Payment Terms | T/T, Western Union, MoneyGram |
Supply Ability | 30000units/year |
Delivery Time | Within 3 days |
Packaging Details | Anti-collision film+ Carton box Carton box dimension: 40*30*35cm Gross weight: 6.30kg |
Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP |
Weight | 3.55kg(with build-in two channel thermal printer) |
Size | 12.1 inch portable maternal fetal monitor |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like. |
Optional | mobile stand/wall mount |
Brand Name | RAINBOW |
Model Number | PM-9000E |
Certification | ISO13485, FSC |
Place of Origin | Hunan, China |
View Detail Information
Explore similar products
8 Inch TFT Patient Vital Signs Monitor SPO2 Pulse Rate Multipara Monitor With
ICU Vital Sign Multi Parameter Patient Monitor Plug In Hospital Devices
10.1 Inch Multi Para Patient Monitor With ECG Ultra Thin Seven Channel
Compact 8 In Multi Parameter Patient Monitor High Precision With Hooks
Product Specification
Payment Terms | T/T, Western Union, MoneyGram | Supply Ability | 30000units/year |
Delivery Time | Within 3 days | Packaging Details | Anti-collision film+ Carton box Carton box dimension: 40*30*35cm Gross weight: 6.30kg |
Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP | Weight | 3.55kg(with build-in two channel thermal printer) |
Size | 12.1 inch portable maternal fetal monitor | Voltage | 220v |
Power | 40w | Leads | 3-5 leads |
Suitable places | hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like. | Optional | mobile stand/wall mount |
Brand Name | RAINBOW | Model Number | PM-9000E |
Certification | ISO13485, FSC | Place of Origin | Hunan, China |
High Light | 9 Parameter Maternal Fetal Monitor ,Wifi Maternal Fetal Monitor ,FSC Medical Patient Monitor |
Basic information:
Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP |
Size | 12.1 inch portable maternal fetal monitor |
Weight | 3.55kg(with build-in two channel thermal printer) |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like. |
Optional | mobile stand/wall mount |
SFDA classification | Class II |
Working system | Continuous running equipment |
Features:
Support wired network and wifi, software online upgrade
new high-precision modules, new digital oxygen technology
12" color TFT display, up to 12 waveforms
3 in 1 transducers, no cable inter twisting.
Arrhythmia analysis, ST calculation, Pace analysis
Various interfaces: A single guide, standard, large font, all leads
Anti-ESU, anti- defibrillator
Patient info input management function
Multi-lead ECG waveforms display in phase
1-7 level audio/visual alarming
Large volume of tabular and graphic trends information storage and easy to recall
Built-in recorder and battery
suitable for adults, children, newborns and unborn babies.
Standard configuration:
PM-9000E maternal fetal monitor×1 set,
build-in dual channel thermal printer×1 set,
triple fetal probe×1 set,
ultrasound gel×1 bottom,
probe bandages×1 set,
standard 5-leads ECG conductance joint connecting cables×1 set,
standard adult blood pressure cuffs×1 set,
adult SPO2 probe×1 set,
TEMP probe×1 set,
power plug line×1 set,
grounding wire×1 set,
English operation manual×1 set.
Three certificates×1 set.
Optional:
Build-in rechargeable lithium battery; monitor mobile stand/ cart.
Technical Parameters
FHR | Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity. Ultrasound intensity: less than 1mW / cm² Operating frequency: 1.0MHz Signal Processing: dedicated digital signal processing unit Maximum Audio Output Power: 1.5W | TOCO
| 10-100 pressure unit
| |
Ultrasonic Probe Output
| In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ² | Coupling Agent (GEL)
| Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.
| |
ECG | lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable | NIBP | Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable | |
SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable | TEMP | Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable | |
RESP | Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable | Printer(Optional)
| Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. | |
System | Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
ECG | lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable | NIBP | Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable |
SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable | TEMP | Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable |
RESP | Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable | Printer(Optional)
| Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. |
System | Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
Company Details
Business Type:
Manufacturer,Trading Company,Seller
Year Established:
1997
Employee Number:
200~500
Ecer Certification:
Verified Supplier
Hunan Province Rainbow Technology is the professional medical equipment manufacturer in China, serving tons of hospitals, clinics , emergency centers and labs around the world. Hunan Province Rainbow Technology Co., Ltd has more than 26 years of experience in manufacturing and selling M... Hunan Province Rainbow Technology is the professional medical equipment manufacturer in China, serving tons of hospitals, clinics , emergency centers and labs around the world. Hunan Province Rainbow Technology Co., Ltd has more than 26 years of experience in manufacturing and selling M...
Get in touch with us
Leave a Message, we will call you back quickly!