China factories

China factory - Silian Technical Import & Export Co.,ltd.chongqing

Silian Technical Import & Export Co.,ltd.chongqing

  • China,Chongqing ,Chongqing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor
China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor

  1. China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor
  2. China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor
  3. China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor
  4. China DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor

DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor

  1. MOQ: 1 SET
  2. Price: Negotiated Pricing
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T
Supply Ability As Appropriate
Delivery Time As Appropriate
Packaging Details Strong Export Packing
Product Name MF Electromagnetic Flowmeter
Model MF
Product Features Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage)
Diameter (mm DN2.5-DN2400
Communication protocol PROFIBUS bus / FF bus / HART bus / MODBUS bus
Explosion proof grade Exia/deⅡCT4-T6 Ga/Gb
Basic error ±0.2% or ±0.5% of the indicating value
Protection level IP65/IP67 (sensor IP68 optional)
Ambient temperature -40°C~65°C
Power supply ACAC(100-230) ±1 5%V, 47Hz-440Hz, maximum power consumption is 20VA; DC 11V-40V, maximum power consumption is 20VA, and power consumption of two-wire system is 0.5VA
Functional type two-wire system/slurry system/sanitary system/quick response system/plug-in system/battery-powered system/nuclear power system
Brand Name CHONGQING CHUANYI, SICC
Model Number MF
Certification IECEX certification, CE certification, CU-TR(ERC) certification, CCS certification ,ISO9001, ISO14000, ISO45001
Place of Origin CHONGQING,CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T Supply Ability As Appropriate
Delivery Time As Appropriate Packaging Details Strong Export Packing
Product Name MF Electromagnetic Flowmeter Model MF
Product Features Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage) Diameter (mm DN2.5-DN2400
Communication protocol PROFIBUS bus / FF bus / HART bus / MODBUS bus Explosion proof grade Exia/deⅡCT4-T6 Ga/Gb
Basic error ±0.2% or ±0.5% of the indicating value Protection level IP65/IP67 (sensor IP68 optional)
Ambient temperature -40°C~65°C Power supply ACAC(100-230) ±1 5%V, 47Hz-440Hz, maximum power consumption is 20VA; DC 11V-40V, maximum power consumption is 20VA, and power consumption of two-wire system is 0.5VA
Functional type two-wire system/slurry system/sanitary system/quick response system/plug-in system/battery-powered system/nuclear power system Brand Name CHONGQING CHUANYI, SICC
Model Number MF Certification IECEX certification, CE certification, CU-TR(ERC) certification, CCS certification ,ISO9001, ISO14000, ISO45001
Place of Origin CHONGQING,CHINA
High Light DSP IP67 Electromagnetic Flow MetersIP67 DSP Water Electromagnetic Flow MetersIP67 DSP Water Pipe Flow Sensor

ADVANCED SENSOR PIPE SECTION MULTIPHASE FLOW CONE SEAL MF ELECTROMAGNETIC FLOWMETER

  • The flow measurement range is wide, and the range ratio is 1500:1.
  • The flow rate of minimum guaranteed accuracy is 0.2m/s.
  • Advanced sensor technology can ensure that the installation of straight pipe section takes only 1.6D.
  • High accuracy: up to 0.2% indicating value
  • Forward and backward flow are measurable: pulse flow, multiphase flow and slurry are measurable.
  • The input of the converter is more than 1012 ohms, which can effectively prevent the influence of scaling on the sensor, and the minimum conductivity can reach 1.7us/cm.
  • The electrode seal adopts a unique double-sided sealing method of cone seal and line seal.
  • Buried installation and long-term immersion installation are allowable, up to IP68.
  • Multi-frequency excitation technology/DSP digital processing technology/high frequency sampling technology/data coordinating analysis technology
  • Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage)

 

Main Technical Parameters:

 

Flow Master

MFE-S type

High protection

electromagnetic flowmeter

     
split type

One type

(IP67)

Explosion proof integrated type
Basic error ± 0.2% or ± 0.5% of the indicated value  
caliber (mm) DN2.5~DN2400 DN2.5~DN2400
Explosion proof grade ------------ Exia/de Ⅱ CT4 Ga/Gb
flange Comply with gb9119 standard, carbon steel (optional stainless steel)
Pressure class

DN2.5~DN600 1.0 1.6 2.5 4.0MPa

DN700~DN2400 0.6MPa

The special pressure shall be determined through consultation with the company

DN2.5~DN600 1.0 1.6 2.5 4.0MPa

The special pressure shall be determined through consultation with the company

Lining material PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46, natural rubber, neoprene, ETFE
conductivity ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our company )
electrode 316L, Hastelloy, titanium, tantalum, platinum iridium alloy, tungsten carbide
Degree of protection IP67(Sensor optional IP68) IP67
Medium temperature

-25℃~140℃

See lining material selection for details

-25℃~80℃

See lining material selection for details

ambient temperature -25℃~60℃
Influence of ambient temperature <±0.1%/10℃or<±0.25%/10℃
Repeatability and repeatability ≤±0.1%or±0.25%
Analog output error ≤±0.02mA
Measuring range flow rate ≤20m/s
Embedability ≤5m(Only IP68) -----------
Sensor cable

<100m

If it is too long, you need to negotiate with our company to order

-----------
Electrical connection M20*1.5Sealing sleeve,G1/2,NPT1/2
Output interface* Standard output (pulse + 4 ~ 20mA single current output), dual current output, RS485,HART,Profibus-PA

Note*: 4-20mA analog output is active output

 

Product performance

·The simple measured current output is used to display the flow, and the pulse output is used to drive the external accumulator or as the status output

·Can ensure the reliability, safety and stability of measured values of all basic functions

·The optimized process control accuracy is + 0.5%

·PTFE lining ensures maximum corrosion resistance and temperature resistance up to 130 ℃

·It can be assembled under most difficult conditions (such as shaft, vibration or long-term underwater). The sensor can be installed independently without sensor, and the protection level is IP68

·The functional design makes maintenance simple and easy. Hart, fieldtool and fieldcheck provide support for equipment verification, so there is no need to move the sensor

 

 

Application Scenarios:

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Importer,Exporter,Trading Company,Seller

  • Year Established:

    1965

  • Total Annual:

    1450000000-1550000000

  • Employee Number:

    5000~6000

  • Ecer Certification:

    Active Member

Silian Technical Import & Export Co. Ltd.Chongqing (STIEC). STIEC is the full invested corporation of Chongqing Chuanyi Automation Co. Ltd. (SIC) which belongs to China Silian Instrument Group Co. Ltd. (SIC Group). STIEC basing upon the products of SIC and SIC Group as its supply source... Silian Technical Import & Export Co. Ltd.Chongqing (STIEC). STIEC is the full invested corporation of Chongqing Chuanyi Automation Co. Ltd. (SIC) which belongs to China Silian Instrument Group Co. Ltd. (SIC Group). STIEC basing upon the products of SIC and SIC Group as its supply source...

+ Read More

Get in touch with us

  • Reach Us
  • Silian Technical Import & Export Co.,ltd.chongqing
  • 6F,TECHNOLOGY BUILDING,CHUANYI INDUSTRIAL PARK,61 HUANGSHAN AVE,LIANGJIANG NEW AREA,CHONGQING 401121,CHINA.
  • https://www.meter-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement