China PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered
China PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered

  1. China PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered

PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered

  1. MOQ: 1 Piece/Pieces
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 300 Piece/Pieces per Month
Packaging Details Wooden box
Product Name Electromagnetic Flow Transmitter
Material 304,316L,321
Output signal 4-20mA/RS485/HART
Operating temperature -20 ~ +120 °C
Nominal diameter DN6-DN200
Pressure PN16-PN63
Viscosity 5~400mpa.s
Flange standard GB/T9112 GB/T 75
Port Shanghai/Shenzhen
Brand Name VACORDA
Model Number LWY/LYQ
Certification CE/TUV/ISO9001/SGS
Place of Origin Sichuan, China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 300 Piece/Pieces per Month Packaging Details Wooden box
Product Name Electromagnetic Flow Transmitter Material 304,316L,321
Output signal 4-20mA/RS485/HART Operating temperature -20 ~ +120 °C
Nominal diameter DN6-DN200 Pressure PN16-PN63
Viscosity 5~400mpa.s Flange standard GB/T9112 GB/T 75
Port Shanghai/Shenzhen Brand Name VACORDA
Model Number LWY/LYQ Certification CE/TUV/ISO9001/SGS
Place of Origin Sichuan, China (Mainland)
High Light PN63 Electromagnetic Flow TransmitterTUV Electromagnetic Flow Transmitter316L Battery Powered MAG Flow Sensor

PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered


Electromagnetic flow meters Widely used in flow measurement of petroleum, chemical, metallurgy, textile, paper, environmental protection, food and other industrial and municipal administration, water conservancy construction, river dredging and other fields.

Features
1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.
2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.
3. On-site modification of the measuring range available.
4. LCD display, easy to use and simple to operate.
5. Using SMD devices and SMT technology.
6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

Working Principle
Working principle of electromagnetic flow meter measurement is based on the Faraday law of electromagnetic induction. Measurements of the flow meter tube is lined with insulating material of a non-magnetic alloy spool. Two clicks along the diameter through-wall fixing on the measuring tube. The electrode head is flush with the lining inner surface. Field coil by waves when pulsed excitation by both parties, will be measured perpendicular
to the pipe axis direction produces a magnetic flux density of the magnetic field b. At this point, if you have
some electrical conductivity of fluid flows through the measuring tube, cut magnetic lines of induction electromotive force e.
Electromotive force e is proportional to the magnetic flux density B, measure the inside diameter d and the product of the mean velocity v. Electromotive force e (traffic signal) checked out by electrodes and cables to the converter. Converter after the traffic signal will be amplified, to display fluid flow and energy output pulse, analog current signals for flow control and the flow adjustment.
E=KBdv Type: E-for signal voltage between the electrodes (v)
B--magnetic flux density (t)
d--measuring tube diameter (m)
v--average flow velocity (m/s)
K, d is a constant, due to magnetizing current is constant, b is constant, the E=KBdv, is proportional to the
signal voltage and volumetric flow Q E-. And volume flow rate sensor signal voltage e Q into a linear relationship. Therefore, as long as the measure to determine the flow rate Q, this is the basic operating principle of electromagnetic flowmeter. By E=KBdv today, the measured flow of medium temperature, density, pressure, conductivity, liquid-solid two phase media of liquid and solid ingredients than parameter does not affect the measurement results.
As for the axisymmetric flow flow state as long as it meets (such as laminar or eddying flow) does not affect the measurement results. Thus volume flowmeter Electromagnetic Flowmeter is a real. For manufacturers and users alike, just use plain water after the actual calibration of measuring volume flow of the fluid any other to the point, without the need for human and remediation. This is electromagnetic flowmeter to highlight advantages, is not found in any other flow meters. Measuring tube and block parts of inactivity. So there is little pressure loss and extremely high reliability.


Product Parameters

Product Name Electromagnetic Flowmeter
Repeatability error +/-0.1%
Accuracy class 0.5 class, 1.0 class
Measured medium temperature Common rubber lining: -20~+60 ° c
High temperature rubber lining: -20~+90 ° c
PTFE lining: -30~+100 ° c
High temperature vinyl lining: -30~+180 ° c
Rated working pressure pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;
DN200~DN1200: ≤ 1.0MPa
Flow rate range 0.3~15m/s
Measured fluid conductivity ≥5μs/cm liquid
Output 4~20mA / 4~20mA + Hart
Electrode material 316L, titanium (Ti), tantalum (Ta), Hastelloy (H),
Platinum (Pt) or other special electrode materials
Working power supply 85~265VAC / 24VDC / Battery
Straight pipe length pipe: ≥ 5DN in the upper reaches, downstream
of greater than or equal to 2DN
Connections Flange
Protection grade standard: IP65; IP68(optional)
Explosion-proof mark mdllBT4


Deatail Images

 

Installation suggestion
1.To avoid magnetic field environment, and magnetic device, in case that it affects magnetic and signal output.
2. Dry and ventilated place for installation.
3.Avoid the sun and rain, and high temperature above 60℃ and humidity above 95%
4.Place that easy for installation and moving
5.Flowmeter should be installed behind pump, and valve must be connected with outflow part of flowmeter.

 

Installation requirement
1.Transmitter can be installed on the straight pipe and horizontal pipe
2.full pipe flow to avoid the electrode touching with air.
3.Vertical installation to abrade lining equally to prolong the lifetime, if the medium is mixture of liquid and water.
4.Change installation methods: choose smaller diameter flowmeter if the flow rate doesn't reach the requirement. Change Some part pipe to make diameter same as transmitter's, but straight pipe must be: inflow part≧ 5DN, outflow part≧2DN(DN pipe diameter)

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1997

  • Total Annual:

    100W-150W

  • Employee Number:

    >150

  • Ecer Certification:

    Active Member

Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo... Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo...

+ Read More

Get in touch with us

  • Reach Us
  • Sichuan Vacorda Instruments Manufacturing Co., Ltd
  • No. 41, Chengxi Rd, Yantan industrial zone, Yantan dist., Zigong city, Sichuan province, China