Payment Terms | T/T, Western Union |
Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days |
Packaging Details | 1pc/pouch, 25pcs/box |
Category | Home kits testing |
Format | kits home |
Specimen | Oral fluid |
Testing time | 5-15 minutes |
Shelf Life | 24 Months |
Application | HIV oral fluid home use |
Accuracy | 99.30% |
Brand Name | New Life |
Certification | ISO13485, CE |
Place of Origin | China |
View Detail Information
Explore similar products
One step High Accuracy Chlamydia Rapid Diagnostic test Cassette , gold colloidal
4mm Cassette Home Testing Kits CE , Home Aids Test Kit For Carcinoembryonic
Tumor Mark PSA Home Testing Kits Semi - Quantitative Detection For Prostate
Digital Gonorrhea Home Test Kit 24 Months Testing Time Detect Private Disease
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days | Packaging Details | 1pc/pouch, 25pcs/box |
Category | Home kits testing | Format | kits home |
Specimen | Oral fluid | Testing time | 5-15 minutes |
Shelf Life | 24 Months | Application | HIV oral fluid home use |
Accuracy | 99.30% | Brand Name | New Life |
Certification | ISO13485, CE | Place of Origin | China |
High Light | home medical test kits ,home health test kits |
Private use HIV Oral fluid self test kit, testing for private disease, easily and safe, 99% accuracy, personal package
INTENDED USE:
The HIV Oral fluid self test kit is a point-of-care test to aid in the diagnosis of infection with HIV-1 and HIV-2. This rapid HIV test provides results with 99.30% accuracy from oral fluid in as little as 20 minutes, thus providing results during the initial visit and enabling immediate counseling. Additionally, this test will be useful for pregnant women who do not know their HIV status at the time of delivery and for health care workers after accidental exposures to body fluids from infected individuals.
INTRODUCTION
The HIV Oral fluid self test kit utilizes a proprietary lateral flow immunoassay procedure. The device’s plastic housing holds an assay test strip comprised of several materials that provide the matrix for the immunochromatography of the specimen and the platform for indication of the test results. The assay test strip, which can be viewed through the test device result window, contains synthetic peptides representing the HIV envelope region in the Test (T) zone and a goat anti-human IgG in the Control (C) zone immobilized onto a nitrocellulose membrane.
TEST PRINCIPLE
An oral fluid specimen is collected using the flat pad on the test device, followed by insertion into the developer solution. Alternatively, a finger-stick or venipuncture whole blood specimen is collected and transferred into the vial of developer solution, followed by the insertion of the test device. The developer solution facilitates the flow of the specimen into the device and onto the test strip. As the diluted specimen flows through the device, it re-hydrates the protein-A gold colorimetric reagent contained in the device. As specimen continues to migrate up the strip, it encounters the T zone. If the specimen contains antibodies that react with the antigens immobilized on the nitrocellulose membrane, a reddish-purple line will appear, qualitatively indicating the presence of antibodies to HIV-1 and/or HIV-2 in the specimen. The intensity of the line color is not directly proportional to the amount of antibody present in the specimen. Further up the assay strip, the sample will encounter the C zone. This built-in procedural control serves to demonstrate that a specimen was added to the vial and that the fluid has migrated adequately through the test device. A reddish-purple line will appear in the C zone during the performance of all valid tests, whether or not the sample is positive or negative for antibodies to HIV-1 and/or HIV-2.
The test results are interpreted after 20 minutes but not more than 40 minutes after the introduction of the test device containing the test specimen into the developer solution.
TEST PROCEDURE
QUALITY CONTROL
Built-in Control Features
HIV Oral fluid self test kit has a built-in procedural control that demonstrates assay validity. A reddishpurple line in the Control (“C”) area of the Result Window indicates that a specimen was added and that the fluid migrated appropriately through the Test Device. The Control line will appear on all valid tests, whether or not the sample is reactive or nonreactive. (Refer to Test Result and Interpretation of Test Result section below.)
External Quality Control
HIV Oral fluid self test kit Controls are available separately for use only with the HIV Oral fluid self test kit. The Kit Controls are specifically formulated and manufactured to ensure performance of the Test, and are used to verify your ability to properly perform the test and interpret the results. The HIV-1 and HIV-2 Positive Controls will produce a reactive test result and have been manufactured to produce a very faint Test (“T”) line. The Negative Control will produce a nonreactive test result. (Refer to Test Result and Interpretation of Test Result section below.) Use of kit control reagents manufactured by any other source may not produce the required results, and therefore, will not meet the requirements for an adequate quality assurance program for the HIV Oral fluid self test kit.
PERFORMANCE STUDY
Detection of Antibody to HIV-1 in Oral Fluid Specimens from HIV-1 Seropositive Individuals
Total | Repeatedly | True Positive1 | ||
Test Group | Samples | Reactive | Reactive | |
Known HIV-1 | ||||
Positive | 767 | 762 | 764 | 767 |
High-Risk | 3150 | 722 | 743 | 73 |
TOTAL | 3917 | 834 | 838 | 840 |
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
10,000,000-15,000,000
Employee Number:
200~300
Ecer Certification:
Active Member
Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...
Get in touch with us
Leave a Message, we will call you back quickly!