Payment Terms | L/C, T/T, Western Union |
Supply Ability | 100 |
Delivery Time | Shipping Date: July 1-31, 2022 |
Packaging Details | Dimensions (L*W*H) (mm) 6058*2438*2896 |
Brand Name | ANTSPACE |
Model Number | ANTSPACE HK3 |
View Detail Information
Explore similar products
ANTMINER S19 PRO+ HYDRO Bitmain Antspace BCH BSV Cryptocurrency
Bitmain Antminer Antspace HK3 BTC MINER CONTAINER
T19 Hydro 145TH S19 Hydro 158TH Bitmain Antspace 5438 Watt SHA256
Antminer T19 Hydro 145Th From Bitmain Mines Bitcoin SHA256 Algorithm
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 100 |
Delivery Time | Shipping Date: July 1-31, 2022 | Packaging Details | Dimensions (L*W*H) (mm) 6058*2438*2896 |
Brand Name | ANTSPACE | Model Number | ANTSPACE HK3 |
High Light | HK3 Crypto meta miner tech ,HK3 meta miner tech ,S19 Hydro meta miner tech |
customized ANTSPACE HK3 (with DWT-T/DWT-C) Mining farm for S19 hydro
Specification Details For ANTSPACE HK3
Product Overview |
|
Version | ANTSPACE HK3 |
Dimensions (L*W*H) (mm) | 6058*2438*2896 |
Miner Capacity | 210 units -S19 Hyd. Series miner |
Container Certification | China Classification Society Certification |
Safety Certification | North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, |
Operating Power(kW) | 1047~1050 |
PUE(Power Usage Effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) |
Input Voltage and Frequency | 415V±5% 60Hz(North America) |
Detailed Characteristics |
|
Shipping Weight(T) | 8 |
Operating Weight (T) | 12 |
Main Switch of Power Distribution Cabinets(A) | 1200(North America) |
Rated Current(A) | 952 |
Standard Power(kW) | 1049 |
Maximum Power(kW) | 1050 |
Rated Current per Miner(A) | 10 |
Inlet Cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: |
Connection Interface(Cooling Tower) | DN125(GB/T 9119-2010 PN16 DN125) |
Connection Interface(Plate Heat Exchage Interface) | DN100(GB/T 9119-2010 PN16 DN100) |
Flow Rate(m³/h) | >85 |
Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 |
Specification Details For Dry-Wet Towers
One of the following two Dry-Wet Towers can be chosen based on the personalized demand.
Product Overview |
| |
Type | Dry-Wet Tower Traditional Type (DWT-T) | Dry-Wet Tower Container Type (DWT-C) |
Dimensions(L*W*H)(mm) | 5800*2240*4200 | 6058*2438*2896 |
Heat Dissipation Capacity(kW) | 1000 | 1000 |
Outlet Temperature @ 28℃ Wet Bulb Temperature | 35℃ | 35℃ |
Container Certification | None | China Classification Society Certification |
Safety Certification | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, |
Operating Power(kW) | 14~28 | 14~28 |
Motor Rated Voltage and Frequency | 415V±5% 60Hz(North America) | 415V±5% 60Hz(North America) |
Detailed Characteristics |
| |
Shipping Weight(T) | 5 | 6 |
Operating Weight(T) | 9 | 10 |
Connection Interface(Container) | DN125(GB/T 9119-2010 PN16 DN125) | DN125(GB/T 9119-2010 PN16 DN125) |
Water Resupply Pipe Interface | DN40(Internal thread) | DN40(Internal thread) |
Drain Pipe Interface | DN65(Internal thread) | DN65(Internal thread) |
Noise Level @25℃, 16m | 70dBA | 70dBA |
Water Consumption(m³/h) | 1~1.5 | 1~1.5 |
| Environmental Requirementss
Environmental Requirements | |
1 | Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree). |
2 | The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load. |
3 | A 10-ton crane is needed for unloading ANTSPACE and cooling tower. |
4 | Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed. |
5 | Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult. |
6 | Keep at least 2 meters of air in-take space around the cooling tower. |
7 | Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters. |
8 | Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine. |
9 | When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode. |
10 | Choose pure water or suitable antifreeze as coolant based on local climate conditions. |
11 | The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine. |
| Purchasing Guidelines
NOTES
1. The ANTSPACE HK3 is recommended to be used simultaneously with The ANTMINER S19 Pro+ Hyd. Please click here for more details on S19 Pro+ Hyd.
2. The pictures shown are for reference only; the final shipment version shall prevail.
Company Details
Business Type:
Trading Company
Year Established:
2017
Employee Number:
20~60
Ecer Certification:
Active Member
We were established in 2017. We are committed to providing the latest and various cryptocurrency mining equipment. Our goal is to provide our global customers with the highest quality international products. We were established in 2017. We are committed to providing the latest and various cryptocurrency mining equipment. Our goal is to provide our global customers with the highest quality international products.
Get in touch with us
Leave a Message, we will call you back quickly!