Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Packaging Details | Wooden case |
Type | Blood Testing Equipments |
Name | BSC Biosafety Cabinet |
Overall size | 1800×800×2120mm |
Purification area size | 1600×700×600mm |
Product name | Biosafety cabinet |
Model | BSC-1600B2 |
Downflow velocity | 0.31±0.025m/s |
Inflow velocity | 0.48±0.025m/s |
Brand Name | HAIYING |
Model Number | BSC-1600B2 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Hospital College Laboratory BSC Biosafety Cabinet LCD Display
ISO 5 Class II BSC Biological Safety Cabinet CE HEPA
100 Level Protection BSC Biosafety Cabinet UV Sterilization
Laminar Ductless Bsl 2 Biosafety Cabinet Class 2 Thermo Scientific
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Packaging Details | Wooden case |
Type | Blood Testing Equipments | Name | BSC Biosafety Cabinet |
Overall size | 1800×800×2120mm | Purification area size | 1600×700×600mm |
Product name | Biosafety cabinet | Model | BSC-1600B2 |
Downflow velocity | 0.31±0.025m/s | Inflow velocity | 0.48±0.025m/s |
Brand Name | HAIYING | Model Number | BSC-1600B2 |
Certification | CE | Place of Origin | CHINA |
High Light | experiments BSC Biosafety Cabinet ,Centrifugal BSC Biosafety Cabinet ,Centrifugal biological safety cabinet class 2 |
BSC Biosafety Cabinet Features:
◆ Small size, saving space.
◆ Centrifugal fan with adjustable speed;
◆ Large LCD display: The operator can check the detailed status of the cabinet, such as the inflow and outflow speed, temperature and humidity of the working area, filter pressure, UV working time and filter working time, filter life indicator, etc.
◆ Time countdown function: After starting the cabinet, 3 waiting time can be saved, and sterilization time can be saved after the experiment.
◆ Remote control: Various functions can be realized 6 meters away from the cabinet through the remote control, which can protect the operator in emergency situations.
◆ Electric front window: The electric front window is easy to operate with one hand.
◆ Voice prompt function: air flow alarm, filter replacement alarm and front window height alarm.
◆ The sliding front window adopts a suspension lifting system, which can be lifted and positioned arbitrarily, with reliable performance and maintenance-free. It is convenient for sterilization after being closed and sealed.
◆ The working area is made of standard 304 stainless steel, and the internal arc angle is designed without clean dead corners.
◆ Adopt German imported fan, with low noise and large air volume.
◆ Using a unique high-efficiency filter, the working area reaches 100 levels, and the filtration efficiency is >99.995%.
◆ Using a unique wind speed sensor, real-time wind speed measurement, accurate and rapid display.
Model | BSC-1600B2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1800×800×2120 mm |
Working Space | 1600×700×600 mm |
Downflow Velocity | 0.35m/s |
Forward intake wind speed | 0.25m/s±0.025m/s |
BSC Biosafety Cabinet cabinets
1. Turn on the power.
2. Wear clean laboratory overalls, clean your hands, and wipe the working platform in the safety cabinet with 70% alcohol or other disinfectants.
3. Place the experimental objects in the safety cabinet as required.
4. Close the glass door, turn on the power switch, and if necessary, turn on the UV lamp to disinfect the surface of the experimental objects.
5. After the disinfection is completed, set to the working state of the safety cabinet, open the glass door to make the machine operate normally.
6. The equipment can be used after completing the self-cleaning process and running stably.
7. After finishing the work and removing the waste, wipe the working platform in the cabinet with 70% alcohol. Maintain the air circulation for a period of time to discharge pollutants in the work area.
8. Close the glass door, turn off the fluorescent lamp, and turn on the ultraviolet lamp to disinfect the cabinet.
9. After disinfection, turn off the power.
Company Details
Business Type:
Distributor/Wholesaler,Trading Company
Year Established:
2016
Total Annual:
1800000-2000000
Employee Number:
80~90
Ecer Certification:
Active Member
The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality... The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality...
Get in touch with us
Leave a Message, we will call you back quickly!