Payment Terms | T/T or Western Union |
Supply Ability | 10,000pcs per month |
Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit. |
Packaging Details | Packed in bubble bag firstly, and then reinforced with carton for outer packing |
Rated Input Voltage | 220-240Vac 50Hz /60Hz |
Emergency power | 3W(Can be customized) |
Emergency Time | 180min (Can be customized) |
Warranty | 3 Years |
Load output voltage | 80-200Vdc |
Working temprature | 0℃~50℃ |
IP Rating | IP20 |
Battery type | LifePO4 |
Brand Name | Kreatpower |
Model Number | KE007-03A180HE2 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
3W 3HOURS LED Emergency Pack With External LifePO4 Battery For 3 Years Warranty
3.7V 2600mAh manual test constant Power 3W Emergency Drivers with built-in
LifePO4 6.4V 1800mAh built-in battery electronic led converter for LED panel or
LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002
Product Specification
Payment Terms | T/T or Western Union | Supply Ability | 10,000pcs per month |
Delivery Time | 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit. | Packaging Details | Packed in bubble bag firstly, and then reinforced with carton for outer packing |
Rated Input Voltage | 220-240Vac 50Hz /60Hz | Emergency power | 3W(Can be customized) |
Emergency Time | 180min (Can be customized) | Warranty | 3 Years |
Load output voltage | 80-200Vdc | Working temprature | 0℃~50℃ |
IP Rating | IP20 | Battery type | LifePO4 |
Brand Name | Kreatpower | Model Number | KE007-03A180HE2 |
Certification | CE | Place of Origin | China |
High Light | 1800mAh auto-test emergency packs ,constant Power auto-test emergency packs ,6.4V auto-test emergency packs |
6.4V 1800mAh constant Power 3W auto-test emergency packs with battery lifepo4 and 3 years warranty
1. Description
1) Constant power output LED emergency power supply with a wide output voltage range;
2) Input; output relay switching.
3) High safety, high performance, long life LifePO4 battery.
4) With multiple protection functions: battery overcharge, over-discharge protection, and output short circuit protection.
2. Parameters
Charge Part | KE007 | 02M180HE | 03M180HE | 04M180HE | 05M180HE | |
02A180HE | 03A180HE | 04A180HE | 05A180HE | |||
Rated input voltage | 220-240Vac 50Hz /60Hz | |||||
Rated input current | 0.06A Max. @230Vac | |||||
Input inrush current | 30A(twidth=100uS 50% Ipeak )@230Vac(Cold start at full load ) | |||||
Power factor | ≥0.5@230Vac | |||||
Input power | <4W | |||||
Battery charging current | 200mA | 200mA | 350mA | 350mA | ||
Battery charging time | 24 hours Max | |||||
Emergency Part | Operating mode | Emergency mode | ||||
Load type | LED | |||||
Emergency power | 2W | 2.5W | 4W | 5W | ||
Emergency time | 3hours | |||||
Load output current | 25-10mA | 30-12mA | 45-20mA | 57-23mA | ||
Load output voltage | 80-200VDC | |||||
Battery | LifePO4 (The battery capacity meets the emergency time at 25℃) | 6.4V 1.6Ah | 6.4V 1.6Ah | 6.4V 3.6Ah | 6.4V 3.6Ah | |
Battery warranty | Warranty 3 years, Design Life 5 years. | |||||
Exception Driver Requirements | Surge current | 8A | ||||
Input current | 3 A Max. | |||||
Output current | N/A | |||||
LED Indication (Manual test) | Charging | Greenlight | ||||
Fault | Green light off | |||||
Emergency Function Test | Manual test | Yes | ||||
Autotest | 02A180HE/03A180HE/04A180HE/05A180HE | |||||
Auto Testing | Fault/test / Status | Reason | Charge Indicator Status | |||
Battery fully charged and operational | Standard daily use | solid green | ||||
solid green | ||||||
Battery Charging | Initial Charge/Battery Top Up | solid green | ||||
solid green | ||||||
Auto Test 3 Hours (every 12 months) | Periodic self-test | Flashing Green 3 sec on 1 sec off | ||||
Flashing Green 3 sec on 1 sec off | ||||||
Auto Test 5 Min (every 30 days) | Periodic self-test | Flashing Green 3 sec on 3 sec off | ||||
Flashing Green 3 sec on 3 sec off | ||||||
Duration test fault | Failed the 3-hour annual test | Flashing Red 0.5 sec on 0.5 sec off | ||||
Flashing Red 0.5 sec on 0.5 sec off | ||||||
LED fault | Not plugged in or damaged/faulty | Flashing Red 2 sec on – 2 sec off | ||||
Flashing Red 2 sec on – 2 sec off | ||||||
Battery Disconnected/Faulty | Not plugged in or damaged/faulty | solid red | ||||
solid red | ||||||
Emergency protection | Battery over-charge/deep discharge protection | Yes | ||||
Output over-voltage protection | Yes | |||||
Output overload protection | Yes | |||||
Output short circuit protection | Yes | |||||
Operating Environment | Operating temperature/humidity | 0℃…+50℃; Humidity:20%-75%(without condensation) | ||||
Storage temperature/humidity | -5℃-35℃ | |||||
Case Max. Temp(Tc) | 75℃ | |||||
Safety & EMC
| Withstand voltage | NO ISO | ||||
Safety standard | EN61347-1, EN61347-2-7 | |||||
EMC standard | EN55015, EN61000-3-2, EN61000-3-3 | |||||
Battery standard | UN38.3 | |||||
Environmental protection requirements | Compliant to RoHS | |||||
Certification | CE | |||||
Others | Input/output(terminal/wiring) specification | Press terminal, wire diameter:0.5-0.75mm2 | ||||
IP rating | IP20 | |||||
Type of protection | Class 2 | |||||
Installation type | Built-in installation | |||||
Installation dimension | 146*30*22.5mm | |||||
Packaging requirement | White box+Instruction manual+clapboard+outer carton(K=A) | |||||
Others | Weight | 85g(driver) | ||||
Lifespan | 5 Year @Ta ( Battery not included ) | |||||
Notes: All parameters are tested on the input voltage 230Vac, environment temperature 25℃ unless otherwise specified. |
3. Dimension (Unit:mm)
4. Wiring Diagram
5. Function
6 . Manual Test & Operation Instructions
1). Connect the wire according to the wiring diagram.
2). L, N power on, Switch on S1. then the load lamp turns on, The emergency driver indicator light turns green, emergency power supply normally charging. Turn off Switch S1, and the load lamp turns off.
3). Emergency Simulation: Switch on, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, and the indicator light of the emergency driver will be extinguished. Release the switch(TEST SWITCH), then the lamp is powered by the led driver, the indicator light will turn on.
7. Battery Application Notice
1)The battery should be recharged and discharged semiannually in normal use conditions.
2)Do not connect to the circuit when the battery is not used to prevent over-discharge of the battery due to self-consumption of the circuit board.
3)Please keep the battery from the heat source when installing and using it, and only be allowed to use it in a certain working temperature range.
4)The battery should be stored in a cool and dry environment.
5)After a long time of storage, the battery is cycled every 12 months as required.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Focus on intelligent lighting control and innovate constantly! About Merrytek Shenzhen Merrytek Technology Co. Ltd, founded in 2011 in Shenzhen China. For more than 13 years, we have been dedicated to research electronical products for professional lighting & smart co... Focus on intelligent lighting control and innovate constantly! About Merrytek Shenzhen Merrytek Technology Co. Ltd, founded in 2011 in Shenzhen China. For more than 13 years, we have been dedicated to research electronical products for professional lighting & smart co...
Get in touch with us
Leave a Message, we will call you back quickly!