Payment Terms | T/T, Western Union |
Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days |
Packaging Details | 1pc/pouch, 25pcs/box |
Method | Gold Colloidal |
Format | 5 Multiple panel |
Specimen | Urine |
Testing time | 5-15 minutes |
Shelf Life | 24 Months |
Application | 5 drugs |
Brand Name | New Life |
Model Number | Panel |
Certification | ISO13485, CE |
Place of Origin | China |
View Detail Information
Explore similar products
TML Urine Drug Abuse Test Kit Gold Colloidal 100ng/Ml Cut Off Qualitative
Professional Tramadol Test Kit Rapid Diagnostic Card Format 24 Month Shelf Life
Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine
CE Approved Portable Drug Test Kits 4mm Dipcard 500ng/ML Cut - Off For Ecstasy
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days | Packaging Details | 1pc/pouch, 25pcs/box |
Method | Gold Colloidal | Format | 5 Multiple panel |
Specimen | Urine | Testing time | 5-15 minutes |
Shelf Life | 24 Months | Application | 5 drugs |
Brand Name | New Life | Model Number | Panel |
Certification | ISO13485, CE | Place of Origin | China |
High Light | self testing drug kits , drug test strips |
10 Panel Drug Test is competitive binding, lateral flow immunochromatographic assay for qualitative and simultaneous detection of Amphetamine, Oxazepam, Cocaine, Cannabinoids, Methamphetamine, Morphine, Oxycodone, EDDP, Secobarbital, Buprenorphine, Methylenedioxymethamphetamine, Phencyclidine, Propoxyphene , Nortriptyline and Methadone in human urine.
The test may yield positive results for the prescription drugs Buprenorphine, Oxazepam, Secobarbital and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between prescription use or abuse of these drugs. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive. The test provides only preliminary test results. A more specific alternative chemical method may be used in order to obtain a confirmed analytical result. GC/MS or LC/MS is the preferred confirmatory method. For
Product | Cat No | Specimen | Sensitivity | Format | Kit Size |
Drugs of Abuse (DOA) Tests | |||||
AMP | YD101S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD101C4 | 4mm Cassette | 25T | |||
BAR | YD201S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD201C4 | 4mm Cassette | 25T | |||
BZO | YD301S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD301C4 | 4mm Cassette | 25T | |||
COC | YD401S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD401C4 | 4mm Cassette | 25T | |||
MOR(MOP) | YD501S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD501C4 | 4mm Cassette | 25T | |||
MET | YD601SM | Urine | 500 ng/mL | 3mm Strip | 100T |
YD601CM | 4mm Cassette | 25T | |||
MTD | YD701S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD701C4 | 4mm Cassette | 25T | |||
MDMA | YD801S3 | Urine | 500 ng/mL | 3mm Strip | 100T |
YD801C4 | 4mm Cassette | 25T | |||
THC | YD901S3 | Urine | 50 ng/mL | 3mm Strip | 100T |
YD901C4 | 4mm Cassette | 25T | |||
BUP | YD111S3 | Urine | 100 ng/mL | 3mm Strip | 100T |
YD111C4 | 4mm Cassette | 25T | |||
PCP | YD121S3 | Urine | 25 ng/mL | 3mm Strip | 100T |
YD121C4 | 4mm Cassette | 25T | |||
K2 | YD131S3 | Urine | 200 ng/mL | 3mm Strip | 100T |
YD131C4 | 4mm Cassette | 25T | |||
OPI | YD141S3 | Urine | 2000 ng/mL | 3mm Strip | 100T |
YD141C4 | 4mm Cassette | 25T | |||
TCA | YD151S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD151C4 | 4mm Cassette | 25T | |||
KET | YD161S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD161C4 | 4mm Cassette | 25T | |||
TML | YD171S3 | Urine | 100 ng/mL | 3mm Strip | 100T |
YD171C4 | 4mm Cassette | 25T | |||
DOA 2-in-1 | YD021C5 | Urine | See Insert | 2-in-1 Panel | 25T |
DOA 3-in-1 | YD031C5 | Urine | See Insert | 3-in-1 Panel | 25T |
DOA 4-in-1 | YD041C5 | Urine | See Insert | 4-in-1 Panel | 25T |
DOA 5-in-1 | YD051C5 | Urine | See Insert | 5-in-1 Panel | 25T |
DOA 6-in-1 | YD061C5 | Urine | See Insert | 6-in-1 Panel | 25T |
DOA 7-in-1 | YD071C5 | Urine | See Insert | 7-in-1Panel | 25T |
DOA 8-in-1 | YD081C5 | Urine | See Insert | 8-in-1Panel | 25T |
DOA 9-in-1 | YD091C5 | Urine | See Insert | 9-in-1 Panel | 25T |
DOA 10-in-1 | YD011C5 | Urine | See Insert | 10-in-1 Panel | 25T |
Alcohol | YD151C5 | Saliva | See Insert | Strip | 100T |
DIRECTIONS FOR USE
If refrigerated, allow the test device to come to room temperature, 59-86°F (15-30°C) prior to testing. 1) Remove the Clarity Multi-Drug Urine Test Dip Card from the foil wrapper. 2) Fill a specimen cup (not provided) with fresh urine. Dip the Clarity Multi-Drug Urine Test Dip Card into the urine with the arrow end pointing toward the urine. Do not cover the urine over the MAX (maximum) line. You may leave the Clarity Multi-Drug Urine Test Dip Card in the urine or you may take the Dip Card out after a minimum of 15 seconds in the urine and lay the Dip Card flat on a non-absorptive clean surface. 3) Read results at 5 minutes and do not throw away the urine. Urine used may be needed for confirmation testing.
Summary:
The test is intended for use as the process to provide health care professionals and consumers with information concerning the presence or absence of the above stated drugs in a urine sample.
METHAMPHETAMINE(MET,mAMP) Methamphetamine is an addictive stimulant drug that strongly activates certain systems in the brain. Methamphetamine is closely related chemically to amphetamine, but the central nervous system effects of Methamphetamine are greater.Methamphetamine is made in illegal laboratories and has a high potential for abuse and dependence. The drug can be taken orally, injected, or inhaled. Acute higher doses lead to enhanced stimulation of the central nervous system and induce euphoria, alertness, reduced appetite, and a sense of increased energy and power. Cardiovascular responses to Methamphetamine include increased blood pressure and cardiac arrhythmias. More acute responses produce anxiety, paranoia, hallucinations, psychotic behavior, and eventually, depression and exhaustion. The effects of Methamphetamine generally last 2-4 hours and the drug has a half-life of 9-24hoursin the body.Methamphetamine is excreted
in the urine as amphetamine and oxidized and delaminated derivatives. However, 10-20% of Methamphetamine is excreted unchanged. Thus, the presence of the parent compound in the urine indicates Methamphetamine use.
COCAINE(COC) Cocaine is a potent central nervous system(CNS) stimulant and a local anesthetic. Initially, it brings about extreme energy and restlessness while gradually resulting in tremors, over-sensitivity and spasms. In large amounts, cocaine causes fever, unresponsiveness, difficulty in breathing and unconsciousness.
Opiate(OPI) Opiate refers to any drug that is derived from the opium poppy, including the natural products, morphine and codeine, and the semi-synthetic drugs such as heroin. Opioid is more general, referring to any drug that acts on the opioid receptor. Opioid analgesics comprise a large group of substances which control pain by depressing the central nervous system. Large doses of morphine can produce higher tolerance levels, physiological dependency in users, and may lead to substance abuse. Morphine is excreted unmetabolized, and is also the major metabolic product of codeine and heroin. Morphine is detectable in the urine for several days after an opiate dose.
MARIJUANA(THC) THC ( 9--tetrahydrocannabinol) is the primary active ingredient in cannabinoids (marijuana). When smoked or orally administered, it produces euphoric effects. Users have impaired short term memory and slowed learning.They may alsoexperience transient episodes of confusion and anxiety. Long term relatively heavy use may be associated with behavioral disorders. The peak effect of smoking marijuana occurs in 20-30 minutes and the duration is 90-120 minutes after one cigarette. Elevated levels of urinary metabolites are found within hours of exposure and remain detectable for 3-10 days after smoking. The main metabolite excreted in the urine is 11-nor- 9-tetrahydrocannabinol-9-carboxylic acid ( 9-THC-COOH).
BENZODIAZEPINES(BZO) Benzodiazepines are medications that are frequently prescribed for the symptomatic treatment of anxiety and sleep disorders. They produce their effects via specific receptors involving a neurochemical called gamma aminobutyric acid (GABA). Becausethey are safer and more effective, Benzodiazepines have replaced barbiturates in the treatment of both anxiety and insomnia. Benzodiazepines are also used as sedatives before some surgical and medical procedures, and for the treatment of seizure disorders and alcohol withdrawal. Risk of physical dependence increases if Benzodiazepines are taken regularly (e.g., daily) for more than a few months, especially at higher than normal doses. Stopping abruptly can bring on such symptoms as trouble sleeping, gastrointestinal upset, feeling unwell, loss of appetite, sweating, trembling, weakness, anxiety and changes in perception. Only trace amounts (less than 1%) of most Benzodiazepines are excreted unaltered in the urine; most of the concentration in urine is conjugated drug. The detection period for the Benzodiazepines in the urine is 3-7days.
INTERPRETATION OF RESULTS
NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.
*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.
POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.
INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.
QUALITY CONTROL
If you work in a laboratory, you should perform quality control testing and you should read this section.
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
10,000,000-15,000,000
Employee Number:
200~300
Ecer Certification:
Active Member
Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...
Get in touch with us
Leave a Message, we will call you back quickly!