China CTnI Rapid Diagnostic Blood Test Strips Gold Colloidal Easy Operation For
China CTnI Rapid Diagnostic Blood Test Strips Gold Colloidal Easy Operation For

  1. China CTnI Rapid Diagnostic Blood Test Strips Gold Colloidal Easy Operation For
  2. China CTnI Rapid Diagnostic Blood Test Strips Gold Colloidal Easy Operation For

CTnI Rapid Diagnostic Blood Test Strips Gold Colloidal Easy Operation For

  1. MOQ: 5000pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 2000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Category Cardiac
Format Strip/cassette
Specimen Whole Blood/Serum/Plasma
Testing time 5-15 minutes
Shelf Life 24 Months
Application cTnl
Accuracy 99.1%
Brand Name New Life
Model Number cassette
Certification ISO13485,CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 2000000pcs/month
Delivery Time 20-30days Packaging Details 1pc/pouch, 25pcs/box
Category Cardiac Format Strip/cassette
Specimen Whole Blood/Serum/Plasma Testing time 5-15 minutes
Shelf Life 24 Months Application cTnl
Accuracy 99.1% Brand Name New Life
Model Number cassette Certification ISO13485,CE
Place of Origin China
High Light heart disease blood testdiagnostic heart tests

One Step cTnI Rapid Diagnostic Test, detection of bedside Troponin I, gold colloidal method,quickly

 

 

 

Intended Use:

 

 

For the rapid qualitative detection of cardiac troponin I (cTnI) in human whole blood, serum and plasma as an aid in the diagnosis of myocardial infarction in emergency room, critical care, point-of-care, and hospital settings.

The Troponin I Assay provides a qualitative analytical test result. The qualitative nature of this assay does not provide information about change - either the rise or fall - in the concentration of cTnI with single testing. Aquantitative method should be used, if desired, to determine the concentration of cTnI at any given time. Only with serial testing could a temporal change in the level of cTnI be concluded. Clinical consideration and professional judgement should be applied when interpreting the results of the Troponin I Assay, especially when single testing results are used.

 

 

SUMMARY:

 

 

The troponin complex is formed of three subunits, troponin T (TnT), troponin C (TnC) and Troponin I (TnI). The three troponin subunits have distinct functions with TnC as the Ca++-binding, TnT as the tropomyosin binding, and TnI as the inhibitory subunits.1 The troponin complex, together with tropomyosin, form the main component that regulates the Ca++-sensitive ATPase activity of actomyosin in striated muscle (skeletal and cardiac). Different isoforms of TnI exist in the skeletal and cardiac muscles (sTnI and cTnI, respectively) with distinct structural heterogeneity between these isoforms that allow the production of isoform-specific antibodies.These isoform-specific antibodies have been utilized to assemble various detection methods that are isoform-specific. Recent reports have investigated the utility of determining the serum levels of the different isoforms of TnI.

 

Detection of cTnI in the serum was investigated as an aid in the determination of myocardial damage in patients with acute myocardial infarction (AMI).5 Several clinical reports have demonstrated the diagnostic value of determining the serum level of cTnI in identifying patients with AMI. The temporal relation of release of cTnI into the serum has been investigated and compared to the other established cardiac markers such as CK-MB, myoglobin and TnT.6,7 Cumulative data from several reports documented that in patients with AMI, cTnI is released into the circulation with levels exceeding the upper reference limit of normal 4-6 hours after the onset of symptoms and peak levels are reached after 12-24 hours.8 This early release profile is similar to CK-MB. However, CK-MB levels return to normal values after 72 hours, while levels of cTnI remains elevated for up to 5-7 days. Due to the distinct structure of cTnI and the availability of highly-specific detection methods for cTnI, the utility of this marker for the diagnosis of AMI in complex clinical conditions that involve skeletal muscle damage have been investigated. The high specificity of cTnI measurements for the identification of myocardial damage has been demonstrated in conditions such as perioperative period, after marathon runs, and blunt chest trauma. The release of cTnI into blood has been documented in clinical conditions that involve myocardial damage, other than AMI, such as unstable angina, congestive heart failure, and ischaemic damage due to coronary artery by-pass surgery. Measurements of cTnI have been investigated and documented to be valuable in identifying patients with AMI presenting to the ED with chest pain.

 

 

Test Principle:

 

Troponin I Test employs solid-phase chromatographic immunoassay technology to qualitatively detect the presence of cTnI above an established cutoff level in human blood, serum and plasma samples. After a specimen has been dispensed into the sample well, plasma or serum is transferred into a region containing monoclonal anti-cTnI antibody-dye conjugates and rabbit polyclonal anti-cTnI antibodies. These antibodies bind to cTnI in the sample to form complexes, which migrate through the reaction strip. The antigen/antibody dye complexes are then captured by immobilized avidin in the TnI area. Additional protein-dye conjugates not bound in the Test (TnI) area are later captured in the Control (C) area.

Visible purplish horizontal bands will appear in the TnI and C areas if the level of cTnI is above the established cutoff level. Avisible purplish band in the C area indicates the assay is working properly. If a band is present only in the C area, the result is read as negative, indicating that the level of cTnI is below the cutoff level. If no band is present in the C area, the test should be considered invalid and another test must be run, regardless of the presence or absence of a band in the TnI area.

 

 

TEST PROCEDURE

 

 

 

 

INTERPRETATION OF RESULTS

 

POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

 

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

 

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

PERFORMANCE CHARACTERS:

 

 

Sensitivity and Specificity

The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) has been evaluated with a leading commercial cTnI EIA test using clinical specimens. The results show that the sensitivity of the Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is 98.3% and the specificity is 98.4% relative to the leading EIA test.

 

Troponin I Rapid Test Device vs. EIA

 

 

Method EIA Test

Total

Results

Troponin I Rapid Test Device Results Positive Negative
Positive 113 6 119
Negative 2 493 495
Total Results 115 499 614

 

Relative Sensitivity: 98.3%(93.9%-99.8%)*

 

Relative Specificity: 98.4%(97.4%-99.6%)*

 

Accuracy: 98.7%(97.5%-99.4%)*

 

*95% Confidence Interval

 

 
ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    10,000,000-15,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...

+ Read More

Get in touch with us

  • Reach Us
  • Orient New Life Medical Co.,Ltd.
  • 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
  • https://www.medicaldiagnostictestkits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement