Payment Terms | L/C, D/A, T/T, |
Delivery Time | 5-8 work days |
Packaging Details | 100PCs/Carton Carton Weight:5.5KG Carton Size:54*41*29CM |
Color | customized |
Certificate | ISO13485 |
Power | 2 *AAA 1.5V batteries |
Display | OLED display screen |
Power Consumption | Smaller than 30mA |
SpO2 Measuring Range | 0%- 100% |
Pulse Rate Measuring Range | 30 bpm - 250 bpm |
Material | ABS plastic |
Accuracy | ±2bpm or±2% select larger |
Automatic turn off | 5 seconds |
Net weight | 53g |
Gross weight | 86g |
Size | 85*66*40mm |
Model Number | ZLK-PO1 |
Place of Origin | China |
View Detail Information
Explore similar products
Blood Oxygen Saturation Finger Pulse Oximeter 250bpm
Handheld LED Fingertip Pulse Oximeter With Heart Rate Monitor wavelength 880nm
Fingertip Pulse Finger Heart Rate Monitor 50g
Large OLED Display Finger Pulse Oximeter Monitor SPO2 With Batteries
Product Specification
Payment Terms | L/C, D/A, T/T, | Delivery Time | 5-8 work days |
Packaging Details | 100PCs/Carton Carton Weight:5.5KG Carton Size:54*41*29CM | Color | customized |
Certificate | ISO13485 | Power | 2 *AAA 1.5V batteries |
Display | OLED display screen | Power Consumption | Smaller than 30mA |
SpO2 Measuring Range | 0%- 100% | Pulse Rate Measuring Range | 30 bpm - 250 bpm |
Material | ABS plastic | Accuracy | ±2bpm or±2% select larger |
Automatic turn off | 5 seconds | Net weight | 53g |
Gross weight | 86g | Size | 85*66*40mm |
Model Number | ZLK-PO1 | Place of Origin | China |
High Light | ISO13485 oxygen heart rate finger monitor ,250 bpm oxygen heart rate finger monitor ,Wrist Cord fingertip heart monitor |
Function Specification
Display Information | Display Mode |
The Pulse Oxygen Saturation(SpO2) | LED |
Pulse Rate(PR) | LED |
Pulse Intensity (bar -graph) | LED |
Pulse wave | LED |
SpO2 Parameter Specification | |
Measuring range | 0%~-100%, (the resolution is 1%). |
Accuracy | 70%~100%±2%, Below 70% unspecified. |
Optical Sensor | Red light (wavelength is 660nm) Infrared (wavelength is 880nm) |
Pulse Parameter Specification | |
Measuring range | 30bpm~250bpm (the resolution is 1 bpm) |
Accuracy | ±2bpm or±2% select larger |
Pulse Intensity | |
Range | Continuous bar-graph display, the higher display indicate the strong pulse |
Battery Requirement | |
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery | |
Battery Useful Life | |
Two batteries can work continally for 20 hours | |
Dimensions and Weight | |
Dimensions | 57(L) x 31(W) x 32(H) mm . |
Weight | About 50g (with the batteries) |
Environment Requirements
Storage Environment
a) Temperature :-40℃~+60℃
b) Relative humidity :<95%
c) Atmospheric pressure :500hPa~1060hPa
Operating Environment
a) Temperature :10℃~40℃
b) Relative Humidity :s75%
c) Atmospheric pressure :700hPa~1060hPa
1) Display Format: OLED Display;
SpO2 Measuring Range: 0%- 100%;
Pulse Rate Measuring Range: 30 bpm - 250 bpm;
Pulse Wave Display: columniation display and the waveform display.
2) Power Requirements: 2 x1.5V AAA alkaline battery(or using the rechargeable
battery instead), adaptable range: 2.6V~3.6V.
3) Power Consumption: Smaller than 30mA.
4) Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.
5) Measurement Accuracy: ±2% in stage of 70%-100% SpO2 , and meaningless
when stage being smaller than 70%.±2 bpm or±2% (select larger) for Pulse Rate.
6) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate
can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse
rate error is +2 bpm or±2% (select larger).
7) Resistance to surrounding light: The deviation between the value measured
in the condition of man-made light or indoor natural light and that of darkroom is
less than ±1%.
8) It is equipped with a function switch. The Oximeter can be powered off in case no
finger is the Oximeter within 5 seconds.
9) Optical Sensor
Red light (wavelength is 660nm, 6.65mW)
Infrared (wavelength is 880nm, 6.75mW)
Troubleshooting
Trouble | Possible Reason | Solution |
The SpO2 and Pulse Rate can not be displayed normally
| 1. The finger is not properly positioned. 2. The patient's SpO2 is too low to be detected.
| 1. Place the finger properly and try again. 2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right. |
The SpO2 and Pulse Rate are not displayed stably
| 1. The finger is not placed inside deep enough. 2. The finger is shaking or the patient is moving. | 1. Place the finger properly and try again. 2. Let the patient keep calm
|
The device can not be turned on
| 1. The batteries are drained or almost drained. 2. The batteries are not inserted properly. 3. The malfunction of the device. | 1. Change batteries. 2. Reinstall batteries. 3. Please contact the local service center.
|
The display is off suddenly
| 1. The device will power off automatically when it gets no signal within 5 seconds. 2. The batteries are almost drained. | 1. Normal. 2. Change batteries.
|
Company Details
Business Type:
Manufacturer
Year Established:
2020
Total Annual:
100M-1000M
Employee Number:
100~300
Ecer Certification:
Active Member
Hunan Zhongliankang Medical Technology Co., Ltd., subsidiary of Yufing Group, was founded in February, 2020, its manufacturing center is located in Jiuhua Economic Development Zone, Xiangtan, Hunan, China, covering an area of 4000 Square Meters. Equipped with international scientific R&D and pro... Hunan Zhongliankang Medical Technology Co., Ltd., subsidiary of Yufing Group, was founded in February, 2020, its manufacturing center is located in Jiuhua Economic Development Zone, Xiangtan, Hunan, China, covering an area of 4000 Square Meters. Equipped with international scientific R&D and pro...
Get in touch with us
Leave a Message, we will call you back quickly!