China factories

China factory - Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd.

  • China,Ningbo ,Zhejiang
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip
China 16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip

  1. China 16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip
  2. China 16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip
  3. China 16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip

16 Panel Self Testing Drug Kits 15 Urine Drug Test Plus Adulterant Strip

  1. MOQ: 5000pcs
  2. Price: USD0.5-USD5
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 2000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Method Gold Colloidal
Format 16 panel Multiple panel
Specimen Urine only
Testing time 3-5 minutes
Shelf Life 2 Years
Application 16 drugs test
Brand Name New Life
Model Number Panel
Certification ISO13485, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 2000000pcs/month
Delivery Time 20-30days Packaging Details 1pc/pouch, 25pcs/box
Method Gold Colloidal Format 16 panel Multiple panel
Specimen Urine only Testing time 3-5 minutes
Shelf Life 2 Years Application 16 drugs test
Brand Name New Life Model Number Panel
Certification ISO13485, CE Place of Origin China
High Light self testing drug kitsdrug test strips

 

16 panel Drug Abuse test kit 15 urine drug test plus adulterant strip

 

 

Intended Use

 

The Multi-drug Rapid Test Panel (Urine) is rapid chromatographic immunoassays for the qualitative and simultaneous detection up to sixteen of the following drugs in human urine. The designed cutoff concentrations for these drugs are as follows:

 

Test Cut-off (ng/mL)
AMP(Amphetamine) 500
THC(Marijuana) 50
COC (Cocaine) 200
PCP(Phencyclidine) 25
MOR(Morphine) 200
MET(Methamphetamine ) 500
MTD(Methadone) 300
BZO(Oxazepam) 200
BUP(Buprenorphine) 5
ETG(Ethylglucoronide) 1000
TML(Tramadol) 100
COT(Cotinine) 300
FYL(Fentanyl) 100
OXY (Oxycodone) 100
PGB (Pregabalin) 500
Adulteration ( Oxidants,Specific Gravity,pH) /

 

 

Principle

 

The Multi-drug Rapid Test Panel (Urine) is one-step immunoassay in which chemically labeled drugs (drug-protein conjugates) compete for limited antibody binding sites with drugs which may be present in urine. The test panel contains membrane strips which are pre-coated with drug-protein conjugates on the test band(s). Each strip, the drug antibody-colloidal gold conjugate pad is placed at one end of the membrane. In the absence of drug in the urine, the solution of the colored antibody-colloidal gold conjugate move along with the sample solution upward chromatographically by capillary action across the membrane to the immobilized drug-protein conjugate zone on the test band region. The colored antibody-gold conjugate then attach to the drug-protein conjugates to form visible lines as the antibody complex with the drug conjugate. Therefore, the formation of the visible precipitant in the test zone occurs when the test urine is negative for the drug.When the drug is present in the urine, the drug/metabolite antigen competes with drug-protein conjugate on the test band region for the limited antibody. When a sufficient concentration of the drug is present, it will fill the limited antibody binding sites. This will prevent attachment of the colored antibody (drug-protein conjugate)-colloidal gold conjugate to the drug-protein conjugate zone on the test band region. Therefore, absence of the color band on the test region indicates a positive result.A control band with a different antigen/antibody reaction is added to the immunochromatographic membrane strip at the control region (C) to indicate that the test has performed properly. This control line should always appear regardless of the presence of drug or metabolite. If the control line does not appear the test panel should be discarded.

Adulteration is the tampering of a urine specimen with the intention of altering the test results. The use of adulterants can cause false negative results in drug tests by either interfering with the screening test and/or destroying the drugs present in the urine. Dilution may also be employed in an attempt to produce false negative drug test results.One of the best ways to test for adulteration or dilution is to determine certain urinary characteristics such as pH, and Specific Gravity and to detect the presence of Oxidants in urine.

 

 

INTERPRETATION OF RESULTS

 

 

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

Cross Reactivity

 

A study was conducted to determine the cross-reactivity of the test with compounds in either drug-free urine or drug positive urine containing, Amphetamine, Barbiturates, Benzodiazepines, Buprenorphine, Cocaine, Marijuana, Methadone, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Tramadol , Methaqualone, Ketamine ,Phencyclidine, Propoxyphene or Tricyclic Antidepressants. The following compounds show no cross-reactivity when tested with the Multi-Drug Rapid Test Panel with Adulteration at a concentration of 100 µg/mL. Visual interpretations occurred at 5 minutes after specimen application. Results are presented in table below.

 

Table: Cross Reactivity

Acetophenetidin Cortisone Zomepirac d-Pseudoephedrine
N-Acetylprocainamide Creatinine Ketoprofen Quinidine
Acetylsalicylic acid Deoxycorticosterone Labetalol Quinine
Aminopyrine Dextromethorphan Loperamide Salicylic acid
Amoxicillin Diclofenac Meprobamate Serotonin
Ampicillin Diflunisal Methoxyphenamine Sulfamethazine
l-Ascorbic acid Digoxin Methylphenidate Sulindac
Apomorphine Diphenhydramine Nalidixic acid Tetracycline
Aspartame Ethyl-p-aminobenzoate Naproxen Tetrahydrocortisone,
Atropine b-Estradiol Niacinamide 3-acetate
Benzilic acid Estrone-3-sulfate Nifedipine Tetrahydrocortisone
Benzoic acid Erythromycin Norethindrone Tetrahydrozoline
Bilirubin Fenoprofen Noscapine Thiamine
d,l-Brompheniramine Furosemide d,l-Octopamine Thioridazine
Caffeine Gentisic acid Oxalic acid d,l-Tyrosine
Cannabidiol Hemoglobin Oxolinic acid Tolbutamide
Chloral hydrate Hydralazine Oxymetazoline Triamterene
Chloramphenicol Hydrochlorothiazide Papaverine Trifluoperazine
Chlorothiazide Hydrocortisone Penicillin-G Trimethoprim
d,l-Chlorpheniramine o-Hydroxyhippuric acid Perphenazine d,l-Tryptophan
Chlorpromazine 3-Hydroxytyramine Phenelzine Uric acid
Cholesterol d,l-Isoproterenol Prednisone Verapamil
Clonidine Isoxsuprine d,l-Propanolol  
 

Conclusion: The compounds listed in above table show no cross-reactivity when tested at a concentration of 100 mg/ml in 5 minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    10,000,000-15,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...

+ Read More

Get in touch with us

  • Reach Us
  • Orient New Life Medical Co.,Ltd.
  • 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
  • https://www.medicaldiagnostictestkits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement