Payment Terms | T/T, Western Union |
Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days |
Packaging Details | 1pc/pouch, 25pcs/box |
Category | Cardiac test |
Format | cassette |
Specimen | Whole Blood/Serum/Plasma |
Testing time | 5-15 minutes |
Shelf Life | 24 Months |
Application | Troponin I |
Accuracy | 98.9% |
Brand Name | New Life |
Model Number | cassette |
Certification | ISO13485,CE |
Place of Origin | China |
View Detail Information
Explore similar products
Portrable H FABP Rapid Test Blood Specimen 4mm Strip 5 Mins Reading Time
D-Dimer Cardiac Blood Tests Convenient One Step Quickly Operate For Vitro
Gold Colloidal Myoglobin Blood Test Home High Accuracy Kit Qualitative Detection
Lightweight CRP Test Kit 5-15 Mins Testing Time 10 μG/Ml Cutoff Rapid Diagnostic
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days | Packaging Details | 1pc/pouch, 25pcs/box |
Category | Cardiac test | Format | cassette |
Specimen | Whole Blood/Serum/Plasma | Testing time | 5-15 minutes |
Shelf Life | 24 Months | Application | Troponin I |
Accuracy | 98.9% | Brand Name | New Life |
Model Number | cassette | Certification | ISO13485,CE |
Place of Origin | China | ||
High Light | heart disease blood test ,heart related blood tests |
High accuracy One Step Troponin I Rapid Diagnostic Test, diagnosis of myocardial infarction (MI),quickly
Intended Use:
The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human cardiac Troponin I in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).
Test Principle:
The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of cTnI in whole blood, serum or plasma. The membrane is pre-coated with capture reagent on the test line region of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with anti-cTnI antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with capture reagent on the membrane and generate a colored line. The presence of this colored line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
TEST PROCEDURE
1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready
to begin testing.
2. Remove the device from the sealed pouch and lay it on a flat and dry surface.
3. Using the provided pipette, add one drop of fresh specimen to the sample well.
4. Hold the buffer bottle vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2-3 drops of buffer to the sample well.
5. Read the result between 15-20minutes. Do not read results after 20 minutes.
INTERPRETATION OF RESULTS
POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
PERFORMANCE CHARACTERS:
Sensitivity and Specificity
The Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) has been evaluated with a leading commercial cTnI EIA test using clinical specimens. The results show that the sensitivity of the Troponin I Rapid Test Device (Whole Blood/Serum/Plasma) is 98.3% and the specificity is 98.4% relative to the leading EIA test.
Troponin I Rapid Test Device vs. EIA
Method | EIA Test |
Total Results |
||
Troponin I Rapid Test Device | Results | Positive | Negative | |
Positive | 113 | 6 | 119 | |
Negative | 2 | 493 | 495 | |
Total Results | 115 | 499 | 614 |
Relative Sensitivity: 98.3%(93.9%-99.8%)*
Relative Specificity: 98.4%(97.4%-99.6%)*
Accuracy: 98.7%(97.5%-99.4%)*
*95% Confidence Interval
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
10,000,000-15,000,000
Employee Number:
200~300
Ecer Certification:
Active Member
Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...
Get in touch with us
Leave a Message, we will call you back quickly!