China factories

China factory - Sichuan Vacorda Instruments Manufacturing Co., Ltd

Sichuan Vacorda Instruments Manufacturing Co., Ltd

  • China,Zigong ,Sichuan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display
China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display

  1. China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display
  2. China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display
  3. China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display
  4. China Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display

Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display

  1. MOQ: 1 Piece/Pieces
  2. Price: $150.00 - $350.00 / Pieces
  3. Get Latest Price
Supply Ability 200 Piece/Pieces per Month
Packaging Details wooden box
Product Name Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display Convertor
Medium Sewage, water, Conductive Liquid
Protection grade IP65 / IP 68(optional)
measuring range 50Pa~10MPa
Flow Totalizer 150:1
Connection size DN10~DN2400
Brand Name VACORDA
Model Number HKLD
Place of Origin Sichuan, China (Mainland)
Certification CE/TUV/ISO9001/SGS

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 200 Piece/Pieces per Month Packaging Details wooden box
Product Name Brass Water Electromagnetic Flow Meter Electromagnetic Flow Meter Display Convertor Medium Sewage, water, Conductive Liquid
Protection grade IP65 / IP 68(optional) measuring range 50Pa~10MPa
Flow Totalizer 150:1 Connection size DN10~DN2400
Brand Name VACORDA Model Number HKLD
Place of Origin Sichuan, China (Mainland) Certification CE/TUV/ISO9001/SGS
High Light electromagnetic water flow meterelectromagnetic flow sensor

Brass Water Electromagnetic Flow Meter Electro Magnetic Flowmeter

Electromagnetic flow meters, or magmeters, are comprised of a transmitter and sensor that together measure flow. The magnetic flow meter’s sensor is placed inline and measures an induced voltage generated by the fluid as it flows through a pipe. The transmitter takes the voltage generated by the sensor, converts the voltage into a flow measurement and transmits that flow measurement to a control system.

 

A magmeter utilizes a set of coils and a pair of electrodes for flow measurement. The meter’s coils are driven by the transmitter with an applied current. Once powered, a magnetic field is formed between both coils. When the pipe is full and the fluid begins to flow, the force of the magnetic field causes the negatively and positively charged particles of the fluid to separate as they pass through the magnetic field. This separation causes an induced voltage between the electrodes and sensor.

 

The flow principle behind magnetic flow meters is known as Faraday’s Law, mathematically defined as E=k*B*D*V. The induced voltage (E) is directly proportional to the velocity (V) of the fluid moving through the magnetic field (B). The induced voltage is carried to the transmitter through the electrode circuit. The transmitter then converts this voltage into a quantifiable flow velocity. The volumetric flow rate of the fluid is calculated using this known velocity along with the area of the pipe.

 

Magnetic flow meters are well suited for a variety of applications across a range of industries including pulp and paper, metals and mining, water and wastewater, food and beverage, chemical and petrochemical and oil and gas. Because the magnetic flow meter design does not leave any protrusions or obstructions in the pipe, they are able to accommodate an array of applications from clean and sanitary liquids to slurries and highly corrosive or abrasive fluids.

 

Features

1. There are no flowing and blocked flow parts in the pipeline of the 50mm water oil electromagnetic flow meter, and there is almost no additional pressure loss in the measurement.

2. The measurement result of the 50mm water oil electromagnetic flow meter has nothing to do with physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

3. The electromagnetic flowmeter uses a fast, high-precision 16-bit embedded processor to enhance the measurement stability.

4. The 50mm water oil electromagnetic flow meter has anti-interference and high reliability, and the measurement range is up to 150: 1.

5. The flowmeter adopts ultra-low EMI switch, and the power supply voltage range is wide.

 

Product Parameters

Product Name

Electromagnetic Flowmeter

Repeatability error

+/-0.1%

Accuracy class

0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c 

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow rate range

0.3~15m/s

Measured fluid conductivity

≥5μs/cm liquid

Output 

4~20mA / 4~20mA + Hart 

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy (H), 

Platinum (Pt) or other special electrode materials

Working power supply

85~265VAC / 24VDC / Battery

Straight pipe length

pipe: ≥ 5DN in the upper reaches, 

downstream of greater than or equal to 2DN

Connections

Flange

Protection grade

standard: IP65; IP68(optional)

Explosion-proof mark

mdllBT4 

 

Deatail Images

 

Precautions
1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields, so as to avoid the magnetic field affecting the working magnetic field of the sensor and the flow signal.
2. should be installed in a dry and ventilated place, to avoid sun and rain, the ambient temperature should be -20 ~ +60 ° C, relative humidity is less than 85%.
3. There should be plenty of space around the flowmeter for easy installation and maintenance.

 

Installation requirements
The measurement principle of the electromagnetic flowmeter is that it does not depend on the flow characteristics. If there is a certain turbulence and vortex inside the pipeline, it will be generated in the non-measurement zone (such as elbow, tangential current limit or half-opening shut-off valve upstream). Measurement is irrelevant. If steady-state eddy currents in the measurement zone affect the stability of the measurement and the accuracy of the measurement, then some measures should be taken to stabilize the flow rate distribution:
A. Increase the length of the straight pipe before and after.
B. Using a flow stabilizer.
C. Reduce a section of the measuring point.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1997

  • Total Annual:

    100W-150W

  • Employee Number:

    >150

  • Ecer Certification:

    Active Member

Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo... Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo...

+ Read More

Get in touch with us

  • Reach Us
  • Sichuan Vacorda Instruments Manufacturing Co., Ltd
  • No. 41, Chengxi Rd, Yantan industrial zone, Yantan dist., Zigong city, Sichuan province, China
  • https://www.magneticlevel-gauge.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement