Payment Terms | L/C, D/A, D/P, T/T |
Supply Ability | As Appropriate |
Delivery Time | As Appropriate |
Packaging Details | Strong Export Packing |
Product Name | MF Electromagnetic Flowmeter |
Model | MF |
Product Features | Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage) |
Diameter (mm | DN2.5-DN2400 |
Communication protocol | PROFIBUS bus / FF bus / HART bus / MODBUS bus |
Explosion proof grade | Exia/deⅡCT4-T6 Ga/Gb |
Basic error | ±0.2% or ±0.5% of the indicating value |
Protection level | IP65/IP67 (sensor IP68 optional) |
Ambient temperature | -40°C~65°C |
Power supply | ACAC(100-230) ±1 5%V, 47Hz-440Hz, maximum power consumption is 20VA; DC 11V-40V, maximum power consumption is 20VA, and power consumption of two-wire system is 0.5VA |
Functional type | two-wire system/slurry system/sanitary system/quick response system/plug-in system/battery-powered system/nuclear power system |
Brand Name | CHONGQING CHUANYI, SICC |
Model Number | MF |
Certification | IECEX certification, CE certification, CU-TR(ERC) certification, CCS certification ,ISO9001, ISO14000, ISO45001 |
Place of Origin | CHONGQING,CHINA |
View Detail Information
Explore similar products
Mpm Multiphase Electromagnetic Flow Meters Wide Range Accuracy 0.2m/S
SICC Cone Seal Inline Electromagnetic Flow Meters 0.2 High Accuracy
Flameproof Electromagnetic Water Flow Meter For Sewage Water PTFE Lining
Self Diagnosis IP67 Electromagnetic Flow Meters DN2.5-DN2400
Product Specification
Payment Terms | L/C, D/A, D/P, T/T | Supply Ability | As Appropriate |
Delivery Time | As Appropriate | Packaging Details | Strong Export Packing |
Product Name | MF Electromagnetic Flowmeter | Model | MF |
Product Features | Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage) | Diameter (mm | DN2.5-DN2400 |
Communication protocol | PROFIBUS bus / FF bus / HART bus / MODBUS bus | Explosion proof grade | Exia/deⅡCT4-T6 Ga/Gb |
Basic error | ±0.2% or ±0.5% of the indicating value | Protection level | IP65/IP67 (sensor IP68 optional) |
Ambient temperature | -40°C~65°C | Power supply | ACAC(100-230) ±1 5%V, 47Hz-440Hz, maximum power consumption is 20VA; DC 11V-40V, maximum power consumption is 20VA, and power consumption of two-wire system is 0.5VA |
Functional type | two-wire system/slurry system/sanitary system/quick response system/plug-in system/battery-powered system/nuclear power system | Brand Name | CHONGQING CHUANYI, SICC |
Model Number | MF | Certification | IECEX certification, CE certification, CU-TR(ERC) certification, CCS certification ,ISO9001, ISO14000, ISO45001 |
Place of Origin | CHONGQING,CHINA | ||
High Light | DN2400 Multi Phase Flow Meter ,DN2.5 Multi Phase Flow Meter ,Exproof electromagnetic water meter DN2400 |
ADVANCED SENSOR PIPE SECTION MULTIPHASE FLOW CONE SEAL MF ELECTROMAGNETIC FLOWMETER
Main Ttechnical Pparameters:
Flow Master MFE-S type electromagnetic flowmeter | ||
One type | split type | |
Basic error | ± 0.2% or ± 0.5% of the indicated value | |
caliber (mm) | DN2.5~DN2400 | DN2.5~DN2400 |
flange | Comply with gb9119 standard, carbon steel (optional stainless steel) | |
Pressure class | DN2.5~DN600 1.0 1.6 2.5 4.0MPa DN700~DN2400 0.6MPa The special pressure shall be determined through consultation with the company | |
Lining material | PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46, natural rubber, neoprene, ETFE | |
conductivity | ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our company ) | |
electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy, tungsten carbide | |
Degree of protection | IP65 | IP65(Sensor optional IP68) |
Medium temperature | -25℃~80℃ See lining material selection for details | -25℃~140℃ See lining material selection for details |
ambient temperature | -25℃~60℃ | |
Influence of ambient temperature | <±0.1%/10℃or<±0.25%/10℃ | |
Repeatability and repeatability | ≤±0.1%or±0.25% | |
Analog output error | ≤±0.02mA | |
Measuring range flow rate | ≤20m/s | |
Embedability | ------------ | ≤5m(Only IP68) |
Electrical connection | M20*1.5Sealing sleeve,G1/2,NPT1/2 | |
Sensing cable | ------------ | If it is too long, you need to negotiate with our company to order |
Output interface* | Standard output (pulse + 4 ~ 20mA single current output), dual current output, RS485,HART,Profibus-PA |
Note*: 4-20mA analog output is active output
Application Scenarios:
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Trading Company,Seller
Year Established:
1965
Total Annual:
1450000000-1550000000
Employee Number:
5000~6000
Ecer Certification:
Active Member
Silian Technical Import & Export Co. Ltd.Chongqing (STIEC). STIEC is the full invested corporation of Chongqing Chuanyi Automation Co. Ltd. (SIC) which belongs to China Silian Instrument Group Co. Ltd. (SIC Group). STIEC basing upon the products of SIC and SIC Group as its supply source... Silian Technical Import & Export Co. Ltd.Chongqing (STIEC). STIEC is the full invested corporation of Chongqing Chuanyi Automation Co. Ltd. (SIC) which belongs to China Silian Instrument Group Co. Ltd. (SIC Group). STIEC basing upon the products of SIC and SIC Group as its supply source...
Get in touch with us
Leave a Message, we will call you back quickly!