China Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine
China Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine

  1. China Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine
  2. China Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine

Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine

  1. MOQ: 5000pcs
  2. Price: USD0.5-USD5
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 2000000pcs/month
Delivery Time 20-30days
Packaging Details 1pc/pouch, 25pcs/box
Method rapid test
width 4mm
Specimen Urine
Testing time 5-15 minutes
Shelf Life 24 Months
application MOP
Brand Name New Life
Model Number Dipcard/cassette/strip
Certification ISO13485, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 2000000pcs/month
Delivery Time 20-30days Packaging Details 1pc/pouch, 25pcs/box
Method rapid test width 4mm
Specimen Urine Testing time 5-15 minutes
Shelf Life 24 Months application MOP
Brand Name New Life Model Number Dipcard/cassette/strip
Certification ISO13485, CE Place of Origin China
High Light self testing drug kits drug test strips

Drug Abuse Test Kit MOP(MORPHINE) Rapid Diagnostic Test strip ,4mm test strip detecting MORPHINE in urine,
 
 
Intended Use
 
 
Opioid analgesics comprise a large group of substances, which control pain by depressing the central nervous system. Large doses of Morphine can produce higher tolerance levels and physiological dependency in users, and may lead to substance abuse. Morphine is excreted unmetabolized, and is also the major metabolic product of codeine and heroin. Morphine is detectable in the urine for several days after an opiate dose.1
The MOP One Step Morphine Test Strip (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Morphine in urine. The MOP One Step Morphine Test Strip (Urine) yields a positive result when Morphine in urine reaches 300 ng/mL. This is the suggested screening cut-off for positive specimens set by the Substance Abuse and Mental Health Services Administration .
 

ParameterCalibratorCut-off (ng/mL)
MOR 300 (Morphine/Heroin)Morphine300

 
 
Test Principle
 
The MOP One Step Morphine Test Strip (Urine) is an immunoassay based on the principle of competitive binding. Drugs, which may be present in the urine specimen, compete against the drug conjugate for binding sites on the antibody.
During testing, a urine specimen migrates upward by capillary action. Morphine, if present in the urine specimen below 300 ng/mL, will not saturate the binding sites of the antibody coated particles in the test strip. The antibody coated particles will then be captured by immobilized Morphine conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Morphine level is at or above 300 ng/mL because it will saturate all the binding sites of anti-Morphine antibodies.
A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that the proper volume of specimen has been added and membrane wicking has occurred.
 
DIRECTIONS FOR USE
 
Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.
Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.
Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
As the test begins to work, color will migrate across the membrane.
Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes
 
INTERPRETATION OF RESULTS
 
(Please refer to the illustration above)
NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.
*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.
POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.
INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.
 
 
QUALITY CONTROL
 
A procedural control is included in the test. A line appearing in the control region
(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.
Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.
 
performance characteristics
 
Analytical Sensitivity
 
A drug-free urine pool was spiked with Morphine at the following concentrations: 0 ng/mL, 150 ng/mL, 225 ng/mL, 300 ng/mL, 375 ng/mL, 450 ng/mL and 600ng/mL. The result demonstrates > 99% accuracy at 50% above and 50% below the cut-off concentration. Results are presented in Table 2 below.
 
Table 2: Analytical Sensitivity Summary

MOP Concentration (ng/mL)Percent of Cut-offnVisual Result
NegativePositive
0030300
150-50%30300
225-25%30255
300Cut-off301713
375+25%30129
450+50%30030
600+100%30030

 
Conclusion: As indicated in table above: all specimens with MOP concentration equal to or lower than 150ng/mL show negative results, all specimens with MOP concentration of 300ng/mL are identified as “+/-”, and all specimens with MOP concentration equal to or higher than 450ng/mL showed positive results. Therefore, the cut-off concentration of the MOP One Step Morphine Test Strip (Urine) is determined to be 300ng/mL MOP.

 
Analytical Specificity
 

Table 3 lists the compounds that are positively detected in urine by the MOP One Step Morphine Test Strip (Urine) at 5 minutes and the concentrations at which they are detected.

 


Table 3: Analytical Specificity

Compound Concentration (ng/mL)Compound Concentration (ng/mL)
Codeine300Morphine 3-b-D-glucuronide1,000
Ethylmorphine6,250Norcodeine6,250
Hydrocodone50,000Normorphone100,000
Hydromorphone3,125Oxycodone30,000
Levorphanol1,500Oxymorphone100,000
Thebaine6,250Procaine15,000
Morphine3006-Monoacethylmorphine400

 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry


















































Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    10,000,000-15,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...

+ Read More

Get in touch with us

  • Reach Us
  • Orient New Life Medical Co.,Ltd.
  • 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
  • https://www.medicaldiagnostictestkits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement