Material PVDF+UPVC
Pore Size 0.03um
ID/OD 1.0/2.0
Membrane Area 52m2
Water Flux 50-80LMH
Working Temperature 1-40C
Brand Name CNKHONG
Model Number KH-UF-8060W
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50pieces/day
Delivery Time 10 days Packaging Details wooden box
Material PVDF+UPVC Pore Size 0.03um
ID/OD 1.0/2.0 Membrane Area 52m2
Water Flux 50-80LMH Working Temperature 1-40C
Brand Name CNKHONG Model Number KH-UF-8060W
Place of Origin China
High Light 8 inch UF SystemPVDF material UF System200mm hollow fiber ultrafiltration membrane

8 inch Ultafiltration(UF) Membrane Modules for Purified Water Treatment with Pore Size 0.03um PVDF material

 

Ultrafiltration (UF) is another reliable and cost effective water treatment method.

This separation process is used in industry and research for purifying and concentrating macromolecular solutions, especially protein solutions with other applications including

  • Process and waste water treatment
  • Filtration of effluent from paper pulp mill
  • Cheese manufacture (using ultrafiltered milk)
  • Removal of some bacteria from milk
  • Fruit juice concentration and clarification
  • Laboratory grade manufacturing

The ultrafiltration membrane pore size creates a barrier to suspended solid, bacteria, colloids and viruses whilst still allowing passage of ions. As such, the mineral content of water passing through an ultrafiltration membrane does not appreciably change (further removal of mineral contact might be achieved through the use of Ion exchange resin treatments such as water softening, deionisation or demineralisation depending on the fuller scope of the process required).

UF membranes operate at much lower pressures than Reverse Osmosis (RO) membranes and require a higher degree of cross-flow to prevent plug fouling.

A more recent development in membrane technology, the cost of ultrafiltration membranes has reduced considerably in recent years, making it a much more effective cost option for a number of applications, including river extraction. Ultrafiltration is also often used as a very effective pre-treatment to reverse osmosis.

Typically employed in hollow fibre construction, operation of ultrafiltration membranes can be from outside-to-in (i.e. fed from outside the fibre with permeate collected from within) or inside-to-out, dependent upon the specific manufacturer and application. The robust construction of the fibres generally enables periodic back flushing of membranes to reduce plug fouling. The cleaning of membranes is also enhanced by the introduction of chemicals, such as sodium hypochlorite or sodium hydroxide, via a dedicated Clean in Place (CIP).


The structure as the following:2.2.2 type A of 8 inches UF module.

 

ab.png

 

 

 

 

Size and weight

 

Model KH-UF-8040W-PVDF KH-UF-8060W-PVDF
Module Diameter ( A, mm) Φ200 mm Φ200 mm
Module Length ( B, mm) 1220 mm 1640 mm
Module Length (C, mm) 1365 mm 1785 mm
Size of Inlet/Outlet DN50 DN50
Operating Type Outside to Inside Outside to Inside
Membrane Area 30 m2 45 m2
Dry weight of the module 20 Kg 35 Kg

 

 

 

 

 

Parameters

Shell material UPVC UPVC
Membrane Material PVDF PVDF
Membrane pore size 0.03μm 0.03μm
Inner diameter of the hollow fiber 0.7 mm 0.7 mm
Outer diameter of the hollow fiber 1.3mm 1.3mm
Turbidity of Permeating water ≤ 0.2NTU ≤ 0.2 NTU

SDI value of permeating water

 

≤ 3 ≤ 3

Flux rate for of purified water

(0.10MP,20℃)

≥ 3600L/H ≥ 5400L/H

 

 

 

 

Typical Process

 

Temperature Range 5-45 ℃ 5-45 ℃
PH Value Range 2-13 2-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr 40 -80 l/m2/hr
Operating Pressure ≤0.12 MPa ≤0.12MPa
Maximum Inlet Pressure 0.2 MPa 0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing times Once per 30-120 minutes Once per 30-120 minutes
Chemical cleaning online during backwashing Once per 7-14 days Once per 7-14 days


 

The whole installation and application process of our MBR modules are described as the following photo:

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2003

  • Ecer Certification:

    Verified Supplier

We,Hangzhou Kaihong Membrane Technology Co.,Ltd, is established on the year of 2003. We specializes in manufacturing UF and MBR membrane modules. We own more than 20 years of experience for the applying of UF and MBR membrane modules. Our products have been used in more than 1000 water treatment pla... We,Hangzhou Kaihong Membrane Technology Co.,Ltd, is established on the year of 2003. We specializes in manufacturing UF and MBR membrane modules. We own more than 20 years of experience for the applying of UF and MBR membrane modules. Our products have been used in more than 1000 water treatment pla...

+ Read More

Get in touch with us

  • Reach Us
  • Hangzhou Kaihong Membrane Technology Co., Ltd.
  • Bldg 10-1, # 11 Lingang Rd, Renhe Street, Yuhang Dist, Hangzhou, China
  • https://www.mbr-membranes.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement