Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 10000 Set/Sets per day |
Delivery Time | 5-8 work days |
Packaging Details | Wooden case |
Tybe | BTS17-A |
Chamber volume | 17 l |
Chamber dimension | 250mm * 350mm |
Operating environment temperature | 5 ºC ~ 40 ºC |
Nominal power | 1.8 kw |
Net weight | 50 kg |
Features | Fully Automatic Self-Expanding Seal |
Advantage | High-definition digital display |
Brand Name | HAIYING |
Model Number | BTS17-A |
Certification | CE certificate |
Place of Origin | China |
View Detail Information
Explore similar products
Against Water Shortage Air Sterilization Device 23000ML
Stainless Steel Desktop Autoclave Sterilizer 17 L
17L Vertical Steam Sterilizer Autoclave LCD Display
LCD Automatic Timing Desktop Autoclave Sterilizer 23 L
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 10000 Set/Sets per day |
Delivery Time | 5-8 work days | Packaging Details | Wooden case |
Tybe | BTS17-A | Chamber volume | 17 l |
Chamber dimension | 250mm * 350mm | Operating environment temperature | 5 ºC ~ 40 ºC |
Nominal power | 1.8 kw | Net weight | 50 kg |
Features | Fully Automatic Self-Expanding Seal | Advantage | High-definition digital display |
Brand Name | HAIYING | Model Number | BTS17-A |
Certification | CE certificate | Place of Origin | China |
High Light | 17L machine used to sterilize surgical instruments ,17L medical steam sterilizer ,50KG machine used to sterilize surgical instruments |
Fully Automatic Self-Expanding Seal Desktop Autoclave Sterilizer
Desktop Autoclave Sterilizer Advantage:
◆ Large screen LCD display, optional printer
◆ High-definition digital display
◆ Five pulse vacuum, microcomputer control, touch button, power-on self-check and fault self-repair function
◆ High-end imported configuration, the number of vacuums can reach 5 times, the ultimate vacuum is -0.098Mpa, which can meet the rapid sterilization of all kinds of equipment, super long pipe fittings and wrapped dressing
◆ Powerful vacuum drying system, the residual humidity of the equipment after drying does not exceed 0.2%
◆ Two fixed programs, one custom degree, three sterilization temperatures of 121℃ and 134℃, and the sterilization time can be set by yourself
◆ With B/D test program, the vacuum leakage rate is less than 0.13kpa/min
◆ It can inactivate HIV, hepatitis B virus, spores, and perfringens
◆ Threaded screw door lock, safe and reliable, domestic first, external water filter, convenient for daily maintenance.
Model | BTS17-A |
Chamber dimension | 250mm * 350mm |
Chamber volume | 17L |
Overall dimension (L ×W ×H) | 640mm*475mm*430mm |
Net weight | 50KG |
Desktop Autoclave Sterilizer Description:
BTS17-A tabletop sterilizers are designed to perform class B cycles that meet the strictest EN 13060 European standards. Following European standards, our excellent sterilizers are designed for providing efficient class b sterilization for all types of instruments and materials including all wrapped (single and double) or unwrapped items. Our standard models of class B sterilizers are available with volume 17 to 23 liters and offers performance guarantee of unmatched quality of Class B Cycles. These systems are easy to operate and do not require any training before operating.
The end user including Dentists,Plastic surgeons,Day surgeries,Medical Surgeries,Podiatrist,Tattooist,Body Pierces,Veterinary application,Cosmetic application (Including hair or nail salons etc…)
Company Introduction:
Shandong Haiying Wuzhou Instrument Co., Ltd.
We have 15 years of experience in the operation of laboratory equipment, medical inspection and testing equipment, a mature business team, and a perfect service system. Our company adheres to the business philosophy of "Haina, Baichuan and Dadao win-win"
Desktop Autoclave Sterilizer Working principle:
The working water is sucked into the steam generator through the one-way valve, and the water is converted into steam by electric heating. The steam generator communicates with the jacket and the inner chamber, and the generated steam enters the sterilization chamber through a valve control. The air in the sterilization chamber is forced out by the vacuum device through the vacuum solenoid valve. The saturated steam enters the sterilization chamber through the steam inlet solenoid valve. The bacteria (protein-containing microorganisms) carried by the items to be sterilized are in a certain high temperature steam environment Be killed.
Company Details
Business Type:
Distributor/Wholesaler,Trading Company
Year Established:
2016
Total Annual:
1800000-2000000
Employee Number:
80~90
Ecer Certification:
Active Member
The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality... The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality...
Get in touch with us