China Lysergic Acid Rapid Test 4mm Cassette Drug Abuse Test Kit Cut - Off 20ng/Ml
China Lysergic Acid Rapid Test 4mm Cassette Drug Abuse Test Kit Cut - Off 20ng/Ml

  1. China Lysergic Acid Rapid Test 4mm Cassette Drug Abuse Test Kit Cut - Off 20ng/Ml
  2. China Lysergic Acid Rapid Test 4mm Cassette Drug Abuse Test Kit Cut - Off 20ng/Ml

Lysergic Acid Rapid Test 4mm Cassette Drug Abuse Test Kit Cut - Off 20ng/Ml

  1. MOQ: 5000pcs
  2. Price: USD0.5-USD5
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 2000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Category Drug Abuse TESGTING kits
Format CARD lsd 3mm
Specimen Urine
Testing time 5 minu
Shelf Life 24 Months
application LSD drug test
cut-off 20ng/ml
Brand Name New Life
Model Number LSD
Certification ISO13485, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 2000000pcs/month
Delivery Time 20-30days Packaging Details 1pc/pouch, 25pcs/box
Category Drug Abuse TESGTING kits Format CARD lsd 3mm
Specimen Urine Testing time 5 minu
Shelf Life 24 Months application LSD drug test
cut-off 20ng/ml Brand Name New Life
Model Number LSD Certification ISO13485, CE
Place of Origin China
High Light self testing drug kits drug test strips

Drug Abuse Test Kit Lysergic Acid Rapid Test 4mm cassette ,high sensitivity cut-off 20ng/ml

 

Product Name

 

LSD ( Lysergic Acid) Rapid Diagnostic Test

Specimen: Urine

 

 

Intended Use

 

The LSD Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the detection of Lysergic Acid Diethylamide in human urine at a cut-off concentration of 20 ng/mL.

 

This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) or Liquid Chromatography/mass spectrometry (LC/MS) are the preferred confirmatory methods. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Parameter Calibrator Cut-off (ng/mL)
LSD Lysergic Acid 20

 

 

 

Test Principle

 

The LSD Rapid Test Panel (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

 

During testing, a urine specimen migrates upward by capillary action. Lysergic Acid Diethylamide, if present in the urine specimen below 20 ng/mL, will not saturate the binding sites of antibody-coated particles in the test. The antibody-coated particles will then be captured by immobilized Lysergic Acid Diethylamide conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Lysergic Acid Diethylamide level exceeds 20 ng/mL because it will saturate all the binding sites of anti-Lysergic Acid Diethylamide antibodies.

 

A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration lower than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.

 

DIRECTIONS FOR USE

 

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, color will migrate across the membrane.

Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

 

INTERPRETATION OF RESULTS

 

 

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

 

 

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

 

 

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

 

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

 

QUALITY CONTROL

 

A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

 

performance characteristics

 

A side-by-side comparison was conducted using the Rapid Test Cassette (Urine) and GC/MS. The following results were tabulated:

 

 

Table 1: Specimen Correlation

 

 

Method     GC/MS Total Results
    Results Positive   Negative  
LSD Rapid Test Panel   Positive 33   1 34
    Negative 2   64 66
Total Results     35   65 100
% Agreement   94.3%   98.5% 97.0%


 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    10,000,000-15,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...

+ Read More

Get in touch with us

  • Reach Us
  • Orient New Life Medical Co.,Ltd.
  • 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
  • https://www.medicaldiagnostictestkits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement