Harmonic set error | 2nd ~ 31st : %0.1%, 32nd~63rd: %0.2% |
Energy error measurement | |
Active energy basic error limit | %0.05%RD(voltage30V~660V,current0.02A~60A,PF 0.5) |
Reactive energy basic error limit | %0.1%RD(voltage30V~660V,current0.02A~60A,PF 0.5) |
Standard crystal | |
Frequency accuracy | %0.5ppm (leave factory@25 ) |
Frequency stability | %0.1ppm,-20 ~+70 |
Energy pulse input | |
Number of energy pulse input | 3 channels active, 3 channels reactive |
General parameters | |
Power supply | AC220V%15% or 110V%15% |
Frequency | 50Hz~60Hz |
Consumption | 60VA~1000VA |
Environment condition | 20 ~ 30 relative humidity |
Storage environment | -20 ~50 |
Size & Weight | 600mm(L) 400mm(W) 266mm(H), 30kg |
Model No. | YC99T-5C |
Meter Position / Accuracy | 3 / 0.05cl |
AC Voltage output | |
Range | 57.7V,100V, 220V, 380V |
Adjustment Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (resistance load) |
Max Output load | 20VA/phase |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
AC Current output | |
Range | 0.05A 0.2A 1A 5A 20A 100A |
Adjust Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG(optional) |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 100VA(100A range) |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
Power output | |
Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) |
Active, Reactive power accuracy | %0.05%RG |
Phase output | |
Output adjusting range | 0 ~ 359.99 |
Output adjusting power | 10°,1°,0.1°,0.01°optional |
Resolution | 0.01 |
Measurement accuracy | %0.05 |
Power factor output | |
Adjusting range | -1~0~+1 |
Measuring resolution | 0.0001 |
Measurement accuracy | %0.0005 |
Frequency output | |
Adjusting range | 45Hz – 70Hz |
Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz |
Resolution | 0.001Hz |
Accuracy | %0.002Hz |
Harmonic setting | |
Harmonic order | 2nd~63rd |
Harmonic amplitude | 0~40% |
Harmonic angle | 0 ~359.99 |
Harmonic set error | 2nd ~ 31st : %0.1%, 32nd~63rd: %0.2% |
Energy error measurement | |
Active energy basic error limit | %0.05%RD(voltage30V~380V,current0.02A~120A,PF 0.5) |
Reactive energy basic error limit | %0.1%RD(voltage30V~380V,current0.02A~120A,PF 0.5) |
Standard crystal | |
Frequency accuracy | %0.5ppm (leave factory@25 ) |
Frequency stability | %0.1ppm,-20 ~+70 |
Energy pulse input | |
Number of energy pulse input | 3 channels active, 3 channels reactive |
General parameters | |
Power supply | AC220V%15% or 110V%15% |
Frequency | 50Hz~60Hz |
Consumption | 60VA~1000VA |
Environment condition | 20 ~ 30 relative humidity |
Storage environment | -20 ~50 |
Size & Weight | 600mm(L) 400mm(W) 266mm(H), 48kg |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!